background image

SEL85F14GM (FE 1.4 / 85 GM) (FE 85mm F1.4 GM)

4-5

4-3. E-MOUNT LENS ADJUSTMENT

4-3-1. Method for Starting and Finishing the E-Mount Lens Adjustment

(1) Starting the E-Mount Lens Adjustment

*  After replacing the Optical Block For Service, click the [Service Flag OFF (S)] button to release the specified flag before using the E-Mount 

Lens Adjustment. (Refer to “

1-5. NOTE ON REPLACEMENT OF OPTICAL BLOCK FOR SERVICE

”.)

*  When replacing the Main Board, if you can read the adjustment data, click the [READ] and select the [Adjustment Data Backup], Please read 

the adjustment data. (Refer to “

1-6. NOTE ON REPLACEMENT OF MAIN BOARD

”.)

*  Make sure to disconnect the AC adaptor after finishing the adjustment (including the case when stops due to an error).
*  SeusEX will start when the E-Mount Lens Adjustment is started.

1.  Turn on the power of camera.
2.  Start the E-Mount Lens Adjustment.
3.  The camera selection window opens, and select “ILCE-5000”.

*  Only ILCE-5000 cameras are available for the adjustment of the unit.

 

 Fig. 

4-3-1

4.  Click the [Connect] button and check that the connection status becomes “Connect”.

 

 

 Fig. 

4-3-2

(2) Finishing the E-Mount Lens Adjustment

1.  Click the [Disconnect] button and check that the connection status becomes “Disconnect”.

 

 

 Fig. 

4-3-3

2.  Click the [×] button on the upper right of the main window to finish.
3.  Turn off the power of camera.

4-3-2. E-Mount Lens Adjustment

Note:

 If the “PUSH ENTER” does not disappear even after pressing the ENTER key, press it again.

 

Do not touch the focus ring when performing operations on lens side, as the focus is on 

 status during adjustment.

(1) Method of Adjustment

1.  Start the E-Mount Lens Adjustment.
2.  Click the button for corresponding adjustment item in the Adjustment and Inspection.
3.  Perform the adjustment according to the instruction on the adjustment screen.

Note:

 For the adjustment method of “Flange Back (S)” that require operations on lens side, see the following sections.

4.  “FINISHED” appears on the pop-up window when the adjustment is complete, then click the [OK] button.

 

 

 Fig. 

4-3-4

Summary of Contents for SEL85F14GM

Page 1: ...INTERCHANGEABLE LENS 989677611 pdf 2016B08 1 2016 02 Published by Sony Techno Create Corporation INTERCHANGEABLE LENS 9 896 776 11 Ver Date History Contents S M Rev issued 1 0 2016 02 Official Release SEL85F14GM FE 1 4 85 GM FE 85mm F1 4 GM Ver 1 0 2016 02 US Model Canadian Model AEP Model Chinese Model Japanese Model 分解図につきましては 英語版を ご参照下さい SEL85F14GM FE 1 4 85 GM FE 85mm F1 4 GM Revision History ...

Page 2: ... sensor 2 Angle of view 1 is the value for 35mm cameras and angle of view 2 is the value for Interchangeable Lens Digital Cameras equipped with an APS C sized image sensor 3 Minimum focus is the distance from the image sensor to the subject Included items The number in parentheses indicates the number of pieces Lens 1 Front lens cap 1 Rear lens cap 1 Lens hood 1 Lens case 1 Set of printed document...

Page 3: ...ensure that no wires are pinched or contact high wattage resistors 3 Look for unauthorized replacement parts particularly transistors that were installed during a previous repair Point them out to the customer and recommend their replacement 4 Look for parts which through functioning show obvious signs of deterioration Point them out to the customer and recommend their replacement 5 Check the B vo...

Page 4: ... board straight fully into the connector until it reaches the end inside Fig 1 Fig 2 Fig 3 OK The flexible board was plugged in straight and completely NG The flexible board was plugged in crooked NG The flexible board was not plugged in completely Flexible Board Flexible Board Connector Connector Reference line Flexible Board Connector Connector Flexible Board Reference line Connector Connector F...

Page 5: ...at Plate 9139 Straight Fixed Barrel 9139 3rd Group Assy 9139 w Stator Screw Ring 9139 wj Pressure Spring wk Pressure Plate 9139 wl SSM Adjustment Washer e Plate Sheet ea Stator Assy B es Stator Holder Screw 9139 ed Stator Holder 9139 ef Rotor eg Rotor Rubber Y eh Steel Ball Holding 9139 Outer Assy Service 9139 ek Steel Ball 2 5 el 2nd Group Assy 9139 r F Spring Washer 9139 ra Dummy Frame 9139 rs F...

Page 6: ...ection Rubber GD 9139 and apply the adhesive bond B 10 to three grooves Protection Rubber GD 9139 Groove Groove Groove Apply the adhesive bond B 10 HELP02 1 Match the index of Filter Screw Barrel Assy 9139 and the aperture value scale and attach the Filter Screw Barrel Assy 9139 2 Tighten three screws Filter Screw Barrel Assy 9139 Screws Index Aperture value scale ...

Page 7: ... MF Spacer 9139 Focus Ring 9139 Apply the grease G 85 HELP04 Adhesive bond B 10 J 6082 612 A 1 Match the hole of the GD Lens Barrel Assy 9139 and the hole of the 1st Group Assy 9139 and attach the GD Lens Barrel Assy 9139 2 Attach the Back Adjustment Washer Note Attach the same quantity as the attached washers 3 Attach the GD Washer 9139 with screws 4 Apply the adhesive bond B 10 to the screw head...

Page 8: ... 10 HELP06 Grease G 85 J 6082 626 A 1 Apply the grease G 85 to the specified locations of Rear Barrel Assy 9139 Rear Barrel Assy 9139 Apply the grease G 85 Apply the grease G 85 2 Attach the Iris Ring Spacer 9139 to the Rear Barrel Assy 9139 and apply the grease G 85 to the specified locations Rear Barrel Assy 9139 Iris Ring Spacer 9139 Rear Barrel Assy 9139 Apply the grease G 85 HELP07 Grease G 8...

Page 9: ... Assy 9139 Apply the grease G 345 Outer Assy 9139 Apply the grease G 345 Apply the grease G 345 4 Attach the Steel Ball 2MM to the Iris Ring Assy 9139 Steel Ball 2MM Iris Ring Assy 9139 5 Move the slider to the marked 6 Match the 1 4 of Iris Ring Assy 9139 and the index and attach the Iris Ring Assy 9139 At that time the slider is fit into the groove of the Iris Ring Assy 9139 Iris Ring Assy 9139 ...

Page 10: ...x portion of the CL 1040 board and attach it to the Outer Assy Service 9139 Install the Flexible Board Stator Assy B as shown in the figure below CL 1040 Board Flexible Board Stator Assy B Hole Convex portion Flexible Board Stator Assy B HELP09 Adhesive bond B 10 J 6082 612 A 1 Pass the Main FPC Assy 9139 through the small hole of Outer Assy Service 9139 2 Pass the Flexible Board Stator Assy B thr...

Page 11: ...e MR Encoder 1740 MR Encoder 1740 Apply the grease G 85 All circumference HELP12 1 Attach the Main FPC Assy 9139 with five claws and the hook 2 Connect the GMR Flexible Assy to the connector of Main FPC Assy 9139 and attach it to the hook Hook Hook Claw Claw Main FPC Assy 9139 GMR Flexible Assy Connector Main FPC Assy 9139 HELP13 Adhesive bond B 10 J 6082 612 A Grease FT 210 9 913 200 37 1 Apply t...

Page 12: ...adhesive bond B 10 to the groove of Sta tor Screw Ring 9139 which is not affected the groove of Straight Fixed Barrel 9139 OK NG Straight Fixed Barrel 9139 Stator Screw Ring 9139 Stator Screw Ring 9139 Groove 4 locations Stator Screw Ring 9139 Apply the adhesive bond B 10 HELP14 1 Match the Flexible Board of Stator Assy B to the groove of Straight Fixed Barrel 9139 and attach the Stator Assy B Fle...

Page 13: ...d Stator Holder Screw 9139 Stator Holder 9139 Rotor Rotor Rubber Y Stator Holder Screw 9139 Wide groove Wide convex portion 2 Apply the adhesive bond B 10 to the specified locations Apply the adhesive bond B 10 Straight Fixed Barrel 9139 Narrow groove Wide groove HELP16 1 Attach the Flat Plate 9139 to the Cam Barrel 9139 Cam Barrel 9139 Flat Plate 9139 ...

Page 14: ... Wide concave portion HELP17 Grease FT 210 9 913 200 37 1 Apply the grease FT 210 to the overall of Steel Ball Holding 9139 2 Attach the Flat Plate 9139 to the Straight Fixed Barrel 9139 3 Attach the Steel Ball Holding 9139 to the Straight Fixed Barrel 9139 4 Insert the fifty Steel Balls 2 5 to the hole of Steel Ball Holding 9139 OK NG Apply the grease FT 210 Apply to the both sides Steel Ball 2 5...

Page 15: ... Selection Parts BACK WASHER 9139 Note 3 22 A 2092 598 A CL 1041 COMPL SERVICE 23 A 2124 451 A REAR BARREL ASSY 9139 SERVICE 24 4 300 115 21 TAPPING 1 7 CH 25 Selection Parts IRIS RING SPACER 9139 Note 3 26 A 2073 556 A IRIS RING ASSY 9139 27 4 570 102 01 FPC HOLDER 9139 28 4 300 113 11 TAPPING 1 7 CH 29 A 2085 916 A CL 1040 MOUNT BOARD ASSY 30 1 894 991 11 LF 2141 FLEXIBLE PWB DC9139 31 4 570 986...

Page 16: ... 63 4 568 761 01 STATOR HOLDER 9139 64 4 577 330 01 ROTOR RUBBER Y 65 4 572 778 01 FLAT PLATE 9139 66 4 568 751 01 STEEL BALL HOLDING 9139 67 4 568 759 01 STEEL BALL 2 5 68 2 691 576 02 SHEET STATOR HOLD SHEET B 69 4 300 115 21 TAPPING 1 7 CH 3 1 3 SELECTION PARTS Ref No 21 These washers are provided for Photographic Resolving Power Partial Blur Adjustment Change the thickness t according to resul...

Page 17: ...ions GERMAN DUTCH SWEDISH ITALIAN PORTUGUESE 905 4 575 277 21 Operating Instructions RUSSIAN ARABIC TRADITIONAL CHINESE KOREAN UKRAINIAN 905 4 575 277 31 Operating Instructions SIMPLIFIED CHINESE Ref No Part No Description 951 X 2592 340 1 レンズフロントキャップ 952 4 159 701 03 レンズリヤキャップ 953 X 2592 145 1 レンズフード 954 4 581 459 12 レンズケース 955 4 575 277 01 取扱説明書 日本語 英語 フランス語 スペイン語 955 4 575 277 11 取扱説明書 ドイツ語 オラン...

Page 18: ...ris Close z z z Lens Sleep z z z z z Optical Axis Check Adjustment z z z z z Photographic Projective Resolving Power Check z z z z z Photographic Projective Resolving Power Adjustment z z z z z Flange Back Check z z z z z Adjusting Height of Ultrasonic Motor z z z z z Table 4 1 1 4 1 2 List of Service Tools and Equipments Lens adjustment program E Mount_Lens_Adjustment_ E zip Adjustment Applicatio...

Page 19: ...r J 6082 606 A E mount attachment J 6082 798 A 20 30 40 50 60 70 80 90 0 10 A mount attachment J 6082 607 A Extension Jig 47 00 mm J 6082 797 A Flange back gauge 43 50 mm J 6082 608 A SSM Height Adjustment Jig J 6082 691 A Resolution Check Chart ILC J 6082 813 A J 16 0 8 0 6 0 5 0 3 0 3 0 5 0 6 0 8 Fig 4 1 1 Note 1 Personal computer The SeusEX must be installed in the PC OS Windows Vista 7 RAM 256...

Page 20: ... Run time Within 10 mm In the case of fixed focal lens In the case of zoom lens Within 10 mm Flange back adjustment jig J 6082 563 A FB Adjustment chart or Siemens star chart J 6080 875 A AC adaptor AC PW20 1 487 963 12 EXCEPT US CND 1 487 963 22 US CND Flange back adjustment jig Flange back adjustment jig Fig 4 1 3 A flange back adjustment jig and a flange back adjustment chart are necessary for ...

Page 21: ...ng Just me Only for the user who logs in the PC now Fig 4 2 3 Fig 4 2 4 Fig 4 2 5 7 Create a shortcut icon of the E Mount Lens Adjustment Adjustment Application for Service on the desk top Fig 4 2 6 4 2 1 Procedure of Installing the E Mount Lens Adjustment 4 2 INSTALLING PROCEDURE 1 Download the lens adjustment program E Mount Lens Adjustment zip 2 Double click the setup exe file 3 The installer s...

Page 22: ...LCE 5000 Only ILCE 5000 cameras are available for the adjustment of the unit Fig 4 3 1 4 Click the Connect button and check that the connection status becomes Connect Fig 4 3 2 2 Finishing the E Mount Lens Adjustment 1 Click the Disconnect button and check that the connection status becomes Disconnect Fig 4 3 3 2 Click the button on the upper right of the main window to finish 3 Turn off the power...

Page 23: ...yed on the Message History window Click the Clear button the histories displayed on the Message History window will be deleted Fig 4 3 5 2 Adjustment method of Lens Device S About Lens Device S item the operation of lens side is needed Note Be sure to move the zoom to TELE end start the adjustments When operating the lens operate it while holding a camera body by hand well So that a lens does not ...

Page 24: ...s scale A and push the ENTER key Fig 4 3 11 7 Set the iris ring click switch to on match the iris ring to the iris scale A and push the ENTER key Fig 4 3 12 8 According to the instructions of the screen adjust it from scale 1 4 in order of A Fig 4 3 13 9 After START is displayed push the ENTER key Fig 4 3 14 10 After Push the FH Button Pos1 is displayed push the focus hold button Fig 4 3 15 ...

Page 25: ...4 3 17 13 After FOCUS SSM Noise Check START is displayed push the ENTER key Fig 4 3 18 14 Confirm that abnormal noise from a lens is not heard Push the ENTER key Fig 4 3 19 15 LENS DEVICE FOCUS SSM Noise CHECK COMP is displayed Fig 4 3 20 16 Recording the adjustment data and releasing the adjustment mode are performed automatically by pushing the ENTER key After processing FINISHED is displayed ...

Page 26: ...MENT OK is displayed Fig 4 3 22 3 Recording the adjustment data and releasing the adjustment mode are performed automatically by pushing the ENTER key After processing FINISHED is displayed 4 Adjustment method of Flange Back S About Flange Back S item the operation of lens side is needed Note Be sure to move the zoom to TELE end start the adjustments When operating the lens operate it while holdin...

Page 27: ...focus mode manual focus shooting mode A mode iris value F1 4 3 Set the iris value to F8 4 Confirm that the image change is less than 0 02 mm when setting the iris value to F8 5 Adjustment method of ROM Check About ROM Check item the operation of lens side is needed Note Be sure to move the zoom to TELE end start the adjustments When operating the lens operate it while holding a camera body by hand...

Page 28: ...achment J 6082 798 A Flange Back Gauge 43 50 mm J 6082 608 A Extension Jig 47 00 mm J 6082 797 A Camera General E mount digital single lens reflex camera Preparations 1 Set the equipment as shown in the Fig 4 5 1 Flange back gauge 43 50 mm A mount attachment Objective lens 10x Dial Gauge Min scale 0 01 mm Scale ring Eyepiece lens 7x Eyepiece ring Fig 4 5 1 2 Looking through the eyepiece lens turn ...

Page 29: ...and D and ensure that it is within the specification CB value C D 1 1 2 2 5 4 AS E D F H G I CB Fig 4 5 5 Specification Reference CB Center Blur 0 04 mm or less AS Astigmatism 0 03 mm or less Table 4 5 1 7 If the specifications of CB and AS are not satisfied perform the 4 5 2 Optical Axis Adjustment 4 4 1 Adjusting Procedure 4 5 1 Optical Axis Check 1 Attach the E mount attachment to the A mount a...

Page 30: ...he 100 mm rear from that position 1125mm x 750mm 3 2 2015 12 15 LENS Gp 0 8 0 6 0 5 0 3 0 3 0 5 0 6 0 8 Fig 4 6 1 4 4 1 Adjusting Procedure Checking Method 1 Set to manual focus on status that the Preparations condition 2 Focus and shoot with self timer 3 Keep focusing as step 2 change the object distance to the shooting distance position 100 mm of step 1 then shoot two times with self timer 4 Che...

Page 31: ...nd B 10 Preparation 1 Remove it to the 3rd Group Assy 9139 referring to the 2 1 DISASSEMBLY and set it to the half completion state 2 Remove the Stator Screw Ring 9139 and the Pressure Spring Stator Screw Ring 9139 Pressure Spring Fig 4 9 1 4 4 1 Adjusting Procedure Adjustment method 1 Set the SSM height adjustment measurement jig and SSM height adjustment harpoon jig on the Pressure Plate 9139 2 ...

Page 32: ...ht adjustment jig cap and adjust the Stator Screw Ring 9139 to satisfy the adjustment value adjustment value 3 5 0 05 mm 9 After completing the adjustment apply the adhesive bond B 10 to the groove of Stator Screw Ring 9139 which is not concern to the groove of Straight Fixed Barrel 9139 OK NG Straight Fixed Barrel 9139 Stator Screw Ring 9139 Stator Screw Ring 9139 Groove 4 locations Stator Screw ...

Page 33: ...い 2 指定部品のご使用を セッ トの部品は難燃性や耐電圧など安全上の特性を持ったものとなっています 従って交換部品は 使用されていたものと同じ特性の部品を使用してください 特に回路図 部品表に0印で指定されている安全上重要な部品は必ず指定のものをご使用ください 3 部品の取付けや配線の引きまわしはもとどおりに 安全上 チューブやテープなどの絶縁材料を使用したり プリント基板から浮かして取付けた部品があります また内部配線は引きまわしやクランパによって発熱部品や高圧部品に接近しないよう配慮されていますので これらは必ずもとどおりにし てください 4 サービス後は安全点検を サービスのために取外したネジ 部品 配線がもとどおりになっているか またサービスした個所の周辺を劣化させてしまったところがない かなどを点検し 安全性が確保されていることを確認してください 5 チップ部品交換時の注意 取...

Page 34: ...J 6082 755 A 作業時の注意 フレキシブル基板の導電面に汚れやごみなどがないことを確認してください フレキシブル基板の導電面を素手で触れないようにしてください フレキシブル基板は コネクターの奥までまっすぐに差し込んでください 図1 図2 図3 参照 OK 奥までまっすぐに差し込んである NG 斜めに差し込んである NG 差し込み不十分 コネクター コネクター フレキシブル 基板 基準線 フレキシブル 基板 コネクター コネクター 基準線 フレキシブル 基板 フレキシブル 基板 コネクター コネクター 基準線 フレキシブル 基板 フレキシブル 基板 図1 図2 図3 コネクターの開閉部を開ける際 A方向に開け過ぎないようにし てください コネクターの開閉部を閉じる際 フレキシブル基板を矢印B方向 に押しながら 開閉部を均一に押してください 開閉部 コネクター フレキシブル基板 A...

Page 35: ... 9139 平板起動盤 9139 直進固定環 9139 3群部組 9139 w ステータ押さえリングネジ 9139 wj 加圧バネ wk 加圧板 9139 wl SSM調整ワッシャー e 板 シート ea ステータASSY B es ステータ回り止めリングネジ 9139 ed ステータ回り止め環 9139 ef ローター eg ローターラバーY eh 鋼球保持器 9139 外装部組 サービス 9139 ek 鋼球 2 5 el 2群部組 9139 r F付勢用ワッシャ 9139 ra ダミー枠 9139 rs 前保持環 9139 MRエンコーダー 1740 wsアイリス ATS 40B F1 wd基板ゴムブッシュB 9109 ej クリックレバー 9139 スライドレバー 防滴シートB 9133 フォーカスフォールドボタン 9126 フォーカスフォールド ボタン座 フォーカスフォールド ゴ...

Page 36: ...F1 4 GM HELP 取り付け時の注意や グリス塗布方法などを記載しています HELP01 ボンド B 10 J 6082 612 A 1 GD防滴ゴム 9139 を取り付け 溝3箇所にボンド B 10 を塗布する GD防滴ゴム 9139 溝 溝 溝 ボンド B 10 を塗布 HELP02 1 フ ィルターネジ環ASSY 9139 の指標と絞り値目盛りの位置を合わせて取り付ける 2 ネジ3本で取り付ける フィルターネジ環 ASSY 9139 ネジ 指標 絞り値目盛り ...

Page 37: ...リス G 85 を塗布 全周に塗布 2 フォーカス操作環 9139 にMFスペーサ 9139 を取り付けた後 指示部にグリス G 85 を塗布する MFスペーサ 9139 フォーカス操作環 9139 グリス G 85 を塗布 HELP04 ボンド B 10 J 6082 612 A 1 GDレンズ枠ASSY 9139 の穴と1群部組 9139 の穴の位置を合わせて取り付ける 2 バックワッシャを取り付ける 注意 取り付いていた量と同じ量を元の位置に取り付けてください 3 ネジでGDワッシャー 9139 を取り付ける 4 ネジ頭にボンド B 10 を塗布する ネジ GDワッシャー 9139 GDワッシャー 9139 ネジ バックワッシャ バックワッシャ 溝 2つ 溝 1つ 穴 1つ 1群部組 9139 MRエンコーダ 1740 GDレンズ枠ASSY 9139 穴 2つ 穴 2つ ボンド B ...

Page 38: ...テータASSY B 穴 2か所 穴 1か所 ボンド B 10 を塗布 HELP06 グリス G 85 J 6082 626 A 1 後外装部組 9139 の指示部にグリス G 85 を塗布する 後外装部組 9139 グリス G 85 を塗布 グリス G 85 を塗布 2 後外装部組 9139 にア イリスリングスペーサー 9139 を取り付けた後 指示部にグリス G 85 を塗布する 後外装部組 9139 アイリスリングスペーサー 9139 後外装部組 9139 グリス G 85 を塗布 HELP07 グリス G 85 J 6082 626 A グリス G 345 J 6082 755 A 1 ア イリスリング部組 9139 の指示部にグリス G 85 を塗布する アイリスリング部組 9139 グリス G 85 を塗布 グリス G 85 を塗布 ...

Page 39: ...0 アイリスリング部組 9139 3 指示部にグリス G 345 を塗布する アイリスリング部組 9139 グリス G 345 を塗布 外装部組 9139 グリス G 345 を塗布 グリス G 345 を塗布 4 スチールボール2MMをア イリスリング部組 9139 に取り付ける スチールボール 2MM アイリスリング部組 9139 5 スライ ダーを マークまで移動する 6 ア イリスリング部組 9139 を 1 4 と指標の位置を合わせながら 取り付ける その際 ア イリスリング部組 9139 の溝にスライ ダーがはまること アイリスリング部組 9139 スライダー マーク 指標 1 4 ...

Page 40: ... フレキシブル基板 ステータASSY B フレキシブル基板 ステータASSY B CL 1040基板 OK NG CL 1040基板 3 CL 1040基板の穴と凸部を合わせて基板を取り付ける その後 フレキシブル基板 ステータASSY B を図のように処理する CL 1040基板 フレキシブル基板 ステータASSY B 穴 凸部 フレキシブル基板 ステータASSY B HELP09 ボンド B 10 J 6082 612 A 1 外装部組 サービス 9139 の小さい穴にメインフレキASSY 9139 を通す 2 外装部組 サービス 9139 の大きい穴にフレキシブル基板 ステータASSY B を通す 3 外装部組 サービス 9139 の溝にメインフレキASSY 9139 のコネクタ部を挿入する 4 ネジ4本を取り付ける 5 ネジ頭にボンド B 10 を塗布する 外装部組 サービス 91...

Page 41: ... 85 J 6082 626 A 1 MRエンコーダー 1740 のギア部にグリス G 85 を塗布する MRエンコーダー 1740 グリス G 85 を塗布 全周に塗布 HELP12 1 メインフレキASSY 9139 をツメ5箇所とフックで取り付ける 2 GMRフレキASSYをメインフレキASSY 9139 のコネクターに接続し フックに取り付ける フック フック ツメ ツメ メインフレキASSY 9139 GMRフレキASSY コネクター メインフレキASSY 9139 HELP13 ボンド B 10 J 6082 612 A グリス FT 210 9 913 200 37 1 加圧バネの両面にグリス FT 210 を塗布する 加圧バネ 加圧バネ グリス FT 210 を塗布 ...

Page 42: ...ネジ 9139 を時計方向に回して取り付ける ステータ押さえリングネジ 9139 加圧バネ 4 4 9 超音波モータの高さ調整 の後 直進固定環 9139 の溝に影響しないステータ押さえリングネジ 9139 の溝にボンド B 10 を塗布 する OK NG 直進固定環 9139 リングネジ 9139 リングネジ 9139 溝 4か所 リングネジ 9139 ボンド B 10 を塗布 HELP14 1 ステータASSY Bのフレキシブル基板と溝の位置を合わせて取り付ける フレキシブル基板 ステータASSY B 直進固定環 9139 大きい溝 ...

Page 43: ...15 ボンド B 10 J 6082 612 A 1 ローターラバーY ローター ステータ回り止め環 9139 ステータ回り止めリングネジ 9139 の順に取り付ける ステータ回り止め環 9139 ローター ローターラバーY ステータ回り止めリングネジ 9139 広い溝 広い凸部 2 指示部にボンド B 10 を塗布する ボンド B 10 を塗布 直進固定環 9139 狭い溝 広い溝 HELP16 1 カム環 9139 に平板軌道盤 9139 を取り付ける カム環 9139 平板軌道盤 9139 ...

Page 44: ...る 3 下に押しながら 反時計回りに回転させて取り付ける カム環 9139 直進固定環 9139 切り欠き 広い凹部 HELP17 グリス FT 210 9 913 200 37 1 鋼球保持器 9139 の全面にグリス FT 210 を塗布する 2 直進固定環 9139 に平板軌道盤 9139 を取り付ける 3 直進固定環 9139 に鋼球保持器 9139 を取り付ける 4 鋼球 2 5 50個を鋼球保持器 9139 の穴に入れる OK NG グリス FT 210 を塗布 両面に塗布する 鋼球 2 5 鋼球保持器 9139 平板軌道盤 9139 直進固定環 9139 ...

Page 45: ...m Check Adjustment execute Check Iris Close Lens Sleep 光軸の確認 調整 撮影 投影解像力の確認 撮影 投影解像力の調整 フランジバックの確認 超音波モータの高さ調整 Table 4 1 1 4 ADJUSTMENTS 4 1 2 使用機器 治工具リスト レンズ調整プログラム E Mount Lens Adjustment J zip Adjustment Application for Service レンズ調整プログラム BLG TestProgramV exe B L コントロールボックス J 6082 774 A D sub 15ピンケーブルを付属 ACコード 市販品 RS 232Cケーブル D sub 9ピン オス 固定ねじ付き D sub 9ピン メス 固定ねじ付き ストレートタイプ 市販品 USB to シリアルケーブル ...

Page 46: ... mmコリメータ 110V J 6082 604 A 240V J 6082 604 B Note 2 フランジバック 測定器 J 6082 606 A Eマウント アタッチメント J 6082 798 A Aマウント アタッチメント J 6082 607 A 延長治具 47 00 mm J 6082 797 A フランジバック ゲージ 43 50 mm J 6082 608 A SSM高さ調整治具 J 6082 691 A 解像度チェックチャート ILC J 6082 813 A J 16 0 8 0 6 0 5 0 3 0 3 0 5 0 6 0 8 Fig 4 1 1 Note 2 1000 mm コリ メータのチャートは Fig 4 1 2 のように取り付けてく ださい マークを合わせる 1000 mmコリメータ チャート Fig 4 1 2 Note 1 パーソナルコンピュータ ...

Page 47: ...rk 2 0 NET Framework 2 0がインストールされていない PCには レンズ調整プログラムインストール時にイ ンストールされます USBケーブル 1 829 868 41 カメラ ILCE 5000 三脚 任意 被検レンズ ACアダプター AC PW20 1 487 963 12 EXCEPT US CND 1 487 963 22 US CND フランジバック 調整用治具 J 6082 563 A FB調整チャート or ジーメンススター チャート J 6080 875 A HASPキー USBコネクタへ USBコネクタへ AC 三脚ネジへ Fig 4 1 3 Flange Back S 調整には フランジバック調整用治具およびFB調整チャートが必要となります FB調整チャートは用紙いっぱいにチャートが印刷され かつ規格の大きさになるように拡大して印刷してください 規格値...

