17
Specifications cont.
60.00nF
600.0nF
6.000µF
60.00µF
600.0µF
6000µF
Input Protection:
600V DC or 600V AC rms
* Accuracy is not stated below 6nF
10pF
0.1nF
1nF
10nF
0.1µF
1µF
±(5.0% +30 digits)*
±(3.0% +5 digits)
±(3.0% +5 digits)
±(3.0% +5 digits)
±(4.0% +10 digits)
±(4.5% +10 digits)
Capacitance
(Autoranging)
Function
Range
Resolution
Accuracy
±
(
% of r digits)
6.000Hz
60.00Hz
600.0Hz
6.000kHz
60.00kHz
600.0kHz
10.00MHz
Input Protection:
600V DC or 600V AC rms
Sensitivity:
>5V AC rms
0.001Hz
0.01Hz
0.1Hz
1Hz
10Hz
100Hz
0.01MHz
±(1.0% +5 digits)
±(1.0% +5 digits)
±(1.0% +5 digits)
±(1.0% +5 digits)
±(1.0% +5 digits)
±(1.0% +5 digits)
±(1.0% +5 digits)
Frequency
(Autoranging)
Function
Range
Resolution
Accuracy
±
(
% of r digits)
Frequency through test leads when meter is set to Hz %
600.0
Ω
6.000k
Ω
60.00k
Ω
600.0k
Ω
6.000M
Ω
60.00M
Ω
Input Protection:
600V DC or 600V AC rms
0.1
Ω
1
Ω
10
Ω
100
Ω
1k
Ω
10k
Ω
±(1% +4 digits)
±(1.5% +2 digits)
±(1.5% +2 digits)
±(1.5% +2 digits)
±(2.0% +5 digits)
±(3% +8 digits)
Resistance
(Autoranging)
Function
Range
Resolution
Accuracy
±
(
% of r digits)
18
Specifications cont.
10Hz to 10kHz
20% to 80%
Input Protection:
1000V AC rms or 1000V DC
Duty Cycle Sensitivity: 10Hz to 1kHz
Sensitivity:
>15V AC rms
±1.0% ±5 digits
±1.5% ±10 digits
Frequency
(Autoranging)
Duty Cycle
Function
Range
Accuracy
(
% of r digits)
Frequency through test leads when meter is set to AC voltage
40Hz to 1kHz
20% to 80%
±1.0% ±5 digits
±1.5% ±10 digits
Frequency
(Autoranging)
Duty Cycle
Function
Range
Accuracy
(
% of r digits)
Frequency through jaws when meter is set to AC current
Maximum Input: 1000A AC rms or 1000A DC
Duty Cycle Sensitivity: 10Hz to 1kHz
Sensitivity:
>50A (600A range)
>500A (1000A range)
-4 to 1400°F
-20° to 760°C
Input Protection:
600V DC or 600V AC rms
Sensor:
Type K Thermocouple
0.1°F/1°F
0.1°C /1°C
±3% ±9°F
±3% ±5°C
Temperature
Function
Range
Resolution
Accuracy
±
(
% of r digits)
0.5% to 99.9%
Input Protection:
600V DC or 600V AC rms
Pulse Width:
100µS to 100mS
Frequency:
10Hz to 10kHz
Sensitivity:
>5V RMS
0.1%
±(1.2% +10 digits)
Duty Cycle
Function
Range
Resolution
Accuracy
±
(
% of r digits)
Duty Cycle through test leads when meter is set to Hz%