![Sony XCL5005 Technical Manual Download Page 46](http://html.mh-extra.com/html/sony/xcl5005/xcl5005_technical-manual_418408046.webp)
Camer
a
Con
tr
o
l
Command
s
Command Specification
46
Setting Value Accession Command
x
Setting Value Accession
[Command] RMEM
([Parameter 1]) <Setting value selection (None, 1 - 2)>
None: Camera setting value accession
1: Filter factor accession (XCL-5005 only)
2: LUT value accession
[Process] Sends the data which can be set by Serial
communication and the camera information
(version) to the camera control application.
Another command is not accepted during
transmission of data.
[Data transmission] Transmits data continuously in each
category.
The transmitting data are shown in decimal number.
The followings are transmission format and the
transmission examples.
<Transmission format>
<Category>: <Data 1>, <Data 2>, <Data 3>, ...,
<CRLF>
<Transmission example>
CA: 1.00 <CRLF>
AF: 0, 0, 1023, 1023, ..., <CRLF>
SH: 0 <CRLF>
..
.
OK <CRLF>
XCL-5005 Setting Values
Category
name
Content
Data
number
Data
CA
Camera
information
1
<Version>
AF
AFE
4
<AFE gain-left>, <AFE gain-right>, <Clamp level-left>, <Clamp level-right>
SH
Shutter
3
<Shutter speed>, <Shutter speed adjusting value>, <Shutter speed fine-adjusting>
TR
Trigger
3
<Trigger mode>, <External trigger pulse polarity>, <Trigger overlap mode>
DT
DTL
2
<DTL mode>, <Edge enhancement filter factor>
BR
Binarization
2
<Binarization mode>, <Binarization threshold value>
DG
Digital
11
<Digital gain mode>, <Digital gain step>, <Digital pedestal mode>, <Digital
pedestal>, <Automatic clamp control setting>, <Automatic clamp control
convergence value>, <Automatic clamp control correlation factor>, <Digital
clamp mode-left>, <Digital clamp-left>, <Digital clamp mode-right>, <Digital
clamp-right>
GM
Gamma
6
<Gamma mode>, <Change point (256)>, <Change point (512)>, <Change point
(1024)>, <Change point (2048)>, <Change point (3072)>
FL
Filter
1
<Filter mode>
BN
Binning
1
<Binning mode>
PT
Partial
6
<Partial scan mode>, <Partial scan read beginning position>, <Partial scan read
area>, <Partial scan offset value>, <Horizontal partial scan mode>, <Horizontal
partial scan column number>
IO
IN/OUT
7
<Trigger signal input selection>, <Grayscale output mode>, <Image output data
width>, <DC IN connector signal output setting>, <Serial communication speed
setting>, <Image output data tap>, <Flip-flop output setting>