3.2.2
LPG - G30/G31 at 29/37mbar supply pressure (appliance cat 3+).
Maximum supply pressure (Pmax) G30 - 35mbar
G31 - 45mbar
Minimum supply pressure (Pmin) G30 - 20mbar
G31 - 25mbar
Note:- for appliances cat 3+, the governor is not operational.
Gas connection: Rc - ½.
3.2.2.1 The appliance should be connected to a permanent piped supply of LPG, with pipes of adequate size to
achieve a gas supply pressure between the maximum and minimum valves stated above, measured at the
appliance inlet pressure test point.
3.2.3
The complete installation MUST be tested for soundness in accordance with National or Local Regulations.
3.3
Electrical Supply
WARNING:
APPLIANCES EMPLOYING DIRECT BURNER SPARK IGNITION
MUST
BE EARTHED.
APPLIANCES EMPLOYING PILOT IGNITION
MUST NOT
BE CONNECTED TO ANY ELECTRICAL
SUPPLY
3.3.1
Direct Burner Spark Ignition: the electrical wiring to the appliance must be installed in accordance with the latest
or current National Regulations and any Local Regulations which apply.
Electrical supply 230v ~ 50Hz 25W
Current rating
0.11A
Fuse externally
3A
3.3.2
Twin core and earth PVC covered flexible supply cable (0.5mm
2
- to National or Local standard specification)
must be used, with connections made as shown in Fig. 3.
3.3.3
SRP30 Hi/Lo models only.
Three core and earth PVC covered flexible supply cable (0.5mm
2
- to National or Local standard specification)
must be used, with connections made as shown in Fig. 4.
SRP 08, 15, 22 & 30
Fig.3
THERMOSTAT SWITCH
THERMOSTAT SWITCH
HEATER 1
HEATER 2
GREEN/YELLOW
BLUE
BROWN
7
N
L
7
7
SINGLE HEATER PER THERMOSTAT
7
L
N
HEATER 1
7
MULTIPLE HEATERS PER THERMOSTAT
SWITCH
BROWN
BLUE
GREEN/YELLOW
HEATER 2
7
SWITCH
THERMOSTAT