background image

Page 13

Page 12

Range Hood Operations

 (Continued)

Range Hood Operations

•  Controls:

•  Adjusting the timer function:

•  While the blower (motor) is not running, press and hold 

Decrease Value 

button over 3 seconds to 

enter timer mode. Adjust to desired period of delay off timer by pressing 

Increase Value 

or 

Decrease 

Value

 button (minimum 1 minute to maximum 9 minutes). This setting will be saved immediately.

•  Activating the timer function:

•  While the blower (motor) is running, press and hold 

Power 

button for over 3 seconds to activate 

delay off timer. 

Power-Off Delay Digital Timer

 begin to countdown, when it reaches zero, the blower 

(motor) will shut down.

•  Adjusting the light:

•  Press 

Light

 button once to turn on the lights, and once again to turn off the lights.

•  While the lights are off, press and hold 

Light

 button for over 3 seconds to dim the lights from high to 

low. Level of brightness will be stored in system’s memory.

CAUTION: DO NOT touch the lights until switched OFF and cooled.

Note: Light settings are independent from other settings (including power-off delay) and lights has to be 

manually turned on or off.

Note: The system saves user configurations, settings such as light, timer and blower (motor) speed will re-

main the same the next time it is turned on.

Power

Power-Off Delay

Decrease Value

Light

Increase Value

Blower Speed Indicator

Power-Off Delay Digital Timer

Cleaning Reminder Indicator

Control Panel Layout and Buttons Configurations:

Control Panel Layout and Buttons Configurations:

This range hood is designed to remove smoke, cooking vapors and odors from the cook top area.  For best results, 

start the range hood before cooking and allow it to operate several minutes after the cooking is completed to clear 

all smoke and odors from the kitchen.
•  Button functions:

•  Power: Power ON/OFF the range hood and activate power-off delay timer.

•  Decrease Value: Blower (motor) speed decrease, timer value decrease, and enter timer mode.

•  Increase Value: Blower (motor) speed increase, timer value increase, and cleaning reminder reset.

•  Blower Speed Indicator: Shows current blower (motor) speed (1-4 or 1-6).

•  Light: Turns ON/OFF and dim halogen lights.

•  Power-Off Delay Digital Timer: Indicates the length of time left for delay off function.

•  Controls:

•  Automatic cleaning reminder:

•  This range hood is equipped with a cleaning reminder that will activate following 30 hours of use. 

When blower (motor) starts to rotate, cumulative running time reached 30 hours then the 

Cleaning 

Reminder Indicator

 “C” flashes and reminds user to clean the aluminum filter.

•  After cleaning the filter and when the motor is not in use, press and hold 

Increase Value

 button over 3 

seconds to reset the timer. Please note that turning off the system will not reset the  

Power-On Elapsed 

Timer

.

•  Adjusting the blower (motor) speed:

•  Press 

Power

 button once to turn on the system. The 

Blower Speed Indicator

 shows the blower (mo

-

tor) speed level. 

Decrease Value

 button will decrease the speed of the blower (motor) from 4 or 6 to 1 

(strongest to quietest). 

Increase Value

 button will increase the speed of the blower (motor) from 1 to 

4 or 6 (quietest to strongest).

•  Press 

Power

 button once to turn off the system.

Note: The system saves user configurations, settings such as light, timer and blower (motor) speed will re-

main the same the next time it is turned on.

Power

Power-Off Delay

Decrease Value

Light

Increase Value

Blower Speed Indicator

Power-Off Delay Digital Timer

Cleaning Reminder Indicator

Summary of Contents for PS19

Page 1: ...nual Professional Built in hood Professional Insert Liners IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference Rev 2036u 1c Spagna Vetro PS19 ...

Page 2: ...rities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Ducted fans MUST always be vented to t...

Page 3: ...er and or distributor reseller further declines all responsibility for injury due to neg ligence and the warranty of the unit automatically expires due to improper maintenance The manufacturer and or distributor reseller will not be held responsible for any damages to per sonal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood Clean ventilating ...

Page 4: ...tant to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency It is recommended that the range hood be vented vertically through the roof through 8 20 3 cm or bigger round metal aluminum vent work Always use rigid type metal aluminum ducts if a...

Page 5: ...d mounting height above range Due to different ceiling height configurations recommended height may not be applicable Minimum Duct Size Round 8 minimum Rectangular 3 1 4 x 10 minimum requires a provided 3 1 4x10 adaptor Duct Run Calculation Recommended maximum run 8 or 3 1 4 x 10 duct 50 ft Vent piece deduction Each 90º elbow used 9 ft Each 45º elbow used 5 ft Each 8 to 3 14 x 10 transition used 7...

Page 6: ...Valley Road Cleveland Ohio 44131 5575 Advanced Preparations 1 Be familiar with the controls of the range hood by reading through Range Hood Operations Page 12 2 Place the range hood on a flat stable surface Connect the range hood to a designated standard outlet please refer the product label for the suitable voltage of this unit and turn on the range hood Verify all operations of the range hood by...

Page 7: ...al shock this range hood must be properly grounded Make sure this is done by qualified electrician in accordance with all applicable national and local electrical codes Before connecting wires switch power off at service panel and lock service panel to prevent power from being switched on accidentally 7 Connect the range hood to a designated standard outlet or cut off the plug and connect three wi...

Page 8: ...hood before cooking and allow it to operate several minutes after the cooking is completed to clear all smoke and odors from the kitchen Button functions Power Power ON OFF the range hood and activate power off delay timer Decrease Value Blower motor speed decrease timer value decrease and enter timer mode Increase Value Blower motor speed increase timer value increase and cleaning reminder reset ...

Page 9: ...arette ashes ignitable substances or any foreign objects into blowers NEVER leave cooking unattended When frying oil in the pan can easily overheat and catch fire The risk of self combustion is higher when the oil has been used several times NEVER cook on open flames under the range hood Check deep fryers during use Superheated oil may be flammable Cleaning The saturation of greasy residue in the ...

Page 10: ...ted from millimeters thus inch measurements are estimated Professional Insert Liner Wiring Diagram 4 Speed NOTE Wiring Diagrams shown above with GU10 light configuration A transformer is required for MR16 Lights Wiring Diagram 6 Speed Measurements Wiring Diagram Continued Measurements Wiring Diagram ...

Page 11: ...You must present proof of original purchase date Please provide an original dated proof of purchase sales receipt invoice in order to obtain service under warranty The information in this document is subject to change without notice please contact your local reseller for updated details Warranty SAFETY WARNING Never put your hand into area housing the fan while the fan is operating For optimal ope...

Page 12: ... A restocking fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchang es Service visits not covered under warranty ...

Page 13: ...Spagna Vetro Appliances Inc Burnaby BC Canada www KitchenHoods ca tel 604 430 5252 SPAGNA VETRO ...

Reviews: