COUGH/REVERSE TALKBACK Switch
This user-provided facility has two functions, as follows:
1) The Input Channel is muted when all of the following conditions are met: The
Mic input is selected, the Fader is up and the Cough Switch is closed. This allows
the Presenter/Guest to temporarily mute his or her microphone.
2) The Cough Switch allows the Guest to force a PFL so that he or she may talk
to the Presenter. This forced PFL occurs when all of the following conditions are
met: The Mic input is selected, the Fader is down and the Cough Switch is closed.
Two pins on the Remotes socket are used for this feature, as follows:
Ground Pin
2
Cough Pin
14
A switch may be connected between pins 14 & 2.
Insert Point (Send/Return)
Two pins on the Remotes socket are used for this feature, as follows:
Send
Pin 22
Send 0V
pin 21
Return
Pin 23
Return 0V
pin 18
You will need to remove link 5 from the pcb in order to use the insert Point.
Power Rails
The following power rails are available as follows:
+16V
Pin 20 (supplied via a 10R current-limiting resistor)
-16V
Pin 19 (supplied via a 10R current-limiting resistor)
0V audio
Pins 18 and 21.
Options
Designating a channel as Local or Distant
Link 2 may be set to A for Local or to B for Distant. This will control which set of
speakers is muted when this channel is opened: if A is selected the Control Room
Monitor output will be muted, or if B is selected the Studio Monitor output will be
muted.
Aux - Pre-fade or Post-fade
The factory default for the Auxiliary Output on the Mono Input channel is pre-fade.
This may be altered to post-fade by moving link 3.
Phantom Power for Microphones
If Link 1 is in place then +48V will be present on pins 2 and 3 of the Mic XLR
connector. Phantom powered mics should not be plugged in with the +48V
switched on. You should also be aware that some mics draw an unusually large
current. The current for each mic is limited to 14mA by series resistors.
14
Applications
Summary of Contents for MBI 10 Series
Page 1: ...USER GUIDE SERIES 10...
Page 10: ...6 Introduction to the MBI Series 10...
Page 15: ...10 Block Diagrams...
Page 28: ...Meterbridge Distribution Board SC3357 22 Applications...
Page 29: ...Mono Input Channel Description Operation Specification Mono Input Channel 23...
Page 33: ...Telco Channel Description Operation Specification Telco Channel 27...
Page 36: ...switch is depressed and is properly connected to the Hybrid 30 Telco Channel...
Page 37: ...Stereo Input Channel Description Operation Specification Stereo Input Channel 31...
Page 41: ...Master Section Description Operation Specification Master Section 35...
Page 45: ...Monitor Section Description Operation Monitor Section 39...
Page 51: ...Appendices Glossary Dimensions Warranty Appendices 45...