Southwire 16040T Operating Instructions Manual Download Page 5

10 A

16040T

MAX

MIN

MODE

10 A

16040T

MAX

MIN

MODE

8

1. Set the rotary function 

    switch to the 

    position. 

2. Insert the black test lead 

    into the 

COM

 input jack and 

    the red test lead into 

    the 

V

 input jack. 

3. Touch the test lead probes 

    to the circuit under test.

4. Read the voltage on the LCD display.

AC Voltage Measurements 

   Observe all safety precautions

when working on live voltages.

WARNING:  

Operation cont.

V

V

-

+

1. Set the rotary function switch 

    to the 

V

  position. 

2. Insert the black test lead into the 

    

COM

 input jack and the red test 

    lead into the 

V

 input jack. 

3. Touch the test lead probes to 

    the circuit under test. Touch the 

    red test lead to the positive side 

    of the circuit and the black test 

    lead to the negative side of the circuit.

4. Read the voltage on the LCD display.

DC Voltage Measurements 

   Observe all safety precautions

when working on live voltages.

WARNING:  

10 A

16040T

MAX

MIN

MODE

10 A

16040T

MAX

MIN

MODE

7

Operation

MODE Button

Used to select AC voltage, Frequency or % Duty Cycle, AC or DC current, and Ohms, 

Diode Test, Continuity or Capacitance.

MAX/MIN Button

1. Momentarily press the 

MAX/MIN

 button to activate the MAX/MIN mode. “

MAX

” 

    will appear on the LCD display and the meter will display and hold the highest 
    reading. The meter will update the reading when a higher “max” occurs.
2. Momentarily press the 

MAX/MIN

 button again to view the lowest reading. 

    “

MIN

” will appear on the LCD display and the meter will display and hold the 

    lowest reading. The meter will update the reading when a lower “min” occurs. 
3. Press and hold the 

MAX/MIN

 button to end MAX/MIN and return to normal 

    operation. 

  NOTE:

 MAX/MIN does not work on Frequency, Duty Cycle, Resistance, 

  Continuity, Diode Test and Capacitance. 

FLASHLIGHT / Bluetooth

®

 Button

Bluetooth

®

 wireless technology allows readings to be displayed and stored on 

mobile devices. To activate, press and hold the          button until the "    " symbol 

appears on the LCD display. The Bluetooth

®  

function should be disabled when not 

connected to a mobile device in order to conserve battery power. To turn the 

Bluetooth

®  

function off, press and hold the          button until the "    " symbol no 

longer appears on the display.
Visit nextgenmeters.southwiretools.com for mobile app download information.
To turn the flashlight on and off, momentarily press the          button. 

HOLD/Backlight button 

To freeze the reading on the LCD display, momentarily press the 

HOLD

     button. 

The “     ” indicator will be displayed while the reading is being held. Momentarily 

press the 

HOLD

     button again to return to normal operation.

The backlight illuminates the LCD display when the ambient light is too low to view 

the displayed readings. To turn the backlight on, press the 

HOLD

     button until the 

backlight turns on. To turn the backlight off, press the 

HOLD

     button until the 

backlight turns off.

H

Summary of Contents for 16040T

Page 1: ...A 30119 2016 Southwire Company LLC All rights reserved Tous droits r serv s southwiretools com 1 855 SW T00LS Toll Free Technical Help Assistance technique gratuite L nea de Ayuda T cnica Gratuita Las...

Page 2: ...as take measurements from a safe distance Visit nextgenmeters southwiretools com for mobile app download information Functions include AC DC voltage and current resistance continuity capacitance freq...

Page 3: ...subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device...

Page 4: ...capacitance nano 10 9 micro 10 6 milli 10 3 kilo 103 mega 106 Overload Auto Power Off Low battery Autoranging Display hold Maximum Minimum Bluetooth Technology 10A 16040T MAX MIN MODE 5 Meter Descript...

Page 5: ...ccurs 2 Momentarily press the MAX MIN button again to view the lowest reading MIN will appear on the LCD display and the meter will display and hold the lowest reading The meter will update the readin...

Page 6: ...AC DC set the rotary function switch to the mA position and insert the red test lead into the mA input jack 4 For current measurements up to 4000 A AC DC set the rotary function switch to the A posit...

Page 7: ...ad the resistance in on the LCD display Resistance Measurements Never test resistance on a live circuit WARNING 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE 10A 16040T MAX M...

Page 8: ...w on the fuse cover 2 Remove the fuse cover 3 Gently remove fuse and install new fuse into the holder 4 Always use a UL recognized fuse of the proper size and value 500mA 600V 5 x 20mm fast blow for t...

