Fonction                                      Plage                        Résolution               Précision ± (% de l nombre de chiffres)

  

Fonction                                      Plage                        Résolution               Précision ± (% de l nombre de chiffres)

40,00 nF
400,0 nF
4,000 µF
40,00 µF
400,0 µF
4000 µF

Protection d’entrée :  

250 V RMS ou 250 VCC 

 

10 pF
0,1 nF
0,001 µF
0,01 µF
0,1 µF
1 µF

±(5,0 % +35 chiffres)

±(3,0 % +5 chiffres)

±(4,0 % +5 chiffres)

 

±(5,0 % +5 chiffres)

Capacité

400,0 

Ω

4,000 k

Ω

40,00 k

Ω

400,0 k

Ω

4,000 M

Ω

40,00 M

Ω

Protection d’entrée :  

250 V RMS ou 250 VCC

 

0.1 

Ω

Ω

10 

Ω

100 

Ω

1 k

Ω

10 k

Ω

±(1,0 % + 4 chiffres)

±(1,5 % +5 chiffres)

±(3,5 % +5 chiffres)

Résistance

18

GARANTIE LIMITÉE ET RESTRICTIONS DE RESPONSABILITÉ À 

L’ÉGARD DES APPAREILS DE MESURE VENDUS PAR SOUTHWIRE

Southwire Company, LLC garantit ce produit contre tout défaut de matière ou 

de fabrication pendant une période de deux ans à partir de la date de l’achat. 

Cette garantie ne couvre cependant pas les fusibles, les piles non recharge-

ables, ainsi que les dommages résultant d’un accident, d’une utilisation 

incorrecte ou négligente, de la contamination, de la modification du produit, 

d’un entretien inapproprié, d’une réparation inappropriée, d’une utilisation en 

dehors des spécifications, ou de toute manipulation anormale du produit. 

Pour tout incident entrant dans le cadre de la présente garantie, la respon-

sabilité de Southwire envers l’acheteur est de réparer ou de remplacer le 

produit en cause. La décision de réparer ou de remplacer le produit 

défectueux est du ressort exclusif de Southwire.

SOUTHWIRE N’OFFRE AUCUNE GARANTIE QUE LES PRODUITS SOIENT DE 

QUALITÉ MARCHANDE OU ADÉQUATE POUR UNE UTILISATION PARTICU-

LIÈRE. SOUTHWIRE NE DONNE AUCUNE AUTRE GARANTIE, TANT EXPLICITE 

QU’IMPLICITE, AUTRE QUE CELLES MENTIONNÉES À LA PRÉSENTE. 

SOUTHWIRE NE POURRA PAS ÊTRE TENUE RESPONSABLE D’ÉVENTUELS 

DOMMAGES INCIDENTS, CONSÉCUTIFS, INDIRECTS, SPÉCIAUX OU 

PUNITIFS DÉCOULANT DU NON-RESPECT DE CETTE GARANTIE.

Cette garantie ne s’applique pas si le produit est acquis à des fins de 

location. Aucun revendeur de ce produit n’est autorisé à étendre la portée de 

cette garantie au nom de Southwire et, s’il le fait, Southwire ne sera pas liée 

par un tel engagement. Si vous voulez faire une réclamation au titre de la 

garantie ou si le produit a besoin d’une intervention pendant la période de 

garantie ou après son expiration, veuillez contacter le Service à la clientèle 

Southwire au 855-SWTOOLS (855 798-6657).

L’expéditeur est responsable des frais d’expédition, de transport, d’assurance 

et d’emballage associés au retour du produit chez Southwire. Southwire 

n’assume pas de responsabilité à l’égard des pertes ou des dommages subis 

par les produits retournés dans le cadre de la présente garantie.

Tous les produits retournés à Southwire dans le cadre de cette garantie 

doivent être adressés à :

Southwire Company, LLC

Attention: Tool Warranty Return

840 Old Bremen Road

Carrollton, GA 30117, É.-U.

ENREGISTREMENT DU PRODUIT

Enregistrez le produit que vous venez d’acheter en allant sur 

www.southwiretools.com.

Southwire s’engage à vous fournir le meilleur service possible. 

L’enregistrement ne vous prendra que quelques minutes et vous permettra de 

bénéficier d’un service plus rapide, d’un soutien plus personnalisé et d’une 

information en avant-première sur nos futurs produits. Il vous suffit pour cela 

de nous donner le modèle et le numéro de série du produit, ainsi que quelques 

renseignements sur vous-même – c’est à la fois simple et rapide.

Summary of Contents for 16040T

Page 1: ...A 30119 2016 Southwire Company LLC All rights reserved Tous droits r serv s southwiretools com 1 855 SW T00LS Toll Free Technical Help Assistance technique gratuite L nea de Ayuda T cnica Gratuita Las...

Page 2: ...as take measurements from a safe distance Visit nextgenmeters southwiretools com for mobile app download information Functions include AC DC voltage and current resistance continuity capacitance freq...

Page 3: ...subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device...

Page 4: ...capacitance nano 10 9 micro 10 6 milli 10 3 kilo 103 mega 106 Overload Auto Power Off Low battery Autoranging Display hold Maximum Minimum Bluetooth Technology 10A 16040T MAX MIN MODE 5 Meter Descript...

Page 5: ...ccurs 2 Momentarily press the MAX MIN button again to view the lowest reading MIN will appear on the LCD display and the meter will display and hold the lowest reading The meter will update the readin...

