RELAY TYPES
The card can be equipped with a variety of different contact relays. Catalog models include the 3002R-EP6 with
6A changeover contacts, and the 3202R-EP16 with 16A heavy duty relays.
Please note that all current data are given for resistive load only. Switching of inductive loads requires application
of a suitable degradation factor - see note below or refer to relay manufacturer's data sheet.
3202R-EP6
6A RELAY
high voltage changeover contact, universal use for all applications
max. switching current:
8A @ 230V resistive load
max. switching voltage:
440V AC @ resistive load
max. switching power:
2000VA AC
contacts:
1x changeover (NC/NO)
3202R-EP16
16A RELAY
high current N.O. contact, for power switching applications
max. switching current:
16A @ 230V resistive load
max. switching voltage:
380V AC @ resistive load
max. switching power:
4000VA AC
contacts:
1x closing contact (N.O.)
NOTE:
When selecting and ordering the appropriate relay card, please note, that all data given by the relay manufacturers
are for RESISTIVE LOAD only. Incandescent lamps may be considered to be resistive loads. Switching inductive
loads, such as transformers or solenoids, requires lower loads - we strongly recommend not to exceed 50% of the
resistive load data. Besides, contacts may burn due to inductive spikes and sparks. Make sure to add protective
circuitry (RC combinations, VDR resistors) if switching inductive loads. Switching inductive loads on the mains
power supply may also generate high frequence noise and degrade the power supply quality. If switching capacitive
loads (electronic ballasts or psu) inrush current limiting devices may be required to prevent contact damage.
TECHNICAL DATA
Dimensions:
70 mm x 70 mm x 45 mm
Power Supply:
12V DC approx. 30mA (no relay) to 150mA (both relays)
DMX IN:
1 Unit Load
DMX OUT:
fed-through
Relay Out:
see relay data (above)
Order Code.:
3202R-EP0 (no relays fitted)
3202R-EP6 (6A universal relays fitted)
3202R-EP16 (16A mini contactors fitted)
NOTE: boards may be ordered and fitted with 24V relays upon request.