3-16
Safety instructions
R
The tool and gear wagon GW-1 is the optimum solution for
☞
installing SOYER stud welders and for properly storing welding
pistols, cables, studs, retrofit kits etc.
• Make sure stud welder cannot be used by unauthorized personnel.
• Turn energy range controller (item 4, chapter 5.1) to the left till stop (smallest
energy value).
• Check welding cable and connections of the stud welder for damages such
as burn-off, mechanical wear etc. and have damaged parts replaced by
SOYER customer service.
3.13.2 Stopping the stud welder when welding with optional automatic
operation
• Close the shut-off valve of the compressed air supply.
• Activate the pistol switch several times until the pressure in the lines drops
completely.
• Disconnect the compressed air supply connections at the rear side (item 18
and 19, chapter 5.1) and at the front side (item 8 and 9, chapter 5.1).
• Disconnect the interface plug from the connecting socket (item 14, chapter
5.1) at the rear side of the stud welder.
• Disconnect the plug of the universal feeder from the connecting socket at
the rear side of the stud welder (item 15, chapter 5.1).
• Continue as described in chapter 3.13.1.
3.14 The "S" symbol
The "S" symbol is the symbol for welding current sources permitted for opera-
tion with increased electric danger. The "S" symbol on our stud welders refers
exclusively to the welding current circuit and not to the complete stud welder.