Page 6: ...AC DC set the rotary function switch to the mA position and insert the red test lead into the mA input jack 4 For current measurements up to 4000 A AC DC set the rotary function switch to the A posit...

Page 7: ...ad the resistance in on the LCD display Resistance Measurements Never test resistance on a live circuit WARNING 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE 10A 16040T MAX M...

Page 8: ...w on the fuse cover 2 Remove the fuse cover 3 Gently remove fuse and install new fuse into the holder 4 Always use a UL recognized fuse of the proper size and value 500mA 600V 5 x 20mm fast blow for t...

Page 9: ...ange Input Protection 600V RMS or 600V DC Accuracy is given at 65 F to 83 F 18 C to 28 C less than 70 relative humidity 1mV 10mV 0 1V 1V 1 0 5 digits 1 2 5 digits AC Voltage 50 60Hz Function Range Res...

Page 10: ...ifications or abnormal handling of the product Southwire s sole liability and the purchaser s exclusive remedy for any breach of this warranty is expressly limited to Southwire s repair or replacement...

Page 11: ...nt de l application mobile Les fonctions du multim tre incluent la mesure d intensit s et de tensions CA CC la mesure de r sistances la v rification de la continuit la mesure de capacit s la mesure de...

Page 12: ...une installation particuli re Si cet quipement provoque effectivement des interf rences nuisibles la r ception de la radio ou de la t l vision ce qu on peut d terminer en teignant et rallumant l quipe...

Page 13: ...i 10 3 kilo 103 mega 106 Surcharge Extinction automatique Pile faible S lection automatique de calibre Maintien de l affichage Valeur maximum minimum BluetoothMD 10A 16040T MAX MIN MODE 5 Description...

Page 14: ...au bri vement sur le bouton MAX MIN pour afficher la valeur la plus basse L indicateur MIN s affiche alors sur l cran LCD aux c t s de la valeur la plus basse Le multim tre actualise la valeur d s qu...

Page 15: ...connecteur d entr e mA 4 Pour mesurer des courants inf rieurs 4000 A CA CC tournez le s lecteur rotatif la position A puis branchez la sonde rouge dans le connecteur d entr e mA 5 Enfoncez le bouton M...

Page 16: ...RTISSEMENT Ne testez jamais une diode sur un circuit sous tension AVERTISSEMENT 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE Tension directe Tension inverse Sonde rouge Sonde rouge Sonde noire Sond...

Page 17: ...OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OPENING CASE OR FUSE COVER F10A 600V WARNING F500mA 600V Fonctionnement suite 1 Retirez la vis Phillips sur le co...

Page 18: ...pulsion 100 s 100 ms Largeur de fr quence de 5 Hz 150 kHz Sensibilit 1 V RMS Fonction Plage R solution Pr cision de lecture nombre de chiffres Fonction Plage R solution Pr cision de lecture nombre de...

Page 19: ...NE AUCUNE AUTRE GARANTIE TANT EXPLICITE QU IMPLICITE AUTRE QUE CELLES MENTIONN ES LA PR SENTE SOUTHWIRE NE POURRA PAS TRE TENUE RESPONSABLE D VENTUELS DOMMAGES INCIDENTS CONS CUTIFS INDIRECTS SP CIAUX...

Page 20: ...uthwiretools com para obtener informaci n sobre descargas de aplicaciones m viles Las funciones incluyen voltaje y corriente AC DC resistencia continuidad capacidad frecuencia ciclo de trabajo y prueb...

Page 21: ...salida si dicha funci n est disponible Cumple con las Normas de IDA DA107392 Mantenimiento Este Mult metro est dise ado para proporcionar a os de servicio confiable si se llevan a cabo las siguientes...

Page 22: ...nterna Bluetooth 1 2 4 5 6 8 9 7 3 6 S mbolos Utilizados en la Pantalla LCD V A AC DC Hz F n m k M OL AUTO MAX MIN H Voltios Amperios Corriente alterna Corriente continua Signo de menos Hertz frecuenc...

Page 23: ...Presione moment neamente el bot n de MAX MIN nuevamente para ver la lectura m s baja MIN aparecer en la pantalla LCD y el probador indicar y retendr la lectura m s baja El probador actualizar la lect...

Page 24: ...l cable de prueba rojo en la toma de entrada mA 4 Para medidas de corriente hasta 4000 A AC DC ajuste el interruptor de funci n rotativa a la posici n de A e inserte el cable de prueba rojo en la toma...

Page 25: ...en un circuito vivo ADVERTENCIA 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE SONDA SONDA SONDA SONDA Roja Negra Negra Roja Prueba de avance Prueba de retroceso 10A 16040T MAX MIN MODE 10A 16040T M...

Page 26: ...REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OP...

Page 27: ...5V 400Hz a 4000Hz Funci n Rango Resoluci n Precisi n de lectura d gitos 20 0 a 80 0 Protecci n de Entrada 600V RMS o 600V DC 0 1 1 2 5 d gitos Ancho de banda del del Ciclo de Trabajo 100us 100 ms Anc...

Page 28: ...R SOUTHWIRE NO HACE NINGUNA OTRA GARANT A EXPRESA O IMPL CITA SALVO QUE LA GARANT A ESPEC FICAMENTE MENCIONADA EN ESTE DOCUMENTO SOUTHWIRE NO SER RESPONSABLE DE DA OS INCIDENTALES CONSECUENCIALES INDI...

Reviews: