SCD-XE800
SCD-XE800
13
13
M a n u a l A d j u s t
1 . T r a c k B a l a n c e A d j u s t :
2 . T r a c k G a i n A d j u s t :
3 . F o c u s B a l a n c e A d j u s t :
4 . F o c u s G a i n A d j u s t :
5 . E q B o o s t A d j u s t :
6 . I o p : x x
7 . T R V . L e v e l :
8 . S c u r v e ( F E ) L e v e l :
9 . R F L ( P I ) L e v e l :
0 . M I R R T i m e :
[
V
] [
v
] C h a n g e V a l u e
[ R E T U R N ] R e t u r n t o p r e v i o u s m e n u
5. Convert data from hexadecimal to decimal by using conver-
sion table.
6. If the value is smaller than 93 (decimal), then it is OK. How-
ever if the value is higher than 93, then BU (base unit) is defec-
tive and need to be change.
7. Press the [
O
RETURN] button on the remote commander to
return to previous menu.
8. Press the [0] button on the remote commander to return to the
top menu of Remocon Diagnosis Menu.
9. Disconnect the power cord to turn off.
Note:
Don’t press the [
?/1
] button when to release from this mode. Nec-
essarily disconnect the power cord. The set doesn’t operate when
turning off power with [
?/1
] button of the set.
4. Checking Emergency History
To check the emergency history, please follow the following pro-
cedure.
Procedure:
1. From the top menu of Remocon Diagnosis Menu, select “3.
Emergency History” by pressing the [3] button on the remote
commander. The following screen appears on the on-screen
display.
E m g . H i s t o r y C h e c k
L a s e r H o u r s C D 9 9 9 h 5 9 m i n
D V D 0 h 0 m i n
0 1 . 0 1 0 5 0 4 0 4 0 0 9 2 4 6 0 0
0 0 0 0 0 0 0 0 0 0 0 0 2 3 4 5
0 2 . 0 2 0 2 0 1 0 1 0 0 A 9 4 B 0 0
0 0 0 0 0 0 0 0 0 0 0 0 2 3 4 5
[ N e x t ] N e x t p a g e [ P r e v ] P r e v p a g e
[ 0 ] R e t u r n t o T o p M e n u
2. You can check the total time when the laser is turned on during
playback of Super Audio CD and CD from the above menu.
The maximum time, which can be displayed are 999h 59min.
3. You can check the error code of latest 10 emergency history
from the above menu. To view the previous or next page of
emergency history, press the [
.
] or [
>
] button on the re-
mote commander.
The error code consists of three kinds of error codes.
A. Error code
E x a m p l e o f E r r o r c o d e
0 1 . 0 1 0 5 0 4 0 4 0 0 9 2 4 6 0 0
0 0 0 0 0 0 0 0 0 0 0 0 2 3 4 5
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
B. Parameter of error code
This is the detail of error code.
E x a m p l e o f E r r o r c o d e
0 1 . 0 1 0 5 0 4 0 4 0 0 9 2 4 6 0 0
0 0 0 0 0 0 0 0 0 0 0 0 2 3 4 5
C. Time of error code
This is the laser time when an error occurred.
E x a m p l e o f E r r o r c o d e
0 1 . 0 1 0 5 0 4 0 4 0 0 9 2 4 6 0 0
0 0 0 0 0 0 0 0 0 0 0 0 2 3 4 5
To Clear Laser Hours and Emergency History
Perform Step 6. for EEPROM CLEAR of SERVICE MODE (1).
Note:
You will not be able to clear only one of either Laser Hours or Emer-
gency History. When EEPROM CLEAR is run, all content will be
deleted.
V e r s i o n i n f o r m a t i o n
I n i t i a l i z e a l l d a t a . . .
C o m p l e t e !
[ 0 ] R e t u r n t o T o p M e n u
E m g . H i s t o r y C h e c k
L a s e r H o u r s C D 0 h 0 m i n
D V D 0 h 0 m i n
0 1 . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 2 . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
[ N e x t ] N e x t p a g e [ P r e v ] P r e v p a g e
[ 0 ] R e t u r n t o T o p M e n u
To Execute the Initialize Setup Data
Procedure:
1. Press the [MENU] button on the remote commander and then
press the [CLEAR] button on the remote commander. The fol-
lowing screen appears on the on-screen display.
E m g . H i s t o r y C h e c k
L a s e r H o u r s C D 9 9 9 h 5 9 m i n
D V D 0 h 0 m i n
I n i t i a l i z e s e t u p d a t a . . .
[ N e x t ] N e x t p a g e [ P r e v ] P r e v p a g e
[ 0 ] R e t u r n t o T o p M e n u
2. The screen after a while returns to former display.
To Return to the Top Menu of Remocon Diagnosis
Menu
Press the [0] button on the remote commander.
5. Checking Version Information
To check the version information, please follow the following pro-
cedure.
Procedure:
1. From the top menu of Remocon Diagnosis Menu, select “4.
Version Information” by pressing the [4] button on the remote
commander. The following screen appears on the on-screen
display.
V e r s i o n i n f o r m a t i o n
F i r m ( M a i n ) : V e r . X . X X X X
F i r m ( S u b ) : X X . X X
R I S C : X X X X X X
8 0 3 2 : X X X X X X
A u d i o D S P : X X . X X . X X . X X
S e r v o D S P : X X . X X . X X . X X
[ 0 ] R e t u r n t o T o p M e n u
2. To return to the top menu of Remocon Diagnosis Menu, press
the [0] on the remote commander.
Summary of Contents for SCD-XE800
Page 4: ... Bottom view ...
Page 6: ...SCD XE800 2 3 POWER BOARD 2 4 PANEL LOADING 6 ...
Page 7: ...SCD XE800 2 5 FRONT PANEL BLOCK 2 6 CD MECHANISM DECK BLOCK CDM66F1 DVBU101 Note 1 ß 7 ...
Page 8: ......
Page 9: ...SCD XE800 2 9 BASE UNIT 2 10 OPTICAL PICK UP BLOCK KHM 313CAB 9 ...
Page 14: ......
Page 15: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 37: ...SCD XE800 5 2 CHASSIS SECTION 37 ...
Page 38: ...SCD XE800 5 3 MECHANISM DECK SECTION CDM66F1 DVBU101 38 ...