90
(GB)
Adjustments
Adjustments
Adjusting the Magnetic Focus
5
Press the PO key once to enter the focus adjustment mode
for the upper parts (position No. 2).
When you press the PO key, the part to be adjusted cycles
through the order as illustrated on the left. The position number is
displayed at the upper right corner.
If you press the POSITION – key, the part cycles through the reverse
order.
F O C U S A D J P O S I T I O N
- G - M G - A L L N o . 2
M G : [ 1 2 8 ]
A Q P : 1 2 8
D Q P : 1 2 8
A H P : 1 2 8
D H P : 1 2 8
SEL:
ADJ:
NEXT:
+ –
6
Adjust the AQP, DQP, AHP and DHP for position No. 2.
Press the
v
or
V
key to select the adjustment item and press the
B
or
b
key to correct the distortion of the spot.
7
Press the PO or – key to select the adjustment position and
repeat steps
5
and
6
for each position.
Adjust positions No.3 to No.9 in order.
8
Press the FUNCTION key once to exit from the SPOT SHAPE mode.
9
Display the ME-pattern with the PATTERN key.
10
Press the PO or – key to select the adjustment position No. 2
to No. 9 and adjust MG, AQP and DQP so that the letters ME are
clearly visible for every part of the screen.
Note
Do not adjust AHP and DHP for positions No. 2 to No. 9.
11
Press the CUT OFF G and B keys to display the red signal only, and
adjust AQP, DQP, AHP and DHP in the same manner as the green
signal.
12
Press the CUT OFF G and R keys to display the blue signal only, and
adjust AQP, DQP, AHP and DHP in the same manner as the green
signal.
2
Adjusting the red magnetic focus, AQP/DQP and AHP/DHP
Press the CUT OFF G and B keys to display the red signal only. Then
adjust the red magnetic focus, AQP/DQP and AHP/DHP. To adjust them,
perform the same procedure as for the green signal.
For details, see “
1
Adjusting the green magnetic focus, AQP/DQP and AHP/
DHP” on pages 87
(GB)
to 90
(GB)
.
2
4
5
6
8
3
7
9