P
IN
1
* B
UILDING AN
RJ-45
TO THREE
WIRE CONTROL ADAPTER
Using a standard RJ-45 Connector
and a short length of CAT-5 cable,
insert the blue pair of wires into
pins #4 and #5 and then crimp
the plug. This is very similar to
building an Ethernet cable but only
the blue pair is necessary.
Connect both of those wires to the
lightbar data wire.
T
OP
S
ID
E
-
R
EL
EA
SE
ON
B
OT
TO
M
P
IN
8
Page 12
For Technical Support - Please Call 1-800-338-7337
or visit
www.soundoffsignal.com
500 Series Control System and Siren Amplifier
ENGSA5(xxxSx)
Rev. D - 07/2021
L
IGHTBAR
D
ATA
P
ORT
B
US
E
XAMPLES
Lightbar Data Bus 1
Lightbar Data Bus 2
Lightbar Data Bus 1
Optional RJ-45 to Three Wire Control Adapter*
L
IGHTBAR
L
IGHTBAR
L
IGHTBAR
L
IGHTBAR
Breakout
Box
Breakout
Box
L
IGHTBAR
Lightbar Data Bus 1
Lightbar Data Bus 2
Parallel
Splitter
Internal Lightbar Control Example
External Lightbar Control Example
CP Data Bus
Parallel
Splitter
C
ONTROL
P
ANEL
**
**Any remote bluePRINT Control
Panel cam be installed, including
remote push button, rotary, or
handheld.
BLUE
PRINT L
INK
BLUE
PRINT S
YNC
PA Mic
C
ONTROL
P
ANEL
B
US
#1 (R
EMOTE
) D
ATA
B
US
E
XAMPLES
C
ONTROL
P
ANEL
B
US
#1 E
XAMPLE
To Lightbar Data Wire
†
†
When using a lightbar B.O.B. as an input
node, it gets connected here. There are no
other special requirements.