— 18 —
KV-20S90 / 21SE43C
Function
Mode
SERVICE
Data
ID0
25
Notes:
No. 1-78 show the order that each adjustment mode may be selected while in Service Mode.
Data Range shows the range of possible setting for each Adjustment Mode.
Initial Data shows the standard settings for each Adjustment Mode.
Reg #
ITEM
FUNCTION
DATA
RANGE
INITIAL
DATA
VIDEO
AVERAGE
DATA
52
FSC
G Output On/Off
0,1
0
1
53
K-ID
B Output On/Off
0,1
0
0
54
HOSC
Horizontal VCO Oscillation Freq.
0-15
10
7
55
VSS
Vertical Sync Slice Level
0,1
0
0
56
HSS
Horizontal Sync Slice Level
0,1
0
0
57
HMSK
HMASK On/Off
0,1
1
1
58
VTMS
Select Signal VTIM Pin
0-3
0
0
59
CDMD
Vertical Count Down Mode Switching
0-3
3
3
**
60
AFC
AFC Loop Gain Switching
0-3
0
0
*
61
FIFR
Field Frequency
0-3
3
3
62
SBAS
Sub Bass
0-15
8
8
63
STRE
Sub Treble
0-15
9
9
64
SBAL
Sub Balance
0-15
13
13
65
DISP
O.S.D Display Position
0-127
15
5
66
PADJ
POWER ADJUSTMENT
0-63
51
42
67
HCHM
H SYNCH SEP. LIMIT FOR TUNER
0-127
69
69
68
HCLM
H SYNCH SEP. LIMIT FOR TUNER
0-127
16
16
69
HCHS
H SYNCH SEP. LIMIT FOR VIDEO
0-127
69
69
70
HCLS
H SYNCH SEP. LIMIT FOR VIDEO
0-127
16
16
71
ID0
0-255
SEE ID MAP
72
ID1
0-255
SEE ID MAP
73
ID2
0-255
SEE ID MAP
74
ID3
0-255
SEE ID MAP
75
ID4
0-255
SEE ID MAP
76
ID5
0-255
SEE ID MAP
77
ID6
0-255
SEE ID MAP
78
ID7
0-255
SEE ID MAP
* = TV/VIDEO = 0
** = TV = 0, VIDEO = 1
Model
Destination
ID-0
ID-1
ID-2
ID-3
ID-4
ID-5
ID-6
ID-7
KV-20S90
US
25
3
1
227
3
1
0
0
KV-21SE43C
E
17
3
1
195
115
1
0
0
ID MAP
ADJUSTMENT ITEMS (2 OF 2)
4-4. A BOARD ADJUSTMENTS
H. FREQUENCY ADJUSTMENT
1. InputTV mode (RF) with no signal.
2. Set to Service Adjustment Mode.
3. Connect a frequency counter to base of Q501
(TP-500 H. DRIVE).
4. Check H. Frequency for 15735 ± 200 Hz.
5. Press MUTING then ENTER to save into the memory.