background image

Congratulations! You have just purchased one of the fmest pieces of heavy-duty, commercial cooking 
equipment on the market today.

 

You will find that your new equipment, like all Southbend equipment, has been designed and manufactured to 
some of the toughest standards in the industry  — those of Southbend Corporation. Each piece of Southbend 
equipment has been carefully engineered and designs have been verified through laboratory tests and field 
installations in some of the more strenuous commercial cooking applications. With proper care and field 
maintenance, you will experience years of reliable, trouble-free operation from your Southbend equipment. To get 
the best results, it's important that you read this manual carefully. 

TABLE OF CONTENTS:

 

SECTION ONE - INSTALLATION

 

Specifications ........................................................... l

 

Installation ...........................................…................ 2

 

SECTION TWO - USER'S GUIDE

 

Warranty...............................................…......……... l

 

Operation .................................................…......…... 2

 

Maintenance ............................................................. 3

 

SECTION THREE - SERVICE

 

Adjustments .........................................………......... l

 

Service............................................................……... 2

 

Trouble Shooting ...................................................... 3

 

SECTION FOUR - PARTS

 

Parts List .....................................................……....…. 1

 

Southbend Infra-Red Broilers are unique in design. They incorporate our exclusive Schwank ceramic tile burners, which 
generate infra-red rays that provide better quality products in about one-half the usual broiling time, with less gas input than 
ordinary broilers. Very little energy is wasted in heating secondary surfaces, as is necessary in conventional-type broilers.

 

Since the surface of these tiles become red hot in less than one-half minute, the unit is ready to start broiling with a very short 
preheat time, thereby saving time, labor and energy.

 

These glowing surfaces emit intense infra-red rays, which are transmitted directly onto the product, thereby yielding better 
tasting broiled food in less time.

 

Use of 100% clean primary air, which is constantly conveyed to these burners, insures efficient combustion and maintains full 
production capacity and maximum recovery, even in the most severe conditions of grease vapors and smoke atmospheres, 
which are created during any broiling process.

 

The Southbend Infra-Red Broilers provide such speed and recovery that broiling techniques may require some modification in 
order to take full advantage of its productive capabilities.

 

CAUTION: 

POST IN PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT 

THE SMELL OF GAS IS DETECTED. THIS INFORMATION SHALL BE OBTAINED FROM 
LOCAL GAS SUPPLIER. 

NOT INTENDED FOR HOUSEHOLD USE. FOR COMMERCIAL USE ONLY.

 

Retain this manual for future reference. 

FOR YOUR SAFETY 

 

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE

 

VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER

 

APPLIANCE.

 

 
 

KEEP AREA AROUND APPLIANCES FREE AND CLEAR FROM

 

COMBUSTIBLES.

 

 

IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN EQUIP

 

MENT AT THE MAIN SHUTOFF VALVE AND CONTACT THE LOCAL

 

GAS COMPANY OR GAS SUPPLIER FOR SERVICE.

 

 

1100 Old Honeycutt 
Road Fuquay-Varina. 
NC 27526 (919)552-
9161 FAX (919) 552-
9798 (800)348-2558

 

 

Summary of Contents for MRA-32

Page 1: ...e installation of commercial gas and or electrical cooking equipment then the terms and conditions of the Manufacturer s Limited Warranty will be rendered void and no warranty of any kind shall apply...

Page 2: ...l type broilers Since the surface of these tiles become red hot in less than one half minute the unit is ready to start broiling with a very short preheat time thereby saving time labor and energy The...

Page 3: ...leby Co shall not be liable for consequential or special damages of any nature that may arise in connection with such product or part Should service be required at times which normally involve overtim...

Page 4: ...ly disappear and within two minutes the ceramics will glow red The flame on the surface of the ceramics should be barely visible with little or no blue haze 4 LOW SETTING After the burner has operated...

Page 5: ...tion of the polished lines will not mar the finish of the stainless steel NEVER RUB WITH A CIRCULAR MOTION Soil and burnt deposits which do not respond to the above procedure can usually be removed by...

Page 6: ...INSTALLATION PAGE 1 MRA 60 60 18 35 Complete Unit Consists of 1 MR K30 Riser 1 MRA 30 Basic Unit MRA 32C 32 15 3 8 22 7 8 Complete Unit Consists of 1 MR L30 Leg Kit 1 MRA 30 Basic Unit MRA 32W 32 19 1...

