30
Terminals
WARNING OUT Terminal
This terminal will help you to know when something
wrong has happened to the VCR during recording.
The VCR outputs a signal from WARNING OUT
terminal.
Note
To turn the clog detection function off, set CLOG
DETECT to N (no) on the SET UP 3 display.
5 V
0 V
Tape recording stops
Recording
mode
Output
signal
REC mode
Output
signal
Rewind
Recording
0 V
5 V
Tape end
Beginning
of tape
REPEAT REC mode
5 V
0 V
Rewind
Tape end
Beginning
of tape
Stop
To reset, press STOP
p
or
EJECT
6
, if the clog detection
function works and the VCR
gives warning, otherwise, press
ALL RESET.
WARNING OUT terminal
COM terminal
TAPE END OUT Terminal
When the VCR detects the tape end during recording,
the output level becomes 0 V DC. To resume the 5 V
output, press the operation button (EJECT
6
, REC
r
,
FF
)
, REW
0
or PLAY
z
, etc.).
Set TAPE END OUT to –3M or END on the SET UP
3 display.
• –3M: the time counter shows “1H57M” (about three
minutes before the tape end, when using T-120 tape)
and a signal is output from the TAPE END OUT
terminal (recording will be continued to the end of
the tape).
• END: the VCR detects the tape end.
COM terminal
TAPE END OUT terminal
2 sec.
Recording
mode
Press an
operation button.