Page 9: ...ange Input Protection 600V RMS or 600V DC Accuracy is given at 65 F to 83 F 18 C to 28 C less than 70 relative humidity 1mV 10mV 0 1V 1V 1 0 5 digits 1 2 5 digits AC Voltage 50 60Hz Function Range Res...

Page 10: ...ifications or abnormal handling of the product Southwire s sole liability and the purchaser s exclusive remedy for any breach of this warranty is expressly limited to Southwire s repair or replacement...

Page 11: ...nt de l application mobile Les fonctions du multim tre incluent la mesure d intensit s et de tensions CA CC la mesure de r sistances la v rification de la continuit la mesure de capacit s la mesure de...

Page 12: ...une installation particuli re Si cet quipement provoque effectivement des interf rences nuisibles la r ception de la radio ou de la t l vision ce qu on peut d terminer en teignant et rallumant l quipe...

Page 13: ...i 10 3 kilo 103 mega 106 Surcharge Extinction automatique Pile faible S lection automatique de calibre Maintien de l affichage Valeur maximum minimum BluetoothMD 10A 16040T MAX MIN MODE 5 Description...

Page 14: ...au bri vement sur le bouton MAX MIN pour afficher la valeur la plus basse L indicateur MIN s affiche alors sur l cran LCD aux c t s de la valeur la plus basse Le multim tre actualise la valeur d s qu...

Page 15: ...connecteur d entr e mA 4 Pour mesurer des courants inf rieurs 4000 A CA CC tournez le s lecteur rotatif la position A puis branchez la sonde rouge dans le connecteur d entr e mA 5 Enfoncez le bouton M...

Page 16: ...RTISSEMENT Ne testez jamais une diode sur un circuit sous tension AVERTISSEMENT 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE Tension directe Tension inverse Sonde rouge Sonde rouge Sonde noire Sond...

Page 17: ...OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OPENING CASE OR FUSE COVER F10A 600V WARNING F500mA 600V Fonctionnement suite 1 Retirez la vis Phillips sur le co...

Page 18: ...pulsion 100 s 100 ms Largeur de fr quence de 5 Hz 150 kHz Sensibilit 1 V RMS Fonction Plage R solution Pr cision de lecture nombre de chiffres Fonction Plage R solution Pr cision de lecture nombre de...

Page 19: ...NE AUCUNE AUTRE GARANTIE TANT EXPLICITE QU IMPLICITE AUTRE QUE CELLES MENTIONN ES LA PR SENTE SOUTHWIRE NE POURRA PAS TRE TENUE RESPONSABLE D VENTUELS DOMMAGES INCIDENTS CONS CUTIFS INDIRECTS SP CIAUX...

Page 20: ...uthwiretools com para obtener informaci n sobre descargas de aplicaciones m viles Las funciones incluyen voltaje y corriente AC DC resistencia continuidad capacidad frecuencia ciclo de trabajo y prueb...

Page 21: ...salida si dicha funci n est disponible Cumple con las Normas de IDA DA107392 Mantenimiento Este Mult metro est dise ado para proporcionar a os de servicio confiable si se llevan a cabo las siguientes...

Page 22: ...nterna Bluetooth 1 2 4 5 6 8 9 7 3 6 S mbolos Utilizados en la Pantalla LCD V A AC DC Hz F n m k M OL AUTO MAX MIN H Voltios Amperios Corriente alterna Corriente continua Signo de menos Hertz frecuenc...

Page 23: ...Presione moment neamente el bot n de MAX MIN nuevamente para ver la lectura m s baja MIN aparecer en la pantalla LCD y el probador indicar y retendr la lectura m s baja El probador actualizar la lect...

Page 24: ...l cable de prueba rojo en la toma de entrada mA 4 Para medidas de corriente hasta 4000 A AC DC ajuste el interruptor de funci n rotativa a la posici n de A e inserte el cable de prueba rojo en la toma...

Page 25: ...en un circuito vivo ADVERTENCIA 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE SONDA SONDA SONDA SONDA Roja Negra Negra Roja Prueba de avance Prueba de retroceso 10A 16040T MAX MIN MODE 10A 16040T M...

Page 26: ...REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OP...

Page 27: ...5V 400Hz a 4000Hz Funci n Rango Resoluci n Precisi n de lectura d gitos 20 0 a 80 0 Protecci n de Entrada 600V RMS o 600V DC 0 1 1 2 5 d gitos Ancho de banda del del Ciclo de Trabajo 100us 100 ms Anc...

Page 28: ...R SOUTHWIRE NO HACE NINGUNA OTRA GARANT A EXPRESA O IMPL CITA SALVO QUE LA GARANT A ESPEC FICAMENTE MENCIONADA EN ESTE DOCUMENTO SOUTHWIRE NO SER RESPONSABLE DE DA OS INCIDENTALES CONSECUENCIALES INDI...

Reviews: