Southwire 21005N Operating Instructions Manual Download Page 2

2

Introduction

1

 

WARNINGS

The Southwire 21005N clamp meter is an electrical test tool 

that combines a digital multimeter with an AC current sensor.  

The hinged jaw on the clamp meter is the current sensor.  

When electrical current flows through a wire, a magnetic field 

is generated around the wire.  The current sensor detects and 

measures this magnetic field.

A clamp meter is a convenient test & measurement tool 

because it allows a technician to measure the current in a wire 

at any point in an electrical system without having to discon-

nect the wire or deenergize the circuit.

The Southwire 21005N clamp meter measures AC current up 

to 200A and offers a CAT III 600V safety rating. Other 

functions include AC and DC voltage, resistance, continuity, 

and diode test. This meter is fully tested and calibrated and, 

with proper use, will provide many years of reliable service. 

• Read, understand and follow Safety Rules and Operating 

   Instructions in this manual before using this meter.

• The meter’s safety features may not protect the user if not 

   used in accordance with the manufacturer’s instructions. 

• Ensure that the test leads are fully seated in the input jacks 

   and keep fingers behind the finger guards when taking 

   measurements.

• Before changing functions using the selector switch, always 

   disconnect the test leads from the circuit under test.

• Use only UL listed test leads with the proper safety 

   category rating.  

• Comply with all safety codes. Use approved personal 

   protective equipment when working near live electrical  

   circuits - particularly with regard to arc-flash potential.

• Use caution when working on or near bare conductors or 

   bus bars. 

• Use caution on live circuits. Voltages above 30 V AC RMS, 

   42 V AC peak, or 60 V DC pose a shock hazard.

• Do not use meter or test leads if either appears damaged.

• Do not use the meter in wet or damp environments or 

   during electrical storms.

• Do not use the meter near explosive vapors, dust, or 

   gasses.

• Do not use the meter if it operates incorrectly. Protection 

   may be compromised. 

• Do not operate meter while Low Battery warning is on. 

   Replace the batteries immediately.

• Verify meter’s operation by measuring known voltage. 

• Do not apply voltage or current that exceeds the meter’s 

   maximum rated input limits.

10A

CATIII600V

Finger Guard

Summary of Contents for 21005N

Page 1: ...manuel Contents Made in China Fabriqu en Chine Product distributed by Produit distribu par Southwire Company LLC One Southwire Drive Carrollton GA 30119 2016 Southwire Company LLC All rights reserved...

Page 2: ...f not used in accordance with the manufacturer s instructions Ensure that the test leads are fully seated in the input jacks and keep fingers behind the finger guards when taking measurements Before c...

Page 3: ...Equipment is protected by double or reinforced insulation Indicates the terminal s so marked must not be connected to a circuit where the voltage with respect to earth ground exceeds the maximum safet...

Page 4: ...ER GENTLY AND CAREFULLY Dropping it can damage the electronic parts or the case 4 KEEP THE METER CLEAN Wipe the case occasionally with a damp cloth DO NOT use chemicals cleaning solvents or detergents...

Page 5: ...LCD display 6 COM input jack 7 V input jack Volts Amperes Alternating current Direct current Minus sign Ohms Continuity Diode test micro 10 6 milli 10 3 kilo 103 mega 106 Overload Auto Power Off Low...

Page 6: ...p meter is an auto ranging meter which means that the meter automatically selects the most appropriate measurement range for the testing that is being conducted Auto ranging is the default mode for th...

Page 7: ...t lead into the V input jack 3 Touch the test lead probes to the circuit under test Touch the red test lead to the positive side of the circuit and the black test lead to the negative side of the circ...

Page 8: ...ce will indicate OL in both polarities Diode Test Never test resistance on a live circuit WARNING Never test diodes on a live circuit WARNING 14 Operation cont 13 Continuity Test Never test continuity...

Page 9: ...Install the battery cover and tighten the screw Do not overtighten the screw Function Range Resolution Accuracy of reading 20 00A 200 0A All ranges are specified for a sinewave from 10 to 100 of rang...

Page 10: ...roduct and no such reseller warranty will be binding on Southwire If you have a warranty claim or if the product needs to be serviced during or after the warranty period set forth above please contact...

Page 11: ...manuel Contents Made in China Fabriqu en Chine Product distributed by Produit distribu par Southwire Company LLC One Southwire Drive Carrollton GA 30119 2016 Southwire Company LLC All rights reserved...

