16
(Red) (Yellow) (Green) (White)
Explanation:
0
°
nozzle setting – A pinpoint stream. This nozzle stream is very powerful and covers a very small area of
cleaning. Only to be used on surfaces that can withstand this high pressure (metal or concrete).
15
°
to 25
°
nozzle setting – Used for less powerful stream which can cover a wider area. This nozzle setting is
also very powerful and should only be used on surfaces that can withstand this high pressure.
40
°
nozzle setting – Used for the least powerful stream and covers a wide area of cleaning. This nozzle setting
should be used for most general cleaning jobs.
Pressure Adjustment:
The maximum working pressure is pre-set at the factory and can not be overridden. By turning the pressure
adjustment knob anti-clockwise you can reduce both the pressure and water volume being supplied from the
pump.
Low Pressure Detergent Operation:
The Black Tip – will lower the pressure and allow chemical to be drawn through
the downstream chemical injector.
•
Change the high pressure nozzle for the Detergent (Black) Nozzle.
(Be sure the quick coupler is fully engaged before pulling the trigger)
•
The chemical injector will only work when this (black) nozzle is used.
•
Push the ¼” clear plastic hose to the inlet barb of the chemical
injector located near the high pressure hose connection (item 8,
page 2).
•
Insert the loose end of the detergent pick up hose into the
desired chemical.
Be sure to flush the injection system with clean water after use.
•
Place the chemical injector hose in a bucket of clean water and
operate for one minute.