Diagnostic Status LED Lights (Rear of Amplifier)
There are two different LED lights on the rear of the amplifier. Each
LED light represents a different portion of the siren function.
The upper light is marked “OUTPUT STATUS.” The lower light is
marked “INPUT STATUS.” Please see the below tables showing what
the codes mean.
The error code sequence start and finish is indicated by a long orange
pulse. In the case there is more than one code, a short orange pulse
is shown between codes.
Output Status Diagnostic Codes
Input Status Diagnostic Codes
Sequence
OUTPUT STATUS Condition
Steady Green
No Faults
Flashing Red
Running in Boot loader Mode
1 Red, 1 Green
Output Board Voltage Low
1 Red, 2 Greens
Output Board Voltage High
2 Reds, 1 Green
Comm Fault - Lightbar 1
2 Reds, 2 Greens
Comm Fault - Lightbar 2
2 Reds, 3 Greens
Comm Fault - Lightbar 3
2 Reds, 4 Greens
Comm Fault - Controller Board
3 Reds, 1 Green
Output Fault - Outputs 1-15
3 Reds, 2 Greens
Output Fault - S1 - S3 Relays
3 Reds, 3 Greens
Output Fault - R1 - R2 Relays
3 Reds, 4 Greens
Output Fault - Horn Ring Relay
7 Reds, (x) Greens
Special Code, Contact Tech Support
Sequence
INPUT STATUS Condition
Steady Green
No Faults
Flashing Red
Running in Boot loader Mode
1 Red, 1 Green
Output Board Voltage Low
1 Red, 2 Greens
Output Board Voltage High
2 Reds, 1 Green
Comm Fault - USB Port
2 Reds, 2 Greens
Comm Fault - CAN Port
3 Reds, 2 Greens
Comm Fault - Console Control Panel Port
2 Reds, 4 Greens
Comm Fault - Output Board
2 Reds, 5 Greens
Output Fault - Remote Control Panel Port
3 Reds, 1 Green
Output Fault - LIN Data Bus (CN7.10)
4 Reds
Configuration Fault
5 Reds, 1 Green
Siren Speaker Fault - Siren A
5 Reds, 2 Greens
Siren Speaker Fault - Siren B
6 Reds
Output Fault
7 Reds, (x) Greens
Internal Error Code
D
IAGNOSTIC
F
UNCTIONS AND
N
OTIFICATIONS
Resetting Outputs
Should any of the solid state
outputs shut off due to a fault
condition, the output will need to
be reset. A diagnostic check should
be conducted prior to a reset.
Resetting can be done in three
different ways:
• Through the SoundOff Central
bluePRINT Software
• By pressing the reset button
shown at the top right of the
board
• By connecting the programmed
reset wire to ground typically
with a user supplied momentary switch. This function can be
programmed to any input, using SoundOff Central bluePRINT.
Diagnostic Status LED Lights (Control Panel)
The control panel can also indicate additional system faults, as
detailed in the below table.
S1
S2
Diag
Condition
On
On
Flashing
Over Temperature
Off
On
Flashing
Under Voltage
On
Off
Flashing
Over Voltage
Flashing
Off
Flashing
Comm Fault - Relay
Off
Flashing
Flashing
Comm Fault - Amp
Flashing
Flashing
Flashing
Comm Fault - Relay & Amp
On
Off
Off*
Speaker 1 Active
Off
On
Off*
Speaker 2 Active
On
On
Off*
Speaker 1 & 2 Active
Off
Off
Off*
Speaker 1, 2, or both is not
functioning.
*While the siren mode is active.
Reset Button