background image

 

1

POWER SUPPLIES SPS1000 SERIES 

CIRCUIT DESCRIPTION AND OPERATING MANUAL 

 
CIRCUIT DESCRIPTION 
 

Power Supplies SPS 1000 series are based on the primary switched AC/DC converters topology. 
Power supplies of this technology have got a high efficiency factor. Simplified functional diagram is 
shown in the fig.1. 
 

The 230 AC line voltage is rectified by a bridge rectifier „U

1

“ and smoothed by a large electrolytic 

capacitor „C

f1

“. RFI filters „F

1

“ protect the line and a load from a high frequency interference 

produced inside the power supply. When the unit is switched on, the electrolytic capacitor is charged 
via NTC resistors. Inrush current is limited approximately to 60A/10ms. This must be taken into 
account at a fusing of the line outlet. It is recommended to use 16A normal fuse or 10A slow one. The 
rectified 230V AC (300V DC) is chopped by the inverter „S“ which consists of four MOSFET 
transistors and transformed to a lower voltage. The 50kHz power converter is of full bridge type. The 
regulation of the output voltage (current) is achieved by pulse-width modulation varying duty cycle 
(D=0

÷

80%) at the constant frequency. 

F1

S

U

F2

2

U

1

t

NTC

NTC

t

C

f1

C

f2

TL

L

N

P E

U1

N1

S W ITCH

-

+

PH

+N

+P

E~

50

Hz

,2

30

V/

TN

-S

ZJ

U2

I2

RO

M

M

ROV

RS 232

"OUTP UT"

U

I

ž

ž

RE

M

O

TE

Um

I m

m

I

Um

ž

I

"OFF"

"ON"

+5V

"OFF"

"ON"

+5V

0-5V

0-5V

TR

Input

filter

Input

rect.

Inverter

Output

rect.

Output

filter

P TC1

P TC2

Fans

speed

control

:
:

Control

circuit

Display unit

Fig.1

Option

Lo

ca

l

Sw

itc

h

(Disable)

S witch

Summary of Contents for SPS1000 SERIES

Page 1: ...t is limited approximately to 60A 10ms This must be taken into account at a fusing of the line outlet It is recommended to use 16A normal fuse or 10A slow one The rectified 230V AC 300V DC is chopped...

Page 2: ...nit Voltage is indicated on the 3 digit display and the current at the same time on the 3 digit display Power supply output may be turned on or off by the Disable OUTPUT switch at any time independent...

Page 3: ...PE 50Hz 230V 10 TN S Protection achieved by basic insulation and connection to earth for all conductive parts that are capable of assuming hazardous voltage if the basic isolation fails An output sec...

Page 4: ...ondition MAINTENANCE Power Supply SPS 1000 normally needs no maintenance or calibration Only care must be taken not to obstruct cooling of the unit When a unit is equipped by a dust filter which must...

Page 5: ...oad inductance will not form a serial resonant circuit The output voltage is available 2s after mains switch on This feature may be improved according to customer requirements Serial operation is allo...

Page 6: ...TTL logic and lower one could be able to trigger the thyristor crowbar under normal operating condition due to a disturb noise Avoid condensation inside the power supply break down could be the resul...

Page 7: ...after this string send character 0x0D ENTER Meaning of each symbol S beginning of message Z power supply switched ON V power supply switched OFF Tu switch OFF power supply resp his output zero voltage...

Reviews: