6. Press the
Start
button.
The
LOW CURRENT
message will
turn up:
7. Turning the
Test current control
clockwise, increase current until
obtaining the desired value or until
the current bargraph reads 100
divisions. The bargraph will show
the test current value as the
percentage of the nominal value
selected by using the
Range
selector
.
8. The equipment should be connected to the mains supply in order to
work with 100 A.
9. The lowest current for measuring is 10% of the range nominal value. It
is important to consider that the measurement errors increase while
test current decreases. The error is specified for test currents higher
than 80%.
10. The
Display
will show the resistance value measured and the unit
used (Ω [ohms], mΩ [milli-ohms] or µΩ [micro-ohms]).
11. The value can be retained in the
second line of the display by
pressing the button
Hold
. If you
press this button again, the value
will be erased.
13