INSTALLATION & SERVICE CONNECTIONS
SECTION 1: MODELS: GC-2 & GC-3
INSTALLATION INSTRUCTIONS
Cooker location should have an exhaust system provided directly above the appliance to exhaust
combustion gases generated by the Gas Boiler.
APPLIANCE IS INTENDED FOR USE ON NONCOMBUSTIBLE FLOORS. MINIMUM CLEARANCE FROM COMBUSTIBLE
CONSTRUCTION, 3" ON SIDES AND
2"
FROM BACK.
Ascertain that adequate clearance of left side of appliance is available for servicing components
contained in Cooker Control Enclosure.
Set Cooker in place and "level appliance using spirit level. Mark hole locations on floor through anchoring
holes provided in flanged adjustable feet.
Remove appliance and drill holes into locations marked on floor and insert proper anchoring devices. Set
Cooker back in proper position.
Re-level the appliance, leveling the unit left to right and front to back. Appliance should be elevated on
the right 1/16" to 1/8" to assure proper compartment drainage.
Bolt and anchor appliance securely to the floor. Seal bolts and flanged feet with Silastic or equivalent
compound.
SERVICE CONNECTIONS
Make service connections as indicated in LEGEND (Fig. 1).
GAS INSTALLATION TO CONFORM TO LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES TO NATIONAL FUEL
GAS CODE - ANSI Z2
23.1 -
1980. FURTHER NOTE THAT:
1. THE APPLIANCE AND ITS INDIVIDUAL- SHUTOFF VALVE MUST BE DISCONNECTED FROM THE GAS SUPPLY
PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSURES IN EXCESS OF 1/2 PSIG
(3.45kPa).
2.
THE APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY PIPING SYSTEM BY CLOSING ITS INDIVIDUAL
MANUAL SHUTOFF VALVE DURING ANY PRESSURE TESTING OF THE GAS SUPPLY PIPING SYSTEM AT TEST
PRESSURES EQUAL TO OR LESS THAT 1/2 PSIG (3.45kPa).
ELECTRICAL GROUNDING MUST BE PROVIDED IN ACCORDANCE WITH LOCAL CODES, OR IN THE ABSENCE OF
LOCAL CODES, WITH THE NATIONAL ELECTRIC CODE, ANS1/NFPA 70 - 1981.
3
Summary of Contents for CQ-325S
Page 10: ...PERIODIC MAINTENANCE SECTION 4 MODELS GC 2 GC 3 FIG 2 SIDE VIEW 8 ...
Page 14: ...PERIODIC MAINTENANCE SECTION 4 MODELS 6C 2 GC 3 FIG 3 12 EXHAUST TO DRAIN STEAM IN ...
Page 25: ...PARTS LIST SECTION 7 COMPARTMENT DOOR ASSEMBLY FIG 4 23 ...
Page 28: ...PARTS LIST SECTION 7 COOKER ASSEMBLY FIG 5 25 ...
Page 30: ...PARTS LIST SECTION 7 COOKER CONTROLS FIG 6 27 ...
Page 32: ...PARTS LIST MODELS GC 2 GC 3 SECTION 7 CABINET FIG 7 29 ...
Page 34: ...PARTS LIST SECTION 7 MODELS GC 2 GC 3 GENERATOR CONTROL BOX ASSEMBLY FIG 8 31 OVERRIDE ...
Page 36: ...PARTS LIST SECTION 7 MODELS GC 2 GC 3 GDA 2 GHD 2 GENERATOR ASSEMBLY FIG 9 33 ...
Page 40: ...WIRING DIAGRAM 37 SECTION 8 MODELS GC 2 GC 3 ...
Page 41: ...WIRING DIAGRAM SECTION 8 MODEL GDA 2 38 ...
Page 42: ...WIRING DIAGRAM 39 SECTION 8 MODEL GHD 2 ...
Page 43: ...WIRING DIAGRAM MODELS EDA 2 SCDA 2 GDA 2 DDA 2 SECTION 9 SUPPLEMENT ...