– 32 –
KV-AR212M50/AR212M83/AR212M61
RM-W101
RM-W100
V. LINEARITY (VLIN), S. CORRECTION (SCOR), EW
PARABOLA/WIDTH (PW)(EWPW), AND EW
TRAPEZIUM (EWTZ) ADJUSTMENTS
1. Input Monoscope signal.
2. Activate the Service Adjustment Mode.
3. Select VLIN, SCOR, EWPW, and EWTZ with
1
and
4
.
4. Adjust with
3
and
6
for the best horizontal size.
5. Press
[MUTING]
then
-
to save into the memory.
H. PARALLELLOGRAM (HPAR), H. BOW (HBOW),
UPPER CORNER PARABOLA (UCOP) AND LOWER
CORNER PARABOLA (LCOP) ADJUSTMENTS
1. Input Monoscope signal.
2. Activate the Service Adjustment Mode.
3. Select HPAR, HBOW, UCOP, and LCOP with
1
and
4
.
4. Adjust with
3
and
6
for the best picture.
5. Press
[MUTING]
then
-
to save into the memory.
EW UPPER CORNER PARABOLA (UCOP)
EW LOWER CORNER PARABOLA (LCOP)
HORIZONTAL PARALLELOGRAM
HORIZONTAL BOW (HBOW)
EW TRAPEZIUM (EWTZ)
EW PARABOLA/WIDTH (PW) (EWPW)
S-CORRECTION (SCOR)
VERTICAL LINEARITY (VLIN)