SPACECAM
SYSTEMS, INC.
MAXIMUS 7 OPERATOR’S MANUAL
August 17, 2016
The analog voltages meant to be working with analog lenses. They set up the voltages for the LimeRock
Lens Control Interface outputs. The maximum range is Low: 0.0V to High: 10.0V. It is the operators
responsibility to make sure that Low is less than High and the voltages will not destroy the controlled lens
drive.
The “Zero” is for velocity mode. Only the zoom has velocity mode. Set the Zero in the middle of the Low-
High range and the analog command to the zoom will be velocity not position.
The “Init current” values are proportional to the initializing torque (commanded current) of the
corresponding function (zoom, focus and iris). At power-up each axis will be moved one way and then the
other to mark the end of the mechanical range. Set the current values for the lens that it can overcome
friction but won’t hit the end of range too hard.
Cmotion option
For wired setup use the
USER
interface on the
console and saddle on the platform to connect the
hand unit to the driver. We can make the
connecting cables for you on request.
SpaceCam is working on integrating the Cmotion
controller with the Maximus system.
31240 La Baya Dr. Ste. A
Westlake Village, CA. 91362
818-889-6060
Page 26 of 74