SmartPanel Projector Driver Application Note
Sony VPL-FE100U
© 2001 SP Controls Inc. 601 Minnesota Suite 115 San Francisco, CA 94107
III. SPECIAL CONTROL NOTE:
The Sony has configuration options that must be set properly at the time of installation:
DEVICE INDEX SWITCH
: The Panel codes assume the projector network ID to 01.
To set the projector to 01:
Set the Device Index switches below the projector inputs so the first switch is 0
and the second switch is 1.
RS-232C/422A
: The projector control port must be set to RS-232C.
To set the projector to RS-232C control:
Locate the switch labeled
RS-232C RS-422A
below the projector inputs.
Be sure the projector is set to RS-232C (left position).
SIGNAL SELECT
: Signal type for inputs A, B, and C must be specified on the on-screen menus.
To specify signal types:
Summon onscreen menus using the remote control or Panel Hidden Functions.
Navigate to the
Set Settings
submenu.
Select the Input whose type you wish to specify.
Set the input to the appropriate value.
POWER SAVING
: The Sony
Power Saving
feature will automatically shut the projector off after ten
minutes if it does not receive a valid input signal. You should disable this option in the onscreen menus –
especially if the installation does not include a power current sensor.
To disable
Power Saving mode
:
Summon onscreen menus using the remote control or Panel Hidden Functions.
Navigate to the
Set Settings
submenu.
Verify that
POWER SAVING
is set to
OFF.
If not, navigate to
POWER SAVING
and set it to
OFF.
PROJECTOR BAUD RATE
: The Panel assumes the projector BAUD rate is set to 38,400 (factory
default).
To set the projector BAUD rate:
Enter the SERVICE MENU.
Verify that the RS-232C/422A value is set to 38.4 k.