background image

Page 8

For Technical Support - Please Call 1-800-338-7337

or visit

www.soundoffsignal.com

500 Series Control System and Siren Amplifier

ENGSA5(xxxSx)

Rev. D - 07/2021

R

EPLACEMENT

P

ARTS

& A

CCESSORIES

Part #

Description

PSRN5CTRL1

500 Series Remote Control Panel - Push Button Siren Controls

PSRN5CTRL2

500 Series Remote Control Panel - Rotary Knob Siren Controls

PSRN5CTRL3

500 Series Console Control Panel - Push Button Siren Controls

PSRN5CTRL4

500 Series Console Control Panel - Rotary Knob Siren Controls

PSRN5LEG1

Replacement Button Legend Sheet for Console and Remote Panels

PSRNHHC2

Replacement Handheld Control Panel

PSRN5ANR1

Replacement Amplifier - 100w

PSRN5ANR2

Replacement Amplifier - 200w

PSRN5MC01

500 Series Microphone

PSRN5HDK1

Replacement Input, Output, & Power Harness Kit

PSRN5HDK3

Hardware Conversion Kit - Microphone to 500 Siren Direct Connect with
25 audio extension cable.

PSRN5HDK4

Hardware Conversion Kit - Microphone to 500 Siren Direct Connect
without extension cable.

PSRN5MMC1

Hardware Kit - Microphone Mounting Kit

PSRN5BLBK1

Hardware Kit - Bail Bracket

A

FTERMARKET

S

YSTEM

H

ARNESS

O

PTIONS

*

Part #

Description

91

1

C

ir

cu

it

s

911.500.10

10 Foot Harness Kit - Includes all labeled circuits for
connectors CN2, CN4, CN5, CN6, CN7, CN9, and CN12, at
10 feet long, and CN8 at 25 feet long.

Order directly from 911 Circuits - (503) 393-3444

911.500.25

25 Foot Harness Kit - Includes all labeled circuits for
connectors CN2, CN4, CN5, CN6, CN7, CN8, CN9, and
CN12, at 25 feet long.

Order directly from 911 Circuits - (503) 393-3444

P

at

ro

l

P

ow

er

SOSBP500-10

10 Foot Harness Kit - Includes all labeled circuits for
connectors CN2, CN4, CN5, CN6, CN7, CN9, and CN12, at
10 feet long, and CN8 at 25 feet long.

Order directly from Patrol Power - (833) 701-1930

SOSBP500-25

25 Foot Harness Kit - Includes all labeled circuits for
connectors CN2, CN4, CN5, CN6, CN7, CN8, CN9, and
CN12, at 25 feet long.

Order directly from Patrol Power - (833) 701-1930

H

ARNESS

A

SSEMBLY

P

ART

N

UMBERS

(B

UILD YOUR OWN

)

Part

Description

Connector

CN1

Crimp Ferrule Connection (over bare wire)
Ferrule Crimp Tool: American Electrical SQ28-10 (or equivalent)
Installation/Extraction Tool: 1/8” Allex Hex Key

Connector

CN2

Connector Housing: Hirose DF22R-3S-7.92C(28)
Pins: Hirose DF22A-1012SCF

(Tin Terminals - Jxxxxx and lower)

Pins: Hirose DF22A-1012SCFA (Gold Terminals - Jxxxxx and higher)

Pin Crimp Tool (Recommended): Hirose HT103/DF22A-1012
Pin Crimp Tool (Optional): Match MOBCT1424 (or equivalent)
Extraction Tool: Flat Blade Screwdriver - 1.4mm Wide
Application Specification:

https://bit.ly/3a54fEy

Connectors

CN4, CN5, CN6

Connector Housing: Molex 3901-2080
Pins: Molex 45750-3111 (Fits 5A or 10A Outputs, 16 AWG)
Pin Crimp Tool: Molex 200218-2200
Extraction Tool: Molex 1103-0044
Application Specification:

https://bit.ly/3cifegs

Connector

CN7

Connector Housing: Molex 3901-2100
Pins: 3900-0039 (Bag) (Low Current Connections, 18-24 AWG)
Optional Pins: 3900-0038 (Reel) (Low Current Connections, 18-24 AWG)
Pin Crimp Tool: Molex 63819-0901
Extraction Tool: Molex 1103-0044
Application Specification:

https://bit.ly/3t5cIQC

Connector

CN8

Connector Housing: Molex 3901-2040
Pins: 3900-0039 (Bag) (Low Current Connections, 18-24 AWG)
Optional Pins: 3900-0038 (Reel) (Low Current Connections, 18-24 AWG)
Pin Crimp Tool: Molex 63819-0901
Extraction Tool: Molex 1103-0044
Application Specification:

https://bit.ly/3t5cIQC

Connector

CN9

Connector Housing: Molex 3901-2060
Pins: 3900-0039 (Bag) (Low Current Connections, 18-24 AWG)
Optional Pins: 3900-0038 (Reel) (Low Current Connections, 18-24 AWG)
Pin Crimp Tool: Molex 63819-0901
Extraction Tool: Molex 1103-0044
Application Specification:

https://bit.ly/3t5cIQC

Connector

CN12

Connector Housing: Molex 171692-0102
Pins: 76823-0322 (12 AWG)
Pin Crimp Tool: Molex 63825-7100
Extraction Tool: Molex 63824-0810
Application Specification:

https://bit.ly/3t3W2cw

T

ECHNICAL

S

PECIFICATIONS

General Information

Amplifier Dimensions

2.63" H x 7" W x 7" D

Full Size Control Panel

3.6" H x 7.2" W x 2.1" D

Handheld Control Panel

5" H x 2.5" W x 1" D

Input Voltage

10-16Vdc (Negative Ground)

Boxed Weight

10 lbs.

