8

ANALOG OUTPUT

Analog output from the D/A converter (equivalent
to XLR3-32), with pin 2 being hot.
When the level meter reads 0 dBFS, analog output is
yielded at an analog level of +24 dBu.  The output
level can be varied to the average output level
(+8 dBu/FS) of a CD player by setting an internal
jumper connector.  If you want the output level
changed, please consult your nearest Sony dealer.

WARNING!

Have this setting carried out by a Sony service

person.

To avoid electrical shock hazards that could result

in physical injury or death, never open the cover.

9

ANALOG INPUT

Analog input to the D/A converter (equivalent to
XLR3-31) at a maximum input level ranging from
–6 dBu to +24 dBu.

Note

Not to connect a microphone or musical instrument directly
to this unit, but to use a mixer or compressor/limiter to
adjust and compress their input before submitting it to the
A/D converter.

DIGITAL OUTPUT

Digital output from the A/D converter, consisting of
AES/EBU output and IEC958 output, which are
generated at the same time.

Note

The channel status of AES/EBU output is not supplied with
word-length data.

Sampling frequency (Fs) selection switch

Selects the sampling frequency of the A/D converter
from between 44.1 kHz and 48 kHz.
When the switch is set on EXT SYNC, the sampling
frequency is synchronized with the sync signal
selected with EXT SYNC selection switch 

.

!™

Word length (BIT) selection switch

Sets the word length (bit) of the digital output from
the A/D converter to 16, 20, or 24 bits.

75 

 terminator switch

Turns on or off the 75-ohm terminator of WORD
SYNC IN connector 

!∞

.

Set the switch to meet the specifications of the
equipment to which the unit is connected.

EXT SYNC selection switch

Sets the source of the reference clock that is used for
the A/D converter.
Sampling frequencies of 44.1 kHz and 48 kHz can be
synchronized.

DIGITAL INPUT:

Synchronized with the clock of the digital signal
inputting to the unit.

WORD SYNC IN:

Synchronized with external WORD SYNC input

!∞

.

!∞

External WORD SYNC IN and OUT

Connect the equipment that provides a source of the
reference clock to the IN connector.

Note

The OUT connector provides a buffered output.  The output
would not be available, therefore, when the unit is off.

Power cord

Match the white line on the cord to the “N” (neutral)
mark of the AC outlet for better sound quality.

Location and function of

parts

ANALOG OUTPUT

ANALOG INPUT

DIGITAL OUTPUT

DIGITAL INPUT

CH-1

CH-2

CH-1

AES/EBU

AES/EBU

IEC(958)

WORD SYNC

IEC(958)

CH-2

PUSH

PUSH

PUSH

IN

EXT
 SYNC

48k

20

75

44.1k 24

16

OFF

ON

DIGITAL

INPUT

EXT SYNC

BIT

Fs

OUT

Summary of Contents for SRP-DC5

Page 1: ... it ideal for use in many diverse working environments The supported sampling frequencies are 44 1 kHz and 48 kHz Digital Output Selectable from among Three Word Lengths A switch selects the word length of digital output from 24 bits 20 bits or 16 bits Internal Sampling Rate Converter An internal sampling rate converter in the D A conversion excludes jitter from digital input and makes it possible...

Page 2: ...ratiles aan de erkende vakhandel over Svenska VARNING Utsätt inte apparaten för regn och fukt för att undvika riskerna för brand och eller elektriska stötar Öppna inte höljet Det kan resultera i risk för elektriska stötar Överlåt allt reparations och underhållsarbete till fackkunniga tekniker Italiano ATTENZIONE Per evitare il pericolo di incendi o scosse elettriche l apparecchio non deve essere e...

Page 3: ...it in When shipping the unit for repair work or to another location repack it as it was On operating voltage This model is operable from both line voltages of 120 V and 230 V and is internally switched automatically to meet the line voltage whichever is available In a 120 V AC zone use the supplied plug adaptor with the power cord If a plug of any other kind is required please consult your nearest...

Page 4: ...ceived at their maximum input level and also so that their input level will be maximum 4 METER selection switch Switches the level meter between A D and D A to provide their respective metered indication 5 Sampling frequency Fs indicator Reads the sampling frequency selected with sampling frequency selection switch When the switch is set on EXT SYNC the indicator reads the sampling frequency of th...

Page 5: ...he A D converter from between 44 1 kHz and 48 kHz When the switch is set on EXT SYNC the sampling frequency is synchronized with the sync signal selected with EXT SYNC selection switch Word length BIT selection switch Sets the word length bit of the digital output from the A D converter to 16 20 or 24 bits 75 Ω terminator switch Turns on or off the 75 ohm terminator of WORD SYNC IN connector Set t...

Page 6: ...T SYNC 48 44 1k AES EBU INPUT IEC958 INPUT PLL Master Clock Gen 24 20 16 bit 44 1k 48k EXT EXT SAMPLING FREQUENCY D A 75 DSP INPUT LEVEL 24bit A D METER AES EBU OUTPUT Digital I F Digital I F A D D A ON OFF CH 1 INPUT LEVEL CH 2 METER 16 20 24 44 1k A D dBFS CH 1 CH 2 D A 48k EXT BIT Fs A D D A CONVERTER SRP DC5 60 50 40 30 20 14 10 6 2 0 OVER 350 11 44 430 482 26 4 6 6 dBu 26 4 dBu A D STATUS ...

Page 7: ...z Power consumption 20 W Operating temperature range 0 40 C Storage temperature range 20 60 C Mass approx 6 kg 13 2 lbs Dimensions approx 482 44 350 mm 19 0 1 7 13 8 in w h d excluding the projecting parts Supplied accessories Plug adaptor 1 Operating Instructions 1 In order to improve our products the specifications and external appearance are subject to change without prior notice In the event o...