Pathfinder SL v1.9 Operations Manual
3-4
Generic Paced
P
Extended Classifications
Atrial Paced
aP
Aberrated Normal
A
Ventricular Paced
vP
Bundle Branch Block
B
Dual Paced
dP
Left Bundle Branch Block
LBB
Unclassified
Q
Right Bundle Branch Block
RBB
Removed
r
WPW
WPW
Calibration
C
Fusion
F
Note:
It is possible for an operator to use the same letter on more than one beat type, however
the operator is warned if they enter a duplicate label. The warning can be overridden.
Note:
Removed trigger beats are only displayed in the Morphologies screen.
3.8
Saving Settings
Preferred settings for arrhythmia analysis, ECG scan and ECG display can be stored for future/
default use. Settings can be saved as named “Setups” using the Setup Manager accessed from the
Manage Setups menu. A “Setup” can be stored as a Global or a Local setup.
The Setup Manager has three groupings of setup:
Factory Setups
–
contains the Factory Default Setup which cannot be modified or deleted.
Global Setups
–
contains setups visible to all Pathfinder SL analyzers connected to the same
Sentinel network. This includes the special “New Analysis Setup” which is
the initial default for all Pathfinder SL analyzers
Local Setups
–
contains setups that are only visible to this analyzer. These setups can only
be modified from the Pathfinder SL analyzer that created them.
The default setup that is being used by the system for a new analysis has the label (default) and is
highlighted in blue.
Factory Setups.
Factory Default Setup
This setup is built in to the Pathfinder SL application, and cannot be modified or deleted. It contains
the initial settings used by Pathfinder SL when first installed.
Global Setups
These are setups that are visible to and can be used by all Pathfinder SL systems on the network.
Setups from one Pathfinder SL analyzer can be saved as Global setups to make them available to
other Pathfinder SL analyzers in a Sentinel network.
New Analysis Setup
On initial installation, this setup is the same as the Factory Default setup and is used as the default
named Setup for ALL PASL analyzers. Because this named Setup is known to All Pathfinder SL
analyzers it can be used to define a standardized setup to be used by ALL Pathfinder SL Analyzers
in a Sentinel network UNLESS an individual analyzer defines its own default.
Summary of Contents for 98000
Page 4: ...Pathfinder SL v1 9 Operations Manual iv This page is intentionally blank...
Page 16: ...Pathfinder SL v1 9 Operations Manual 1 6 This page is intentionally blank...
Page 34: ...Pathfinder SL v1 9 Operations Manual 4 8 This page is intentionally blank...
Page 42: ...Pathfinder SL v1 9 Operations Manual 5 8 This page is intentionally blank...
Page 46: ...Pathfinder SL v1 9 Operations Manual 6 4 This page is intentionally blank...
Page 50: ...Pathfinder SL v1 9 Operations Manual 7 4 This page is intentionally blank...
Page 56: ...Pathfinder SL v1 9 Operations Manual 8 6 This page is intentionally blank...
Page 62: ...Pathfinder SL v1 9 Operations Manual 9 6 This page is intentionally blank...
Page 72: ...Pathfinder SL v1 9 Operations Manual 12 2 This page is intentionally blank...
Page 78: ...Pathfinder SL v1 9 Operations Manual 14 4 This page is intentionally blank...
Page 96: ...Pathfinder SL v1 9 Operations Manual 17 4 This page is intentionally blank...
Page 114: ...Pathfinder SL v1 9 Operations Manual 19 6 This page is intentionally blank...
Page 120: ...Pathfinder SL v1 9 Operations Manual 20 6 This page is intentionally blank...
Page 121: ......