Page 12: ...ri e Respectez tous les codes de s curit Utilisez un quipe ment de protection individuelle approuv lorsque vous travaillez proximit de circuits lectriques sous tension en particulier en ce qui concern...

Page 13: ...ode Test de continuit Indication de piles faibles Taux de mesure Arr t automatique Imp dance d entr e R ponse CA Bande passante CA Piles Temp rature de fonctionnement Temp rature de rangement Humidit...

Page 14: ...endant il n existe aucune garantie que de telles interf rences ne se produiront pas dans une installation particuli re Si cet quipement cause des interf rences nuisibles la r ception radio ou t l visu...

Page 15: ...d entr e COM 7 Prise d entr e V v Volts Amp res Courant alternatif Courant continu Signe moins Ohms Continuit Test de diode micro 10 6 milli 10 3 kilo 103 mega 106 Surcharge Arr t automatique Indicat...

Page 16: ...de mesure commutation automatique de gamme ce qui signifie que l appareil de mesure s lectionne automatiquement la gamme de mesure la plus appropri e pour les essais en cours La s lection automatique...

Page 17: ...e V 3 Touchez les sondes du fil d essai sur le circuit soumis au test Touchez le fil d essai rouge sur le c t positif du circuit et le fil d essai noir sur le c t n gatif du circuit 4 Lisez la tension...

Page 18: ...dans les deux polarit s Test de diode Ne testez jamais la r sistance sur un circuit sous tension AVERTISSEMENT Ne testez jamais les diodes dans un circuit sous tension AVERTISSEMENT 14 Operation cont...

Page 19: ...hiffres Tension alternative Commutation automatique de gamme Tension continue Commutation automatique de gamme Courant alternatif R sistance Commutation automatique de gamme 1 0 8 chiffre 20 00 A 2 00...

Page 20: ...e tout d faut de mat riel et de fabrication pendant cinq ans compter de la date d achat La pr sente garantie ne couvre pas les fusibles ni les piles jetables ni les dommages r sultant d un accident d...

Page 21: ...05N manual manuel Contents Made in China Fabriqu en Chine Product distributed by Produit distribu par Southwire Company LLC One Southwire Drive Carrollton GA 30119 2016 Southwire Company LLC All right...

Page 22: ...eguridad Use equipo de protecci n personal aprobado cuando trabaje cerca de circuitos el ctricos energizados particularmente con respecto al potencial de arco el ctrico Tenga cuidado cuando trabaje en...

Page 23: ...en de continuidad Indicaci n de bater a baja Tasa de medici n Apagado autom tico Impedancia de entrada Respuesta de CA Ancho de banda de CA Bater a Temperatura de funcionamiento Temperatura de almacen...

Page 24: ...embargo no hay garant a de que no se produzcan interferencias en una instalaci n en particular En caso de que este equipo provocara interferencia da ina en la recepci n de radio o televisi n lo que s...

Page 25: ...Toma de entrada COM 7 V Toma de entrada Voltios Amperes Corriente alterna Corriente continua Signo menos Ohmios Continuidad Prueba de diodo micro 10 6 milli 10 3 kilo 103 mega 106 Sobrecarga Apagado a...

Page 26: ...lo que significa que el medidor selecciona autom ticamente el rango de medici n m s apropiado para la prueba que se est realizando El rango autom tico es el modo predeterminado para el medidor de pinz...

Page 27: ...n la toma de entrada V 3 Toque las puntas de prueba del circuito que se est probando Toque el cable de prueba rojo con el lado positivo del circuito y el cable de prueba negro con el lado negativo del...

Page 28: ...indicar OL en ambas polaridades Prueba de diodo Nunca pruebe la resistencia en un circuito energizado ADVERTENCIA Nunca pruebe los diodos en un circuito energizado ADVERTENCIA 14 Operacion 13 Examen...

Page 29: ...ctura d gitos 2 5 9 d gitos 1 5 5 d gitos Voltaje de CA Rango autom tico Voltaje de CC Rango autom tico Corriente de CA Resistencia Rango autom tico 1 0 8 d gitos 20 00 A 2 000 V 20 00 V 200 0 V 600 V...

Page 30: ...rrecta contaminaci n modificaci n uso indebido mantenimiento o reparaci n operaci n fuera de las especificaciones o manejo anormal del producto La nica responsabilidad de Southwire y el recurso exclus...

Reviews: