background image

 

 

 

INSTALLATION MANUAL 

 

 

 
 

PWM-F110 

 
 
 

Premier Mounts 

3130 E. Miraloma Avenue 

Anaheim, CA 92806 

Phone: (800) 368-9700 

Fax: (800) 832-4888 

[email protected]

 

www.mounts.com

 

 

Summary of Contents for PWM-F110

Page 1: ...INSTALLATION MANUAL PWM F110 Premier Mounts 3130 E Miraloma Avenue Anaheim CA 92806 Phone 800 368 9700 Fax 800 832 4888 mounts mounts com www mounts com ...

Page 2: ...PBL 110 Projector Mount Page 2 Installation Manual ...

Page 3: ...Table of Contents Warning Statements 4 Parts List 6 Installation Tools 6 Mounting Bracket Installation 7 Wall Stud Location 10 Installing the Flat Panel Display 14 Technical Specifications 16 Warranty 17 Contact Premier Mounts 17 Notes 18 ...

Page 4: ...age to the walls wiring or piping system Avoid Installations where there is danger of contact with over excessive dust oil smoke and tobacco smoke Failure to do so may result in fire or damage to the plasma or its internals Do not block the ventilation holes Sufficient clearance must be left in the area surrounding the plasma and wall mount to avoid blocking the vents and causing the plasma to ove...

Page 5: ... necessary to attach the enclosed mount using the enclosed hardware to the wall and to use enclosed hardware to attach to the back of the plasma television and then to attach them together As described below there are three main steps involved in the mounting process 1 Attach the six Quick Release Sleeves to the rear of the plasma television 2 Position and attach the Plasma Wall Bracket to an appr...

Page 6: ...aged please stop the installation and contact Premier Mounts 800 368 9700 Ext 224 Wall Plate 2ea 5 16 Flat Washers 8ea Griplates 8ea Mounting Brackets left and right 5 16 x 3 Lag Bolts wooden studs only 8ea Wall Bumpers 2ea M8 x 16mm Hex Head Bolt 2ea M8 x 20mm Phillips Head Screws 8ea M8 Hex Nut 2ea M4 x 16mm Phillips Head Screws 8ea Installation Tools Phillips Head Screw Driver Soft Material Bla...

Page 7: ...EL DO NOT LAY THE FLAT PANEL ON THE FLOOR WITHOUT ANY PROTECTION TO THE GLASS THE FLAT PANEL IS HEAVY AND FRAGILE AT LEAST 2 QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL 1 Once the flat panel is inverted use a measuring tape to find the center of your flat panel measuring from out...

Page 8: ...rackets stamped arrows facing out Figure 4 Figure 3 Figure 4 5 Match the center of viewing guide with the centerline you marked in step 1 Figure 5 6 The mounting brackets are designed with a center of viewing guide on the side of them Figure 6 Nylon Spacers If Applicable Inverted Flat Panel Center Mark Mounting Brackets Bottom of Flat Panel Arrows Facing Out ...

Page 9: ...aligned secure the Griplate to the flat panel Use 1 Griplate per mounting point Figure 8 NOTE The dimples of the top plates have to be facing up and the bottom dimples must be facing down DIMPLES FACING UP 3 4 DIMPLES FACING UP DIMPLES FACING DOWN DIMPLES FACING DOWN Figure 7 Figure 8 Bottom of the Flat Panel Align the Mounting Brackets Mounting Bracket Bottom of Flat Panel Center of Viewing Guide...

Page 10: ...easure from the floor to the desired viewing height and mark the wall NOTE This marking will reference the center of your flat panel display once mounted on the wall Figure 10 16 16 Figure 9 Figure 10 NOTE Although not depicted in the illustrations shown above the width of this wall mount will encompass four wall studs three wall studs if 24 apart Wood studs behind the wall structure Mark the wall...

Page 11: ...ting points through the wall plate slots on the wall 6 Level the wall plate with the reference arrow pointing up to the ceiling Figure 11 Mounting Surfaces Figure 14 Wood studs Drill eight 8 pilot holes to the marked wall 16 studs on center Figure 12 Concrete wall Drill eight 8 3 8 pilot holes to the marked wall Figure 18 16 Figure 11 Figure 12 NOTE Although not depicted in the illustrations shown...

Page 12: ... 16 lag bolts and flat washers supplied Figure 13 CAUTION Do not over tighten the lag bolts NOTE Use a minimum diameter of 5 16 x 3 long wood screws Figure 13 NOTE Although not depicted in the illustrations shown above the width of this wall mount will encompass four wall studs three wall studs if 24 apart 5 16 x 3 lag bolts and 4 flat washers 4ea Wall Plates Level ...

Page 13: ...able Figure 14 CAUTION Do not over tighten the wedge anchors bolts NOTE Use a minimum diameter of 5 16 x 2 long wedge anchors commercially available Figure 14 NOTE Although not depicted in the illustrations shown above the width of this wall mount will encompass four wall studs three wall studs if 24 apart 4 5 16 x 2 wedge anchors commercially available Wall Plate 4 5 16 x 2 wedge anchors commerci...

Page 14: ...OMMENDED FOR INSTALLATION OF THIS PRODUCT FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL 1 Raise the flat panel with the LEFT and RIGHT mounting brackets secured to the flat panel and insert the top hooks from each bracket to the rod from the wall plates Figure 15 Figure 15 Top Wall Plate ...

Page 15: ...found on the bottom of the mounting brackets Use the wall bumper to adjust your flat panel CAUTION Do not over tighten the 20 screws to the rods Figure 16 NOTE To remove the flat panel from the wall simply back off the 20 screws using a Phillips screwdriver and lift the unit of the wall carefully Figure 16 Wall Plate Wall Bumper ...

Page 16: ...age 19 Technical Specifications 16 000 406 4 16 000 406 4 1 943 49 3 5 000 127 28 000 171 2 C L 3 500 88 9 C L 5 000 127 16 000 406 4 24 290 616 97 16 000 406 4 21 790 553 4 1 245 31 75 A B C D E F G H B A F H 21 790 553 4 Figure 17 ...

Page 17: ...manship Premier Mounts is not liable for improper installation that results in damage to mounts adapters display equipment or personal injury Contact Premier Mounts In the event of missing and or damage equipment or technical questions the following information can help in the completion of the installation Customer Service 800 368 9700 Ext 224 Technical Support techsupport mounts com ...

Page 18: ...PWM F110 Installation Manual Page 18 Notes Premier Mounts 3130 E Miraloma Avenue Anaheim CA 92806 Phone 800 368 9700 Fax 800 832 4888 mounts mounts com www mounts com ...

Reviews: