28
MR25664
MAINTENANCE
5.
Insert the new pick into the jaws of the extracting tool (pick puller) so that the raised pad
of the tool is pointing in the same direction as the pick point. See Figure #2
6.
Position the new pick in the pick holder on the drum and with a lead hammer or rubber-
headed mallet, hit the raised pad of the tool to start the pick into the pick holder. (Clean
out any foreign material from the pick holder before installing the new pick.)
7.
Once the pick is started into the pick holder strike the tool pad one strong blow to pop
the pick into the holder. See Figure #2
FIGURE #2
PICK
EXTRACTING
TOOL
PICK
HOLDER
The pick is properly seated when its shoulder is against the face of the pick holder.
Check to be sure the pick rotates freely. See Figure #3
FIGURE #3
CHANGING THE OIL IN THE GEARBOX
Planetary gearbox is to be half full of oil when the unit is mounted level and horizontal.
Use mild extreme pressure lubricant API-GL-5, No. 80 or 90. The capacity of the gearbox is
30 oz.
1.
Remove motor.
NOTE: Motor shaft adapter is loose and can fall from planetary.
2.
Remove pivot mount along with attachment, keep close and do not stretch hoses.
3.
Remove depth cylinders. Hydraulic lines can be left attached.
4.
Remove two skid retainers.
5.
Remove the planetary support & bearing mount from the frame. See Figure #1