Southwire 41161N Operating Instructions Manual Download Page 3

General Specifications

4

Insulation
Display 
DC Polarity

Over Range Indication
Continuity 

Low Battery Indication

Measurement Rate
Auto Power Off

Input Impedance
AC Response
AC Bandwidth
Battery:  
Operating Temperature
Storage Temperature
Relative Humidity

Operating Altitude
Weight

Dimensions:
Safety:

Class 2, Double insulation.
LED
Automatic.    “+“ / “-“ is displayed for polarity

Buzzer
Audible indication if the resistance is 
approximately 10K

Ω

 or less

POWER LED will flash when battery voltage is too 
low for normal operation
3 times per second, nominal
Meter automatically shuts down after approx. 
15 minutes of inactivity
AC/DC voltage: 

10M

Ω

Average responding 
50/60Hz
Two AAA batteries 
32°F to 122°F (0°C to 50°C) 
14°F to 122°F (-10°C to 50°C)
Maximum, non-condensing: 95% up to 82°F (28°C), 
75% to 104°F (40°C), 45% to 122°F (50°C)
0-2000 meters
5 ounces (142 grams) includes 2-AAA batteries, 
not including test leads
6.3” x 2.2” x 1.4” (160 x 55 x 35mm)
UL: 61010 - 1:2012, 61010-2-030: 2012, 
61010-2-033: 2014
EMC

EN61326-1:2013, EN61326-2-2:2013

3

International Safety Symbols

Potential danger. Indicates the user must refer to the

manual for important safety information.
Indicates hazardous voltages may be present

Equipment is protected by double or reinforced insulation

Indicates the terminal(s) so marked must not be connected to a circuit where

the voltage with respect to earth ground exceeds the maximum safety rating

of the meter .
Indicates the terminal(s) so marked may be

subjected to hazardous voltages.

MAX

600V

The measurement category (CAT) rating and voltage rating is determined by a combination of the meter,  
the test probes and any accessories connected to the meter and test probes. The combination rating is the
LOWEST rating of any individual component

 Description

Typical Applications

Category

Rating

Single phase receptacles

and connected loads 

Three phase circuits and

single phase lighting

circuits in commercial

buildings 

- Household appliances, power tools

- Outlets more than 30ft (10m) from a CAT III source

- Outlets more than 60ft (20m) from a CAT IV source
- Equipment in fixed installations such as 3-phase

   motors, switchgear and distribution panels 

- Lighting circuits in commercial buildings

- Feeder lines in industrial plants

- Any device or branch circuit that is close to a CAT III source

CAT II

CAT III

Connection point to utility 
power and outdoor 
conductors

- Primary distribution panels
 - Overhead or underground lines to detached buildings
 - Incoming service entrance from utility
 - Outdoor pumps

CAT IV

Safety Category Ratings 

Summary of Contents for 41161N

Page 1: ......

Page 2: ...DC 600V AC RMS 400V DC Read understand and follow the safety rules and operating instructions in this manual before using this tester The tester s safety features may not protect the user if not used...

Page 3: ...voltages may be present Equipment is protected by double or reinforced insulation Indicates the terminal s so marked must not be connected to a circuit where the voltage with respect to earth ground e...

Page 4: ...o or television receiving antenna Increase the separation between the computer equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the radio or televi...

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...not detect voltage if o The detector tip cannot be fully inserted into the electrical outlet o The outlet is a Tamper Resistant TR design o The user is not holding the voltage tester o The user s han...

Page 9: ......

Page 10: ...screw Be careful not to over tighten the screw Replacing the Battery To avoid electric shock remove test leads from the voltage tester before removing the battery cover WARNING To avoid electric shoc...

Page 11: ...nsurance and packaging costs associated with sending a product to Southwire Southwire will not be responsible for lost or damaged products returned pursuant to this warranty All products returned to S...

Page 12: ...rne le risque potentiel d arc lectrique Il est important de lire de comprendre et de respecter les r gles de s curit et les instructions d utilisation contenues dans ce manuel avant d utiliser ce test...

Page 13: ...ent est prot g par une isolation double ou renforc e Indique que la ou les bornes ainsi marqu es ne doivent pas tre connect es un circuit o la tension par rapport la mise la terre d passe la cote de s...

Page 14: ...rf rences nuisibles dans une installation r sidentielle Cet quipement g n re et peut mettre de l nergie de fr quence radio S il n est pas install et utilis selon les instructions il peut produire des...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ...e bo te de m tal ou dans un conduit m tallique mis la terre o L op rateur n est pas reli la terre ou est isol d une mise la terre efficace o La tension est CC Le d tecteur pourrait ne pas d tecter la...

Page 19: ......

Page 20: ...act ristiques EN MODE D TECTEUR DE TENSION CA SANS CONTACT tapes de tension DEL Niveau de s curit Gamme de fr quences CA Temp rature de fonctionnement Temp rature de stockage Humidit relative Altitude...

Page 21: ...crire pour vous inscrire Cliquez ensuite sur Enregistrer le produit pour enregistrer votre produit Southwire Company LLC garantit ce produit contre tout d faut de mat riel et de fabrication pendant ci...

Page 22: ...de arco el ctrico Lea comprenda y siga las reglas de seguridad y las instruc ciones de operaci n de este manual antes de utilizar este probador Las medidas de seguridad del probador podr an no proteg...

Page 23: ...el voltaje con respecto a la conexi n a tierra es superior al m ximo indicado por la clasificaci n de seguridad del medidor Indica que las terminales as marcadas pueden estar sujetas a voltajes peligr...

Page 24: ...azonable contra interferencias da inas en una instalaci n residencial Este equipo genera utiliza y puede irradiar energ a de radiofrecuencia y si no se instala y utiliza seg n las instrucciones puede...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...uitos energizados o El cable est blindado o en un conducto o caja de metal con conexi n a tierra o El operador no est conectado a tierra o est aislado de una toma de tierra efectiva o El voltaje es CC...

Page 29: ......

Page 30: ...ficaciones MODO DE DETECTOR DE VOLTAJE DE CA SIN CONTACTO Etapas LED de distinto voltaje Clasificaci n de seguridad Rango de frecuencia de CA Temperatura de operaci n Temperatura de almacenamiento Hum...

Page 31: ...registrar Despu s de registrarse haga clic en Registrar producto para registrar el producto Southwire Company LLC garantiza que este producto estar libre de defectos materiales y de mano de obra duran...

Reviews: