– 13 –
KV-AR212M50/AR212M83/AR212M61
RM-W101
RM-W100
e. OTHER FUNCTION VIA REMOTE COMMANDER
7
,
-
All the data becomes the values in memory.
8
,
-
All user control goes to the standard state.
Display,
-
Service data initialization (Be sure not to use usually.)
2
,
5
Select Device or Category
3-2.
ADJUSTMENT METHOD
Item Number 000 HPOS
This explanation uses H POSITION as an example.
1. Select "000 HPOS" with the
1
and
4
buttons, or
2
and
5
.
2. Raise/lower the data with the
3
and
6
buttons.
3. Select the optimum state. (The standard is IF for PAL reception.)
4. Write with the
[MUTING]
button. (The display changes to WRITE.)
5. Execute the writing with the
-
button. (The WRITE display will be changed to red color while excuting, and back to
SERVICE.)
Example on screen display :-
Use the same method for all Items. Use
1
and
4
to select the adjustment item, use
3
and
6
to adjust, write with
[MUTING]
, then execute the write with
-
.
Note
: 1. In
[WRITE]
, the data for all items are written into memory together.
2. For adjustment items that have different standard data between 50Hz or 60Hz, be sure to use the respective
input signal after adjustment.
Adjusted with
[3]
and
[6]
buttons.
GREEN
GEOM
000
HPOS
039
SERVICE
50
VIDEO 1
write with
[MUTING]
.
GREEN
GEOM
000
HPOS
039
WRITE
50
VIDEO
1
GEOM
000
HPOS
039
WRITE
50
VIDEO
1
Write executed with
[0]
.
RED
The WRITE display
then returns to green
SERVICE
Summary of Contents for Trinitron KV-AR212M50
Page 1: ......