background image

SmartPanel Projector Driver Application Note

Sony VPL-FE100U

© 2001 SP Controls Inc. 601 Minnesota Suite 115 San Francisco, CA 94107

[email protected]

III.  SPECIAL CONTROL NOTE:

The Sony has configuration options that must be set properly at the time of installation:

DEVICE INDEX SWITCH

: The Panel codes assume the projector network ID to 01.

To set the projector to 01:
Set the Device Index switches below the projector inputs so the first switch is 0
and the second switch is 1.

RS-232C/422A

: The projector control port must be set to RS-232C.

To set the projector to RS-232C control:
Locate the switch labeled 

RS-232C  RS-422A 

below the projector inputs.

Be sure the projector is set to RS-232C (left position).

SIGNAL SELECT

: Signal type for inputs A, B, and C must be specified on the on-screen menus.

To specify signal types:
Summon onscreen menus using the remote control or Panel Hidden Functions.
Navigate to the 

Set Settings 

submenu.

Select the Input whose type you wish to specify.
Set the input to the appropriate value.

POWER SAVING

: The Sony 

Power Saving 

feature will automatically shut the projector off after ten

minutes if it does not receive a valid input signal.  You should disable this option in the onscreen menus –
especially if the installation does not include a power current sensor.

To disable 

Power Saving mode

:

Summon onscreen menus using the remote control or Panel Hidden Functions.
Navigate to the 

Set Settings 

submenu.

Verify that 

POWER SAVING

 is set to 

OFF.

If not, navigate to 

POWER SAVING

 and set it to 

OFF.

PROJECTOR BAUD RATE

: The Panel assumes the projector BAUD rate is set to 38,400 (factory

default).

To set the projector BAUD rate:
Enter the SERVICE MENU.
Verify that the RS-232C/422A value is set to 38.4 k.

Summary of Contents for VPL-FE100U

Page 1: ...ee the SP Controls Application Note RS 232 Wire the Panel RS 232 projector port to a male DB9 as follows TX to 2 RX to 3 GND to 5 Connect this male DB9 to the projector port labeled RS 232C 422A BE SURE to set the hardware switch labeled RS 232C RS 422A located near the com port to RS 232C III Additional Projector Information The Sony has several configurable modes must be set at the time of insta...

Page 2: ...e settings your installation Selection 1 VIDEO Selection 2 S VIDEO Selection 3 INPUT A Selection 4 INPUT B Input choices available for this Driver are VIDEO S VIDEO INPUT A INPUT B and INPUT C NOTE Input type must be specified for Inputs A B and C for this projector See the Special Control Note Section III for more information NOTE INPUT B and INPUT C do not ship with the projector and must be cus...

Page 3: ...intained Relay 2 ON Momentary Relay 3 OFF Momentary Selection Momentary not Binary E Other Presets The following table specifies other default factory settings for this Driver that affect is control of the Projector Power Status Feedback Method Power Current Sensor see note 1 Control Wiring Option None see note 2 Power status verification via RS 232 Power Polling is not available for this projecto...

Page 4: ...7 6 5 4 3 2 1 This section specifies how RS 232 should be wired to the projector RS 232 should be connected to the control port labeled RS 232C 422A Connection should be as follows 1 Wire the Panel to a male DB9 as follows TX to 2 RX to 3 GND to 5 2 Connect the cable to the projector port labeled RS 232C 422A 3 Optionally an intermediate cable male DB9 to female DB9 may be used to facilitate servi...

Page 5: ... specified on the on screen menus To specify signal types Summon onscreen menus using the remote control or Panel Hidden Functions Navigate to the Set Settings submenu Select the Input whose type you wish to specify Set the input to the appropriate value POWER SAVING The Sony Power Saving feature will automatically shut the projector off after ten minutes if it does not receive a valid input signa...

Page 6: ...quence If you do not see this self test make sure power is connected correctly and that polarity is correct When I try to turn the projector on the warming indicator red LED blink The projector is in the default configured lockout state the Panel is waiting for its internal lockout timer to expire This feature protects the projector s bulb Be sure to inform your client about this behavior V TECHNI...