Operating Temperature

-40°C to +65°C

Diagnostic LEDs

Control Panel Diagnostic LEDs (3),

Siren Amplifier LEDs (2)

Refer to Reference Table

Siren

Input Current

11 Amps @ 13.4 VDC - 100W System
22 Amps @ 13.4 VDC - 200W System

Standby Current

Ignition ON - 500mA

Ignition OFF - <4mA

Output Power

1x100W RMS Max (11 Ohm Speaker)
2x100W RMS Max (11 Ohm Speaker)

Siren Frequency

675Hz - 1633Hz

Over Voltage Protection

Yes

Low Voltage Shutdown

Programmable

California Title 13 Compliance

Programmable

Hands Free Operation

Programmable

Speaker Protection

Short & Open

Light Control

Solid State Outputs

6 @ 10A

9 @ 5A

Slide Switch Relays

3 @ 20A

Not to exceed 50A total

Dry Contact Relays

2 @ 10A

Horn Ring Relay

1 @ 5A

Diode Isolated Outputs

3

Inrush Capable Outputs

6

Arrow Control

Programmable

Control Panel Slide Switch Positions

Off, 1, 2, 3 - Programmable

Control Panel Auxiliary Buttons

1-8, Programmable

Control Panel Siren Buttons

Standby, Wail, Yelp, Tone, Radio Rebroadcast, Manual,

Air Horn - All Programmable

Maximum Switch Current

75A (Excludes Horn Ring)

(Includes Relays and Solid State Switches)

T

ECH

S

PECS

& R

EPLACEMENT

P

ARTS

† This list is not intended to be fully inclusive or complete.

Summary of Contents for Blueprint 500 Series

Page 1: ...perly fused at power source Install protective grommets when routing wire through firewall or metal TABLE OF CONTENTS Introduction 2 Siren System Notice 2 Caution Notice to the Installer 2 Instruction...

Page 2: ...rator should routinely verify that the siren system is securely fastened to the vehicle and properly functioning Effective sirens generate loud sound pressure levels that can potentially cause hearing...

Page 3: ...ipment into the aftermarket console For best results use equipment specific brackets or faceplates POWER FUSING Main Power Fusing WARNING TO AVOID DAMAGE OR INJURY DO NOT CONNECT POWER WHEN CIRCUIT IS...

Page 4: ...ring shutdown of the circuit This is shown on page 14 This diode should be rated at a minimum of 100v at 1a CN4 CN5 CN6 Solid State Programmable Outputs Connectors CN4 CN5 and CN6 have five solid stat...

Page 5: ...witches are not the same thing as a parallel splitter and will cause data transmission problems CN11 RJ 45 Control Panel Databus Connectivity See the data bus connectivity schematic on page 12 CONTROL...

Page 6: ...re placing the vehicle into service Volume can be set through the SoundOff Central bluePRINT Software PA Microphone The PA Microphone in bluePRINT is a specialized high gain microphone that connects v...

Page 7: ...w 1 Red 2 Greens Output Board Voltage High 2 Reds 1 Green Comm Fault USB Port 2 Reds 2 Greens Comm Fault CAN Port 3 Reds 2 Greens Comm Fault Console Control Panel Port 2 Reds 4 Greens Comm Fault Outpu...

Page 8: ...Specification https bit ly 3a54fEy Connectors CN4 CN5 CN6 Connector Housing Molex 3901 2080 Pins Molex 45750 3111 Fits 5A or 10A Outputs 16 AWG Pin Crimp Tool Molex 200218 2200 Extraction Tool Molex 1...

Page 9: ...ls 1 Blue Relay Slide 1 20A 2 Green Relay Slide 2 20A 3 Yellow Relay Slide 3 20A 1 Green Black Relay 3 Ext Horn Ring Output 5A 2 Green White Relay 3 Ext Horn Ring Input 5A 3 Green Lightbar Bus Channel...

Page 10: ...Blue Red CAN A 3 Blue Radio Rebroadcast External PA Input 1 4 Light Blue Black CAN Shield 5 Light Blue White CAN A 6 Blue Radio Rebroadcast External PA Input 2 1 Orange Speaker A Out 2 Orange Black S...

Page 11: ...points as shown below Input Nodes are only necessary when using additional discrete inputs beyond the eight provided inputs from the 500 Series Control System A lightbar breakout box can be configured...

Page 12: ...07 2021 LIGHTBAR DATA PORT BUS EXAMPLES Lightbar Data Bus 1 Lightbar Data Bus 2 Lightbar Data Bus 1 Optional RJ 45 to Three Wire Control Adapter LIGHTBAR LIGHTBAR LIGHTBAR LIGHTBAR Breakout Box Break...

Page 13: ...S 2 CONSOLE DATA BUS EXAMPLES CONTROL PANEL BUS 2 EXAMPLE CONTROL PANEL PA Mic Console or Remote Control Panel with PA Connection at Control Panel Inside View CONTROL PANEL PA Mic Mic Jack Kit PSRN5HD...

Page 14: ...s energy from when it is switched on This energy store is often referred to as reactive power When the inductive load is shut down this reactive power is converted into stray voltage Per the laws of e...

Reviews: