background image

INTERSECTOR LED LIGHT

 #ENT3(y)3(x) - SURFACE MOUNT
#PNT3DGBB DECK/ GRILLE BRACKET, BLACK

ADVANCE PATTERN

Flash pattern can only be changed when the LED module is in a flashing mode (disabled in cruise or steady ON functions).  When the light is flashing, momentarily touch the white wire to ground for >250ms and <1s 

(light will go steady high) then release.  The flash pattern will advance to the next pattern.  If the light module was at the last pattern, the pattern will reset to the 1st pattern.  

BACKUP PATTERN

This function is only valid when the LED module is in a flashing mode (disabled in cruise or steady ON functions).  When the light is flashing, momentarily touch the white wire to ground for >1s and < 2s (light will go 

steady high, steady low) then release.  The flash pattern will backup to the previous pattern.  If the light module was at the first pattern, the pattern will change to the last pattern on the list. 

COLOR SWAP

This function is only valid for dual color light modules and can only be changed when the light module is in a flashing mode (disabled for single color modules and when light module is operating in cruise or steady ON 

functions).  When the light is flashing, momentarily touch the white wire to ground for >2s and <3s (light will go steady high, steady low, off) then release.  The light module will switch between Color Swap OFF and 

Color Swap ON.  When Color Swap is OFF, the 1st color will flash 1st on a dual color pattern.  When Color Swap is ON, the 2nd color will flash 1st on a dual color pattern.

SIMULTANEOUS/ALTERNATE

This function can only be changed when the LED module is in a flashing mode (disabled in cruise or steady ON functions) and only has an effect when at least 2 LED modules have the green sync wire connected 

together.  When the light is flashing, momentarily touch the white wire to ground for >3s and <4s (light will go steady high, steady low, off, steady high) then release.  The light module will switch between Simulta-

neous and Alternate each time this sequence is done.  To have light modules flash simultaneously, both light modules need to be set to the same sequence type (Set-Up Table).  To have light modules flash alternately, 

the light modules need to be set to different sequence types (Set-Up Table).

PATTERN RESET

This function is only valid when the LED module is in a flashing mode (disabled in cruise or steady ON functions).  When the light is flashing, momentarily touch the white wire to ground for >5s and <6s (light will go 

steady high, steady low, off, steady high, steady low, off) then release.  The flash pattern will reset to the 1st pattern in the list.

FACTORY RESET

This function is only valid when the LED module is in a flashing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily touch the white wire to ground for >6S and <7S (light will go 

steady high, steady low, off, steady high, steady low, off, steady high) then release.  The LED module will reset to: pattern=1, Function Table=1, Color Swap=OFF, Simultaneous.

SETUP TABLE

SECONDS

USER INTERFACE

FROM

TO

VISUAL FEEDBACK

ACTION TAKEN

0

1

STEADY-HIGH (60%)

FORWARD ONE PATTERN

1

2

STEADY-LOW (30%)

BACKWARD ONE PATTERN

2

3

OFF

COLOR SWAP (OFF OR ON )

3

4

STEADY - HIGH (60%)

SEQUENCE TYPE:

SIMULTANEOUS OR ALTERNATE

4

5

STEADY - LOW (30%)

SET FUNCTION TABLE

5

6

OFF

RESET TO PATTERN 1

6

7

STEADY-HIGH (60%)

FACTORY RESET (PATTERN 1, COLOR SWAP: 

OFF, SIMULTANEOUS)

SEPARATE COLOR CONTROL: OFF

If held longer than 7 seconds, the light will go back to flashing the current

pattern and no action will be taken.

Summary of Contents for Intersector ENT3 3 Series

Page 1: ...ersector light to any power source directly WILL permanently damage the light and will void warranty IMPORTANT FOR PROPER OPERATION ALL WIRES MUST BE CONNECTED FROM FLASHER TO LIGHT HEAD GREEN BLACK R...

Page 2: ...HITE to Ground to change ID i Identify ID by number of sequential flashes ii Possible ID s 2 or 4 e Disconnect Power to exit ID mode 2 Set Pattern Must be done individually to each light prior to sync...

Page 3: ...a template to mark locations of mounting screws 6 Size pilot holes for mounting screws appropiately 7 Fasten light using bezel and mounting screws Do not torque mounting screws beyond 20 in lbs SURFAC...

Page 4: ...ions and only has an effect when at least 2 LED modules have the green sync wire connected together When the light is flashing momentarily touch the white wire to ground for 3s and 4s light will go st...

Page 5: ...ION TABLES Changing the function table is only enabled when the LED module is in a flashing mode disabled in cruise or steady ON functions The functional operation of the LED module can be changed whi...

Page 6: ...2 TITLE 13 QUAD 11 QUAD 2 12 DOUBLE 2 13 RANDOM 1 14 RANDOM 2 SYNC 2 Syncronizing the flashing of multiple light modules is accomplished by connecting the Green wires of different light modules togeth...

Page 7: ...Output 70 30 80 40 90 50 Intersector LED Light Remote Mode Functionality Red Wire Red Wht Wire Single Color Dual Color Color Swap OFF Color Swap ON Color Swap OFF Color Swap ON Cruise Cruise Color 1 C...

Page 8: ...Voltage 10 16 Vdc CURRENT CONSUMPTION PER MODULE 10 16 Vdc 9 LED Single Color 18 LED Dual Color 1 25A 12 8 Vdc AFTER POWER IS ON touching the WHITE wire to the ground will allow you to change various...