1.
With no load connected, set each unit to its desired output voltage
level, and appropriate current limiting value.
2.
Set the POWER switch of each unit to OFF.
3.
Interconnect units as shown in Figure
3-10.
CAUTION
Rectifiers (and heat sinks where required)
must be connected across the output terminats
of each unit as shown in the figure. This will
prevent damage to the output capacitors. Spe
cific rectifier types are listed in Table 3-3.
4.
Set unit power switches to ON. Units operate with independently ad
justable outputs, and the power to each may be set ON or OFF sepa
rately.
UN IT 1
UN IT 2
TB 3
CR1
LOAD
See Table 3-3 for diode values
Figure 3-10 Direct Series Connections (Remote Sensing)
Operation
3-15