Page 48: ...ブルクリックする Fig 4 2 1 3 インストーラー画面が表示されるので 次へ ボタンをクリックする Fig 4 2 2 4 インストール先フォルダを選択する画面が表示されるので インストールするユーザーを選択して 次へ ボタンをクリックす る すべてのユーザー インストールを行うPC内すべてのユーザーにインストール このユーザーのみ 現在ログインしているユーザーのみにインストール Fig 4 2 3 5 インストール開始画面が表示されるので 次へ ボタンをクリックし インストールを開始する Fig 4 2 4 6 インストールが完了すると 下記画面が表示されるので 閉じる ボタンをクリックする Fig 4 2 5 7 デスクトップにE Mount Lens Adjustment Adjustment Application for Service のショートカットアイコンが作成される...

Page 49: ...stmentを起動する 3 カメラ選択画面が表示されるので ILCE 5000 を選択する 本機の調整で使用できるカメラはILCE 5000のみです Fig 4 3 1 4 Connect ボタンをクリックし Connection Statusが Connect に変化することを確認する Fig 4 3 2 2 E Mount Lens Adjustmentの終了 1 Disconnect ボタンをクリックし Connection Statusが Disconnect に変化することを確認する Fig 4 3 3 2 メインウインドウ右上の ボタンをクリックし E Mount Lens Adjustmentを終了する 3 カメラの電源を切る 4 3 2 E Mount Lens Adjustment調整 注意 ENTERを押しても PUSH ENTER が消えない場合は 再度ENTERを押...

Page 50: ...側での操作が必要となります 注意 必ずズームをTELE端にしてから 調整を開始してください レンズ操作時は レンズの位置が動かないように カメラ本体等をしっかりと手で保持しながら操作してください その際に フォーカスリン グには絶対に触れないでください 1 Lens Device S ボタンをクリックするとSTART画面が表示されるので 調整の準備が完了したらENTERキーを押す Fig 4 3 6 2 MF ROTATION START と表示されたらENTERキーを押す Fig 4 3 7 3 PLEASE ROTATE MF RING と表示されたらフォーカスリングを連続的に一方向へ回転させ続ける Fig 4 3 8 4 調整が完了すると MF ROTATION STOP と表示が出るので リングの回転を止めてENTERキーを押す Fig 4 3 9 ...

Page 51: ...1 4 に合わせ ENTERキーを押す Fig 4 3 10 6 絞りリングを絞り目盛 A に合わせ ENTERキーを押す Fig 4 3 11 7 絞りリングクリック切換スイッチをONにして絞りリングを絞り目盛 A に合わせ ENTERキーを押す Fig 4 3 12 8 画面の指示に従いながら 目盛り 1 4 から A の順に調整を行う Fig 4 3 13 9 START と表示されたらENTERキーを押す Fig 4 3 14 10 Push the FH Button Pos1 と表示されたらフォーカスホールドボタンを押す Fig 4 3 15 ...

Page 52: ... 16 12 Select the AF と表示されたらフォーカスモードスイッチをAF側にする Fig 4 3 17 13 FOCUS SSM Noise Check START と表示されたらENTERキーを押す Fig 4 3 18 14 レンズから異音が聞こえないことが確認できたら ENTERキーを押す Fig 4 3 19 15 LENS DEVICE FOCUS SSM Noise CHECK COMP と表示される Fig 4 3 20 16 ENTERキーを押すと自動的に調整データの記録と調整モードの解除が行われ 処理が終わると FINISHED のメッセージが表示さ れる ...

Page 53: ...21 2 調整が完了すると LENS DEVICE FOCUS SSM LOAD ADJUSTMENT OK と表示される Fig 4 3 22 3 ENTERキーを押すと自動的に調整データの記録と調整モードの解除が行われ 処理が終わると FINISHED のメッセージが表示さ れる 4 Flange Back S の調整方法 Flange Back S の項目については レンズ側での操作が必要となります 注意 必ずズームをTELE端にしてから 調整を開始してください レンズ操作時は レンズの位置が動かないように カメラ本体等をしっかりと手で保持しながら操作してください その際に フォーカスリン グには絶対に触れないでください 1 Flange Back S ボタンをクリックすると Please Set the Brightness 30 60cd m 2 が表示されるので 輝度を設定した...