Page 7: ...joints should be tested for leaks with a soap and water solution before operating the unit The test pressure should not exceed 14 W C CAUTION THIS APPLIANCE AND ITS INDIVIDUAL SHUTOFF VALVE MUST BE DI...

Page 8: ...pply connection can be made a Rear Connection can be made by going directly into the pressure regulator female connection 3 8 NPT b Top Connection can be made by 1 Removing knockout hole in top partit...

Page 9: ...INSTRUCTIONS For Legs and Rear Spacers on Counter Models 1 Remove the broiler from the container CAUTION INSURE BURNER SHIPPING SCREWS HAVE NOT BEEN REMOVED 2 Carefully lay the broiler on its back 3...

Page 10: ...wall using 6 sheet metal screws and 6 washers provided Make sure screws hit wall studs Insure wall mount is adequately secured to wall to support weight of broiler 150 Ibs 2 For installation of broile...

Page 11: ...r hanger line up holes and fasten with 3 slotted hex head sheet metal screws provided 4 Fasten bottom of broiler B to wall mount with 2 slotted hex head sheet metal screws provided one each side Screw...

Page 12: ...f the collar plate F NOTE On units where the top of flue collar E is approximately 4 above collar plate F the flue riser extension D is not required 5 Install angles H packaged in riser container with...

Page 13: ...r broiler hanger line up holes and fasten with 3 slotted hex head sheet metal screws provided 4 Fasten bottom of broiler B to riser with 2 slotted hex head sheet metal screws provided one each side Sc...

Page 14: ...in oven Slide flue riser extension C through hole in rear rest D over collar protruding through burner box bottom E 4 Install angles F packaged in riser container with slotted hex head sheet metal scr...

Page 15: ...roiler hanger line up holes and fasten with 3 slotted hex head sheet metal screws provided 4 Fasten bottom of broiler B to riser with 2 slotted hex head sheet metal screws provided one each side Screw...

Page 16: ...e instructions on Page 3 Section 1 2 Lift broiler A with broiler hook B installed Place hook over broiler hanger line up holes and fasten with 3 slotted hex head sheet metal screws 3 Fasten bottom of...

Page 17: ...g should not flutter or POP but should burn with a dull red and a blue haze AIR ADJUSTMENT The infra red burner requires no field air adjustment However if a major change in burner operation is noted...

Page 18: ...ay be times when it will be easier to perform service with the broiler section removed from the riser or wall This may be accomplished by 1 Shut off gas supply to broiler 2 Disconnect gas supply line...

Page 19: ...of broiler Burner fluttering Adjust valve on low setting Burner popping Cracked or loose ceramic Too much heat Incorrect orifices Defective or incorrectly set pressure regulator Slow burner ignition C...

Page 20: ...has a rack which must be moved manually no handle also has a tubular steel venturi C Unit is a counter model W Unit is a wall mount model COMPACT BROILERS PARTS LIST MR 32 MR 36 MR 60 MR 32C MR 32W M...

Page 21: ...R TOP AIR SHIELD 3 3 3 3 3 3 3 3 3 3 1077510 MAIN TOP STIFFNERS 6 6 6 6 6 6 6 6 6 6 1079399 TWIN PILOT VALVE 1 1 1 1 1 1 1 1 1 1 1077911 PILOT SUPPLY TUBE FRONT 1 1 1 1 1 1 1 1 1 1 1077910 PILOT SUPPL...

Page 22: ...5 2 2 2 2 2 1160495 INNER RACK FRAME 1 1 1 1 1 1160494 RACK FACE 1 1 1 1 1 P1438 RACK HANDLE 1 1 1 1 1 1160500 BACK DRIP SHIELD 1 1 1 1 1 1160504 SIDE DRIP SHIELD ASM RT 1 1 1 1 1 1160505 SIDE DRIP SH...

Page 23: ...COMPACT INFRA RED BROILER SECTION FOUR PARTS PAGE 4 Litho in U S A Rev 7 91...

Page 24: ...ixer kettles Cook hold convection ovens Special custom equipment Floor model broilers Bake roast ovens Convection steamers Under fired broilers Pizza ovens Steam kettles Salamander broilers Ranges Til...

Page 25: ...rofessional service may be necessary to extend the useful life of this unit When service is needed contact a Southbend Authorized Service Agency or your dealer To avoid confusion always refer to the m...