32
VMN LOW
AL30
Await for
traction
Motor
output
voltage is lower
than ideal value
Valve
、
pump motor
,
Traction electric machine is
stopped
,
Master
contactor
is
disconnection,
electromagnetic braking
start
Request
of
valve
、
lift or
traction.
VMN HIGH
AL31
Await for
traction
Motor
output
voltage is higher
than ideal value
Valve
、
pump motor
,
Traction electric machine is
stopped
,
Master
contactor
is
disconnection,
electromagnetic braking
start
Request
ofvalve
、
lift or
traction
POWER
MOS
SHORTED
AL7*
Await for
traction
Power
MOS
shorted
Valve
、
pump motor
,
Traction electric machine is
stopped
,
Master
contactor
is
disconnection,
electromagnetic braking
start
Request
ofvalve
、
lift or
traction
COIL
SHORT
HW KO
Hardware
failureAL7
5
Await for
traction
Hardware
circuit
fault
with
short-circuit
protection of main
contactor
and
EMBR coil
Valve
、
pump motor
,
Traction electric machine is
stopped
,
Master
contactor
is
disconnection,
electromagnetic braking
start
Request
ofvalve
、
lift or
traction
COIL
SHORTED
AL76
Await for
traction
Main contactor or
braking
coil
shorted
Valve
、
pump motor
,
Traction electric machine
stopped
,
Master
contactor
is
disconnection,
electromagnetic braking
Static
state
、
traction
Request
ofvalve
、
lift or
traction
DRIVER
SHORTED
AL74
Await for
traction
Main contactor coil
driving
shorted,shouldn’t
turn-off the main
contactor.
Valve
、
pump motor
,
Traction electric machine
stopped
,
Master
contactor
is
disconnection,
electromagnetic braking
Start
、
Static
state
、
traction
Request
ofvalve
、
lift or
traction
CONTACT
OR
DRIVER
AL75
Await for
traction
Main contactor coil
driving damaged
(main contactor
cannot close)
Valve
、
pump motor
,
Traction electric machine
stopped
,
Master
contactor
is
disconnection,
electromagnetic braking
Static
state
、
traction
Request
ofvalve
、
lift or
traction