background image

 

Test 

Sound:x 

UP/DOWN to choose Y off sound active model 1-9, 

press ENTER to save 

Test 

Tilt:xxx 

UP/DOWN to adjust Y value address, press ENTER 

to save.(only active with 

Auto:x and Sound:x

MENU5: 

PassWord 

Press   

ENTER

 

 

 

PassWord 

UnLock 

Password---unloack.  set  up  three-digit-number 

password. 

ENTER→UP/DOWN 

to 

choose 

digit(0-

9)→ENTER. Default password is 988. Power 

off fixture to active password unlock function 

 

PassWord 

Lock 

Passwork-lock.  Password---unloack.    set  up 

three-digit-

number  password.  ENTER→UP/DOWN 

to  choose  digit(0-

9)→ENTER.  Default password  is 

988.  Power  off  fixture  to  active  password  lock 

function. 

MENU6: 

Re- Def- 

ENTER TO RESET factory defaults 

MENU7: 

Reset   

ENTER to RESET 

 

Comment:    Press MENU to back to the last option. Press ENTER to save. 

How  to  erase  password:  Please  press  MENU→UP/  DOWN→MENU  SYS-SET→ENTER→UP/ 

DOWN→SYS-SET 

Password→ENTER→UP/ 

DOWN→NO→ENTER→password(default 

988)→ENTER 

 

 

DMX Protocol 

(12CH

 

CH 

Function 

Description 

CH1 

0-255 

CH2 

Y 16 bit 

0-255 

CH3 

Dimmer   

0-255 from dark to bright 

CH4 

0-255 from dark to bright 

CH5 

0-255 from dark to bright 

CH6 

0-255 from dark to bright 

CH7 

0-255 from dark to bright 

 

Cable Connectors 

Cables  must  have  a  male  XLR  connector  on  one  end  and  a  female  XLR  connector  on  the 

other end. 

A word on termination: DMX is a resilient communication protocol, 

however errors still occasionally occur. Termination reduces signal errors, and therefore best 

practices  include  use  of  a  terninator  in  all  circumstances.  If  you  are  experiencing  problems 

with  erratic  fixture  behavior,  especially  over  long  signal  cable  runs,  a  terminator  may  help 

improve performance. 

To  build  your  own  DMX  Terminator:  Obtain  a  120-ohm,  1/4-watt 

resistor, and wire it between pins 2&3 of the last fixture. They are also readily available from 

specialty retailers

.

 

 

 

 

 

 

 

 

 

 

 

 

 

Complimentary signal cable can transmits signals to 20 unit fixtures 

at most. Signal amplifier is a must to connect more fixtures 

Summary of Contents for BEAM-ARC5-10W

Page 1: ...BEAM ARC5 10W USER MANUAL PRO LIGHTING ...

Page 2: ...this item and if you want to collaborate we are looking for a feedback from you about the operation of the product and for possible improvements to introduce in the next future Go to our website www soundsationmusic com and send an e mail with your opinion this will help us to build instruments ever closer to customer s real requirements One last thing read this manual before using the instrument ...

Page 3: ...ace the product in wet or dirty environments Do not remove the protective coverings Do not cover any of the productss ventilation holes Air must circulate freely around the product Do not set the product on a surface with excessive vibration Do not expose the product to high electro magnetic interference Do not expose the product to heat cold wet in improper way in respect to its IP grade Do not l...

Page 4: ...pact on the environment and human health due to potentially hazardous substances that are generally associated with EEE At the same time your cooperation in the correct disposal of this product will contribute to the effective usage of natural resources For more information about where you can drop off your waste equipment for recycling please contact your local city office waste authority approve...

Page 5: ...riginal proof of purchase To avoid any damages in transit please use the original packaging if available Alternatively you can send the product to SOUNDSATION SERVICE CENTER Via Enzo Ferrari 10 62017 Porto Recanati Italy In order to send a product to service center you need an RMA number Shipping charges have to be covered by the owner of the product For further information please visit www sounds...

Page 6: ...pare parts components from manufacturer directly To avoid electric shock all fixtures must be connected to circuits with a suitable ground Make sure the power cord is never crimped or damaged Do not power on and power off the fixture in a short time For your safety do not touch fixture when running When use DMX controller please make sure that there is no interference sources e g intercom high fre...

Page 7: ...f stand alone 120 126 Y off stand alone CH9 Stand alone sound active 127 133 Y sound active 134 140 Y sound active 141 147 Y sound active 148 154 Y sound active 155 161 Y sound active 162 168 Y sound active 169 175 Y sound active 176 182 Y sound active 183 189 Y sound active CH9 Stand alone sound active 190 196 Y off sound active 197 203 Y off sound active 204 210 Y off sound active 211 217 Y off ...

Page 8: ...and alone 50 56 Y stand alone 57 63 Y stand alone 64 70 Y off stand alone 71 77 Y off stand alone 78 84 Y off stand alone 85 91 Y off stand alone 92 98 Y off stand alone 99 105 Y off stand alone 106 112 Y off stand alone 113 119 Y off stand alone 120 126 Y off stand alone 127 133 Y sound active 134 140 Y sound active 141 147 Y sound active 148 154 Y sound active 155 161 Y sound active 162 168 Y so...

Page 9: ...TER password default 988 ENTER DMX Protocol 12CH CH Function Description CH1 Y 0 255 CH2 Y 16 bit 0 255 CH3 Dimmer 0 255 from dark to bright CH4 R 0 255 from dark to bright CH5 G 0 255 from dark to bright CH6 B 0 255 from dark to bright CH7 W 0 255 from dark to bright Cable Connectors Cables must have a male XLR connector on one end and a female XLR connector on the other end A word on termination...

Page 10: ...r cables Primary fuse blown Replace fuse Secondary fuse blown Replace fuse Fixture resets but does not respond correctly to controller DMX mode operation Controller not connected Connect controller Incorrect addressing of the fixtures Check address setting on fixture and controller Bad data link connection Inspect cables and correct poor connections and or broken cables Conflict between tracking a...

Reviews: