SRX-815 Chiller

Distilled water only

1.

Inject distilled water and run for 15 minutes → check flow rate and filter 

visually (Check for dirt)

2. If dirty, perform the manual cleaning according to TN (DPPJ19-210)

Start operation if not dirty (strongly recommend to add Nybrine Z1 coolant)

Coolant (Optishield)

Run for 15 minutes → check flow rate and filter visually (Check for dirt)

• If dirty, perform the manual cleaning according to TN (DPPJ19-210)  

Summary of Contents for SRX-R220

Page 1: ...Sony Projector Extended Shutdown Guidelines Shutdown Maintain and Restart Sony Projectors Sony Electronics ...

Page 2: ...Prior to Shutdown SRX R220 320 SRX R515 SRX R815 ...

Page 3: ...SRX R220 320 Exhaust Fan Turn off exhaust fan LMT 200 300 Lithium Battery Confirm BATT Alarm is not lit before shutdown If BATT Alarm is on replace the BATT ...

Page 4: ...SRX R515 Exhaust Fan Turn off exhaust fan XCT S10 XCT M10 Lithium Battery Confirm BATT Alarm is not lit before shutdown If BATT Alarm is on replace the BATT ...

Page 5: ... Recommended Leave coolant and distilled water in the projector during extended shutdown Run the projector for 2 hours a week during shut down Option 3 Leave coolant and distilled water in the projector during extended shutdown Don t touch the projector during extended shutdown Option 1 and 3 Risk of black image change Readjust by PCAB ...

Page 6: ...Returning to Service SRX R220 320 SRX R515 SRX R815 ...

Page 7: ... port and lens Clean around the lens with air 3D convergence check Single DS Check and adjust HDD condition Confirm that there is no error on the Status screen If there is no 1 7TB around 10MB contact Sony NOC to perform RAID initialization RAID builder RAID Formatter ...

Page 8: ... R515 Screening Check Check DCP Dust Check around the intake port and lens Clean around the lens with air 3D convergence check Single DS Check and adjust after adjusting the room temperature appropriately ...

Page 9: ...isually Check for dirt 2 If dirty perform the manual cleaning according to TN DPPJ19 210 Start operation if not dirty strongly recommend to add Nybrine Z1 coolant Coolant Optishield Run for 15 minutes check flow rate and filter visually Check for dirt If dirty perform the manual cleaning according to TN DPPJ19 210 ...

Page 10: ...n black image readjust Black Dark UF after taking picture except optical compensator adjustment Dust Check around the intake port and lens Clean around the lens with air 3D convergence check Single DS Check and adjust after adjusting the room temperature appropriately according to TM DPPJ18 075 ...

Page 11: ...topped for a long time two days before the server system is up and running start the UPS and complete the charging Confirm Operation Including Audio and Theater Automation Check the interlocking operation with SPL LMT 200 300 XCT S10 XCT M10 Lithium Battery Confirm absence of battery alarm replace as necessary Screening with DCP Final test ...

Page 12: ...oration Names of Sony products and services are the registered trademarks and or trademarks of Sony Corporation or its Group companies Other company names and product names are registered trademarks and or trademarks of the respective companies ...

Reviews: