1-18 (E)
SRX-T615
1-6. Connection of Power Cord
Use the 3-core power cord that satisfies AWG 8, 250 V rated and 40 A rated or more.
Connect the power cord to the AC IN terminal block on the rear side of this unit in the following proce-
dure.
w
.
Connection of the main power and the electric wiring work should be done by qualified electricians only.
.
Do not plug the power cord into the power supply before completing all of the following connecting
operations.
1. Remove the four screws, then remove the terminal block cover.
2. Remove the screw, then remove the cable clamp.
3. Remove the screw, then remove the ground terminal.
Screws
Terminal block cover
Screw
Screw
Ground terminal
Cable clamp