![Soundstream Tarantula ARS.2 Installation Manual Download Page 10](http://html1.mh-extra.com/html/soundstream/tarantula-ars-2/tarantula-ars-2_installation-manual_1335672010.webp)
SYSTEM PROGRAMMING -
Menu 1
PAGE 10
INSTALL MANUAL
SYSTEM WIRING DETAILS
SYSTEM GROUND INPUT
JUMPER SELECTABLE PARK LIGHT OUTPUT (+ OR -)
(+) SIREN/ HORN OUTPUT (+)
STARTER-KILL/ ANTI-GRIND OUTPUT
PINK
OUTPUT TO ACTIVATE IGNITION CIRCUIT
PINK/WHITE
SELECTABLE OUTPUT (DEFAULT SECOND IGNITION)
RED
30A HIGH CURRENT 12VOLT INPUT
PURPLE
OUTPUT TO ACTIVATE START CIRCUIT
RED
30A HIGH CURRENT 12VOLT INPUT
ORANGE
OUTPUT TO ACTIVATE ACCESSORY/ HEATER CIRCUIT
BLUE
NEGATIVE OUTPUT FOR UNLOCK
12+ OUTPUT FOR DOOR LOCK MODULE
GREEN
NEGATIVE OUTPUT FOR UNLOCK
3-PIN KEYLESS ENTRY CONNECTOR
ARS.1
WHITE
BLACK
ORANGE/BLACK
BROWN
SYSTEM PROGRAMMING -
Menu 1
PAGE 11
INSTALL MANUAL
SYSTEM WIRING DETAILS
PIN-1 PURPLE Starter Output-
This wire will test 0V when the key is off, in the Accessory position and
when the Ignition is in the on position. The starter wire is 12volts during the start/ crank position only.
PIN-2 ORANGE Heater/Acc Output-
This wire will test 0V when key is off, 12volts in the ACC and IGN
positions and off during start/ crank position.
PIN-3 RED 12volt Input(30amp)-
This input supplies the 12volt power for the Ignition, Park Lights
and the Selectable output.
PIN-4 RED 12volt Input(30amp)-
This input supplies the 12volt power for the Accessory and Starter
outputs.
PIN-5 PINK/WHITE Selectable Output -
2nd Ignition, Accessory or Start output. Programmable.
Note: This output does not switch to default when the system is reset.
PIN-6 PINK Ignition Output-
This wire will test 0V in the off and Accessory positions the switch
to12volts in the Ignition and Start positions.
PIN-1 BROWN (+) Siren Output-
Connect to the positive input to the alarm siren. This output is
programmable for horn activation. A relay is required to convert the polarity to a negative output.
PIN-2 ORANGE/BLACK Starter Kill/ Anti-Grind-
This wire can be connected to an additional relay to
disable the start circuit when the lock button is pressed. The output will also stay on when remote started, this
will prevent the starter motor from being re-engaged while the vehicle is running.
PIN-3 WHITE Jumper Selectable Park Light Output (+ or -)-
Connect to the vehicles positive
park light wire or change the jumper and connect to the vehicle negative park light wire. The default position of
the jumper is
Positive Park light Output.
PIN-4 BLACK
System Ground Input-
Connect to chassis ground.
PIN 1- GREEN- Negative Lock Output
Connect to lock wire from the switch on vehicles with a negative type switch. **LOW CURRENT ONLY**
PIN 2- 12volt Output for Door Lock Module
This output will supply 12volts for a plug-in type door lock module. Do not use this input to power-up relays
**LOW CURRENT ONLY**
PIN 3- BLUE- Negative Unlock Output
Connect to lock wire from the switch on vehicles with a negative type switch. **LOW CURRENT ONLY**
ARS.1
4-PIN CONNECTOR