Form 43343530
Aug 2012
-41-
18.0)
LIGHTING AND SHUTDOWN INSTRUCTIONS
SIDE VIEW
43269050 Rev. A 03/08
DANGER
Failure to do so may result in death,
serious injury or property damage
FIRE HAZARD
This access panel must be closed
tightly with all the necessary screws
during operation.
Never operate the heater with the
access panel open or removed.
Failure to do so may result in death, serious injury or property
damage.
The access doors on either side of the burner must
be securely fastened before operating the heater.
The access panels must be closed tightly with all the necessary
screws during operation.
Never operate the heater with the access panel open or removed.
1.
Turn on the gas and electrical supply. Rotate the gas valve knob counter-clockwise
to the “ON” position.
2.
Set the thermostat to call for heat. The blower motor will energize.
3.
Ignition should occur after the 15-second pre-purge.
4.
If the burner fails to light, or flame is not detected during the first trial for ignition (a period of approximately
15 seconds) the gas valve is de-energized and the control goes through an inter-purge delay of
approximately 60 seconds before another ignition attempt. The control will attempt two additional ignition
trials before going into lockout, and the valve relay will be de-energized immediately. The blower will be
turned off following a post-purge period of approximately 30 seconds.
5.
If the heater does not light, manually reset the thermostat or shut off power completely for 5 minutes before
attempting to relight.
6.
To permanently shut down the heater, rotate the gas valve knob clockwise
to the “OFF” position and turn
off the gas and electrical supply.
NOTE: T
NOTE: T
NOTE: T
NOTE: The lighting and shutdown instructions are als
he lighting and shutdown instructions are als
he lighting and shutdown instructions are als
he lighting and shutdown instructions are also shown on the permanent nameplate label attached to the
o shown on the permanent nameplate label attached to the
o shown on the permanent nameplate label attached to the
o shown on the permanent nameplate label attached to the
heater control box.
heater control box.
heater control box.
heater control box.