Page 54: ...ピントを合わせ1000 mmコリメータで 無限 端F1 4の像面位置を測定する フォーカスモード マニュアルフォーカス 撮影モード Aモード 絞り値 F1 4 3 絞り値をF8まで絞る 4 絞った時の像面変動が0 02 mm以内であることを確認する 5 ROM Check の調整方法 ROM Check の項目については レンズ側での操作が必要となります 注意 必ずズームをTELE端にしてから 調整を開始してください レンズ操作時は レンズの位置が動かないように カメラ本体等をしっかりと手で保持しながら操作してください その際に フォーカスリン グには絶対に触れないでください 1 ROM Check ボタンをクリックすると APERTURE RING MODE SW set to CLICK ON が表示されるので 絞りリングクリック 切換スイッチをONにしたらENTERキーを押す Fig...

Page 55: ... 6082 606 A Aマウントアタッチメント J 6082 607 A Eマウントアタッチメント J 6082 798 A フランジバックゲージ 43 50 mm J 6082 608 A 延長治具 47 00 mm J 6082 797 A カメラ Eマウントデジタル一眼レフカメラ全般 準備 1 測定器をFig 4 5 1のように設定する フランジバックゲージ 43 50 mm Aマウントアタッチメント 対物レンズ 10x ダイヤルゲージ 最小目盛り 0 01 mm 目盛りリング 接眼レンズ 7x 視度調節リング Fig 4 5 1 2 フランジバック測定器の視度調節リングを回し 接眼レンズ内の十字線または目盛りがはっきりと見えるように調節する 3 フランジバックゲージ 43 50 mm をAマウントアタッチメントに密着させ 保持する 4 フランジバックゲージに光を投じながらフランジ...

Page 56: ...読み取る D 6 CB値を算出 C と D の差分絶対値 し 規格値以内かどうかを確認する CB値 C D 1 1 2 2 5 4 AS E D F H G I CB Fig 4 5 5 規格値 参考値 CB センターブレ 0 04 mm 以下 AS 軸上アス 0 03 mm 以下 Table 4 5 1 7 CBとASの規格値を満足していない場合は 4 5 2 光軸の調整 を行う 4 4 1 調整手順 4 5 1 光軸の確認 1 AマウントアタッチメントにEマウントアタッチメントを取り付け フランジバック測定器に取り付ける 注意 Eマウントアタッチメントに取り付けるカメラは 以下のように設定してください フォーカスモード マニュアルフォーカス 手ブレ OFF 2 対物レンズ 10x に延長治具 47 00 mm を取り付け フランジバック測定器に取り付ける 3 フランジバック測定器に被検...

Page 57: ...置からさらに100 mm後ろに移動させる 1125mm x 750mm 3 2 2015 12 15 LENS Gp 0 8 0 6 0 5 0 3 0 3 0 5 0 6 0 8 Fig 4 6 1 4 4 1 調整手順 確認方法 1 準備 の状態で マニュアルフォーカスに設定する 2 ピントを合わせて セルフタイマーで撮影する 3 ピントは手順2の状態のままで 撮影距離を手順1の位置から 100 mmの位置にし 2枚セルフタイマーで撮影する 4 撮影画像3枚の結果から 周辺の解像がFig 4 6 2で示す基準を満たしているか確認する 注意 中心のサークルが解像しているこ とを確認し 周辺のサークルは上下左右が均等に解像しているこ とを確認してく ださい 任意のサークルと その直径方向で反対にあるサークルは同等に解像されているこ と Adobe Photoshop等を使用して 解像の確認...

Page 58: ...ジバックの確認 を実行する 2 撮影した動画を液晶モニタで再生する 著しいピントボケ 中心像移動 像ユレ 像トビがある場合は サービス専用光学ブロッ クを交換してください 4 4 1 調整手順 4 9 超音波モータの高さ調整 使用機器 SSM高さ調整治具 SSM 高さ調整重り治具 SSM 高さ調整測定治具 ボンド B 10 準備 1 2 1 DISASSEMBLY を参照し 3群部組 9139 までを取り外し 半完成状態のレンズにする 2 ステータ押さえリングネジ 9139 と加圧バネを取り外す ステータ押さえリングネジ 9139 加圧バネ Fig 4 9 1 4 4 1 調整手順 調整方法 1 加圧板 9139 の上にSSM高さ調整治具とSSM高さ調整重り治具を取り付ける 2 SSM高さ調整重り治具の両側に下記の条件を満たすように重りを入れる 1400 g SSM高さ調整治具 SSM高さ...

Page 59: ...さ調整治具を取り付ける SSM高さ調整測定治具 SSM高さ調整治具 Fig 4 9 3 8 SSM高さ調整治具の中心付近にSSM高さ調整測定治具を当て 調整値になるようにステータ押さえリングネジ 9139 を回して 調整する 調整値 3 5 0 05 mm 9 直進固定環 9139 の溝に影響しないステータ押さえリングネジ 9139 の溝にボンド B 10 を塗布する OK NG 直進固定環 9139 リングネジ 9139 リングネジ 9139 溝 4か所 リングネジ 9139 ボンド B 10 を塗布 Fig 4 9 4 4 4 1 調整手順 ...