 without protection elements the unit has to be sent to the producer for repair. 
 

- Overvoltage at the output may damage the power supply. Coming from reliable operation of the 

units have been already made, those are not equipped with any OVP circuit. The OVP protection in 
the case of an active load (DC motor) may be done by two external rapid diodes connected 
according to following figure 4: 

 
In the event of passive inductive resistor load (solenoid), there must be used a rapid diode D1 at 
least. The adjustable thyristor crowbar protection against internally as well as externally caused 
overvoltages may be delivered as an option or may be made by a customer qualified person. In 
generally, it’s difficult to predict max. allowed overvoltage in the case of the continuously 
controlled output voltage power supply. The 3V margin would be dangerous at 5V output for 
powering a TTL logic and lower one could be able to trigger the thyristor crowbar under normal 
operating condition due to a disturb noise. 
 

- Avoid condensation inside the power supply, break-down could be the result. Condensation may 

occur during a period when the power supply is switched off and the ambient temperature is low. 
Always allow the power supply to dry before switching it on again. 

 
- An aggressive enviroment with acid, salt, etc. can harm the electronic components, afterwards pc-

boards may be dissolved. 

 
- Don’t remove top or bottom cover of the case under operating conditions. Dangerous voltage may 

cause a serious injury. 

 

CALIBRATION 

When there is a suspicion of incorrect display reading value of current or voltage, only qualified 
person may do a calibration.  
First needs to be adjusted reference voltage 5V source by trimer R241 on the control unit. Then may 
be adjusted correct voltage by trimer R301 and current by trimer R401. Both are placed on the display 
unit. 
 
Enclosure: Interface RS 232 instruction manual or Analogue interface instruction manual. 

 

Fig.4

SPS1000

D2

D1

Summary of Contents for SPS1000 SERIES

Page 1: ...t is limited approximately to 60A 10ms This must be taken into account at a fusing of the line outlet It is recommended to use 16A normal fuse or 10A slow one The rectified 230V AC 300V DC is chopped...

Page 2: ...nit Voltage is indicated on the 3 digit display and the current at the same time on the 3 digit display Power supply output may be turned on or off by the Disable OUTPUT switch at any time independent...

Page 3: ...PE 50Hz 230V 10 TN S Protection achieved by basic insulation and connection to earth for all conductive parts that are capable of assuming hazardous voltage if the basic isolation fails An output sec...

Page 4: ...ondition MAINTENANCE Power Supply SPS 1000 normally needs no maintenance or calibration Only care must be taken not to obstruct cooling of the unit When a unit is equipped by a dust filter which must...

Page 5: ...oad inductance will not form a serial resonant circuit The output voltage is available 2s after mains switch on This feature may be improved according to customer requirements Serial operation is allo...

Page 6: ...TTL logic and lower one could be able to trigger the thyristor crowbar under normal operating condition due to a disturb noise Avoid condensation inside the power supply break down could be the resul...

Page 7: ...after this string send character 0x0D ENTER Meaning of each symbol S beginning of message Z power supply switched ON V power supply switched OFF Tu switch OFF power supply resp his output zero voltage...

Reviews: