Inverter Air-to-Water Heat Pump
Failure Interface
1. When failure occurs, press the ‘Failure’ icon on the upper right corner to access the failure logging display.
2. A total of 35 sets of historical failures can be recorded, display and record them in reverse order. The latest record is always
shown on the top line.
3. When there is no failure, the failure notice will not read on the interface.
4. When failure occurs
a. The failure icon will be flashing alternately between ‘ ’ and ‘ ’.
b. The failure interface will record the failure code, failure name and the time of the failure.
c. Press ‘Clear’ button to delete the failure record, then the unsolved failure will be shown on the record again, at the same
time the failure icon on the main interface will continue to flash as an alarm.
5. After failure clean up
a. If the failure display is uncheck, the icon will not be shown on the interface.
b. The failure record will keep the failure code, failure name and the time of the failure.
c. Press ‘Clear’ button to delete the failure record, the resolved failure will not be shown on the failure record.
6. The failure record is provided with power-off memory function, if the record is deleted manually, they will not be shown again in
the record.
Screen Inspection
1. Click the area on the lower right corner on the loaded condition display for continuously 10 clicks in 4 seconds to access the
screen inspection display.
2. The screen inspection display contains 40 touch control button which are white during accessing, then turn to be green and emit
‘bee’ alarm when clicked.
3. When the last touch control button (on the lower right corner) is clicked for the second time, or when the operating time on the
display (automatically calculated from entrance time) accumulated to 1 minute, the control exit of the screen inspection display.
4. The follow situation will be considered as exception, when one touch control point on the screen is pressed but no ‘bee’ alarm
emitting and the responding area have not turned green, or when one touch control is clicked and other irrelevant area turn
green.
Return
Error code
Error
Page up
Page
Malfuncti
on current
time
Error
Return
Error code
Error
Page up
Page
Malfuncti
on current
time
Error
Return
Error code
Error
Page up
Page
Malfuncti
on current
time
Error