BeerBlast™ 7/14KPH & N
2
-GEN
™ 7/14KPH O&M
South-Tek Systems
25
5
SYSTEM USAGE
5.1
INSTRUCTIONS
The
BeerBlast™ 7/14KPH / N
2
-
GEN™ 7/14KPH is intended to be used to generate Nitrogen, and provide a CO
2
/N
2
blend to push beer out of the keg. Follow the installation instructions above and only use in an approved
environment. The generator generates enough nitrogen to push 14 kegs per hour. Make sure that proper
regulators, cooler temperature, and line temperatures are maintained, otherwise you will not be able to effectively
push beer from the keg. Please consult with your local provider for questions not answered in this manual.
The system is design for 24 hour operation, but routine maintenance on the filters must be performed. See section
“System Maintenance” for detail maintenance instructions.
5.2
ALARM NOTIFICATION
Filter Alarm:
All
BeerBlast™ 7/14KPH / N
2
-
GEN™ 7/14KPH comes standard with a “Filter Alarm” notification. The controller
will display a “Flt Alm” message in red when the filter change is overdue. It is recommended that the filters be
changed once every year or every 1000 hours, whichever comes first. See sect
ion “System Maintenance” for
detail maintenance instructions.
BlastOff™ - Leak Detection System Alarm
An optional feature that can be included with
the system is the BlastOff™ - Leak Detection System. It is a
patented system when installed into the
BeerBlast™ 7/14KPH / N
2-
GEN™ 7/14KPH detects line leaks within the
downstream gas lines from the N
2
Generator to the kegs. Line leaks could be due to a keg not being tapped
correctly, a beer gas line leak or fitting therein failing, etc. These leaks are potential safety hazards, they can
cause the CO
2
to deplete quickly, and could cause your
BeerBlast™ 7/14KPH / N
2
-
GEN™ 7/14KPH to run in
excess (decreasing the life of the unit).
Once a leak has been detected, the BlastOff
™ set to initiate a buzzer, displays “B.Off” in red on the controller
screen, and shuts off the
BeerBlast™ 7/14KPH / N
2
-
GEN™ 7/14KPH until the problem has been remedied. To
reset the BlastOff
™, simply turn off the BeerBlast™ 7/14KPH / N
2
-
GEN™ 7/14KPH and turn it back on. The
BeerBlast™ 7/14KPH / N
2
-
GEN™ 7/14KPH can be ordered with the BlastOff™ System Factory installed or the
system can be retrofitted in the field. Some rewiring is required to field install.
Never reset repeatedly;
if the BlastOff™ goes off daily, there is a real potential issue. Consult your installer for a
solution. The label below and the Logo above will be on your BeerBlast™ 7/14 KPH or N
2
-
GEN™ 7/14 KPH if
factory installed.
Summary of Contents for BEERBLAST 14KPH
Page 3: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 3 Notes Page ...
Page 5: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 5 Notes ...
Page 16: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 16 ...
Page 17: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 17 ...
Page 19: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 19 Figure 1 100 N2 Storage Tank Setup ...
Page 31: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 31 Last Page ...