Ausgabe 2011
ENGLISH 15
Maintenance work
The following maintenance work should be realised at the recommended intervals to increase the ser-
vice life of your compressor.
Monthly
Carry out visual inspection
Carry out a visual inspection of the unit once a month. Ensure in particular that no connections or
screws have loosened and examine the general condition of pressure hoses.
Draining condensate water from the tank
Note:
Condensate emerging from the unit should be removed with a suitable medium (e.g.
a cloth).
Drain condensate water from the tank once a month by releasing the drainage screw. The tank should
be under pressure during this procedure.
Open the drainage cock once for this purpose
(page 9, item 27)
Draining water from the water separator
Note:
Condensate emerging from the unit should be removed with a suitable medium (e.g.
a cloth).
Condensate water should be drained from the water separator once a month (or more often if neces-
sary).
Push the knob in, holding it depressed until the water has drained
out. After the water has been drained off loose the knob. The knob
close the water separator autonomous. The tank should be under
pressure during this procedure.
Technical data
The following is a table of performance values of individual compressor types.
Model
Voltage
Power
Suction
Pressure
Tank
Noise
Weight
capacity
capacity
level
net
Volt
Watt
litre
bar/psi
litre
dB (A) 1m
kg
MB-620
230/50
145
23-25
4/60
2.5
52-54
12