background image

Installations

 (refer to Page 4 for parts)

:

Measure the distance between stove top and the bottom of 

range hood. A distance of 30” to 36” is recommended*.

*

Due to different ceiling height configurations, recommend-

ed height may not be applicable.

Installation of Metal Liner Inserts

1.  If the optional trim kit is used it must be installed prior to mounting the Metal Hood Liner into the wood 

decorative hood. Use the provided #8 Phillips head screws. See Figure 3.

2.  Lift the Metal Hood Liner into the decorative hood structure. Due to the weight of the assembly three people 

may be required for proper installation.

3. 

Install  #6  x  1/2”  screws  through  the  pre-drilled  EZ  mount  holes  into  the  decorative  hood  structure. Tap 

chrome cap into EZ mount holes for flush appearance See Figure 4.

4.  Additional mounting fasteners may be used to secure to the back wall and top (from inside).

 

CAUTION: Make certain the range hood is secure before releasing!

5. 

For safety purpose, pre-drilled mounting holes are provided through the back of the hood. For a more secure 

installation, use as many mounting holes as needed to secure from the inside of hood.

6. 

Use 8” round steel pipe (follow building codes in your area) to connect the exhaust on the hood to the duct

-

work above. Use silver tape or duct tape to make all joints secure and air tight. Refer to Figure 5.

SAFETY WARNING: Risk of electrical shock. this range hood must be properly grounded. Make sure this 

is done by qualified electrician in accordance with all applicable national and local electrical codes. Before 

connecting wires, switch power off at service panel and lock service panel to prevent power from being 

switched on accidentally.

7. 

Connect the range hood to a designated standard outlet or cut off the plug and connect three wires (black, 

white and green) to house wires and cap with wire connectors. Connect according to colors (i.e. black to 

black, white to white, and green to green) as shown in Figure 6.

8.  Store excess wires in the wiring box.

9. 

Drop oil tunnel into recess support near rear of hood. Refer to Figure 7.

Page 11

Installation

Figure 4

Wood Hood

Mounting Holes

Figure 3

Screew

Trim Kit

Installation

 (Continued)

Figure 7

Figure 6

Figure 5

Figure 8

10.  To install baffle filters and stainless spacer(s), refer to 

Baffle Filters and Stainless Steel Spacers

 on Page 23 for baffle 

filter and stainless spacer placement. Refer to Figure 8 for the following five steps:

Angle baffle filter toward back of hood.

Push baffle filter up until almost level.

Slide forward into recess behind the front of hood.

Lower baffle filter.

Slide back until it fits into resting positions.

11. Repeat Step 8 to install all baffle filters and stainless spacers.

12. OPTIONAL: Install heating lamps (not included) last. 220V or 120V (for USA & Canada), 250-Watt 

maximum per lamp.

13. Turn powe ON in control panel. Check all lights and fan operations.

14. Make sure to leave this Installation Guide for the homeowner.

Page 10

Summary of Contents for PS19

Page 1: ...nual Professional Built in hood Professional Insert Liners IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference Rev 2036u 1c Spagna Vetro PS19 ...

Page 2: ...rities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Ducted fans MUST always be vented to t...

Page 3: ...er and or distributor reseller further declines all responsibility for injury due to neg ligence and the warranty of the unit automatically expires due to improper maintenance The manufacturer and or distributor reseller will not be held responsible for any damages to per sonal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood Clean ventilating ...

Page 4: ...tant to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency It is recommended that the range hood be vented vertically through the roof through 8 20 3 cm or bigger round metal aluminum vent work Always use rigid type metal aluminum ducts if a...

Page 5: ...d mounting height above range Due to different ceiling height configurations recommended height may not be applicable Minimum Duct Size Round 8 minimum Rectangular 3 1 4 x 10 minimum requires a provided 3 1 4x10 adaptor Duct Run Calculation Recommended maximum run 8 or 3 1 4 x 10 duct 50 ft Vent piece deduction Each 90º elbow used 9 ft Each 45º elbow used 5 ft Each 8 to 3 14 x 10 transition used 7...

Page 6: ...Valley Road Cleveland Ohio 44131 5575 Advanced Preparations 1 Be familiar with the controls of the range hood by reading through Range Hood Operations Page 12 2 Place the range hood on a flat stable surface Connect the range hood to a designated standard outlet please refer the product label for the suitable voltage of this unit and turn on the range hood Verify all operations of the range hood by...

Page 7: ...al shock this range hood must be properly grounded Make sure this is done by qualified electrician in accordance with all applicable national and local electrical codes Before connecting wires switch power off at service panel and lock service panel to prevent power from being switched on accidentally 7 Connect the range hood to a designated standard outlet or cut off the plug and connect three wi...

Page 8: ...hood before cooking and allow it to operate several minutes after the cooking is completed to clear all smoke and odors from the kitchen Button functions Power Power ON OFF the range hood and activate power off delay timer Decrease Value Blower motor speed decrease timer value decrease and enter timer mode Increase Value Blower motor speed increase timer value increase and cleaning reminder reset ...

Page 9: ...arette ashes ignitable substances or any foreign objects into blowers NEVER leave cooking unattended When frying oil in the pan can easily overheat and catch fire The risk of self combustion is higher when the oil has been used several times NEVER cook on open flames under the range hood Check deep fryers during use Superheated oil may be flammable Cleaning The saturation of greasy residue in the ...

Page 10: ...ted from millimeters thus inch measurements are estimated Professional Insert Liner Wiring Diagram 4 Speed NOTE Wiring Diagrams shown above with GU10 light configuration A transformer is required for MR16 Lights Wiring Diagram 6 Speed Measurements Wiring Diagram Continued Measurements Wiring Diagram ...

Page 11: ...You must present proof of original purchase date Please provide an original dated proof of purchase sales receipt invoice in order to obtain service under warranty The information in this document is subject to change without notice please contact your local reseller for updated details Warranty SAFETY WARNING Never put your hand into area housing the fan while the fan is operating For optimal ope...

Page 12: ... A restocking fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchang es Service visits not covered under warranty ...

Page 13: ...Spagna Vetro Appliances Inc Burnaby BC Canada www KitchenHoods ca tel 604 430 5252 SPAGNA VETRO ...