![Sony SAL50M28 - 50mm f/2.8 Macro Lens Service Manual Download Page 53](http://html.mh-extra.com/html/sony/sal50m28-50mm-f-2-8-macro-lens/sal50m28-50mm-f-2-8-macro-lens_service-manual_394191053.webp)
4-10
SAL50M28 (MACRO 2.8/50) (50mm F2.8 Macro)
2)
Attach the checking lens to the lens test projector, and set the equipments as shown in Fig.4-3-2.
3)
Turn the fan switch of the lens test projector to ON, then turn the lamp switch to ON.
Fig.4-3-2
4)
Turn the focus ring of the checking lens until the chart image projected on the screen is the sharpest at the center (y’=0).
5)
Set the plane mirror to the center of the projected image (y’= 0), and adjust the projector position so that the mirror reflects the light
to the center of the lens.
Distance
Lens test projector
Chart
Fan switch
Lamp switch
Plane mirror
Screen
A-mount attachment
Checking lens
F
L