5-23
SEL1635GM
5-5. E-MOUNT LENS ADJUSTMENT
Equipment and Tools
• Personal Computer (See Note 1, 2)
• HASP key (SeusEX)
• Micro USB cable
• Lens adjustment program (E-Mount Lens Adjustment.zip)
• Flange back adjustment jig
• FB adjustment chart (10 mm)
• Siemens star chart
• Camera (ILCE-5000, ILCE-6300) (See Note 3)
Note 1:
Personal computer must have the condition that Windows 7
runs normally and USB is connectable.
Note 2:
The Excel must be installed in the PC.
Note 3:
When performing the focus shift adjustment, use the ILCE-
6300. When performing the other items, use the ILCE-5000.
5-5-1. Preparations
Set the equipment and the lens to be tested as shown below.
Flange back
adjustment jig
Within 10 mm
Lens to be tested
Flange back
adjustment jig
FB adjustment
chart
When the subject is a flange back adjustment jig
Lens to be
tested
Siemens star
chart
Image sensor
position mark
Siemens star
chart
When the subject is a siemens star chart
370 mm
Camera
Tripod
Lens to
be tested
AC adaptor
AC
To tripod
screw
Personal
computer
USB cable
HASP key
To USB connector
To USB
connector
(1) Installation
For adjustment of the SEL1635GM, prepare a version 1.4.1.6 or high-
er of the lens adjustment program (E-Mount Lens Adjustment.zip).
Note:
Perform the installation by administrator privileges.
Do not change the installation folder.
Procedure of Installation
1. Download the lens adjustment program (E-Mount Lens Adjust-
ment.zip).
2. Double click the setup.exe file.
3. The installer screen appears, then click the [Next] button.
4. The folder select screen appears, then select the installing user
and click the [Next] button.
Everyone: The application will be installed for all users.
Just
me:
The application will only be installed for the current user.
– Continued on next page –