54
Troubleshooting
App
end
ix
Memory status messages
The following warning messages appear depending on the
wear or usage of the memory. Using memory repeatedly
gradually increases the possibility that errors will occur
during recording and playback. When any of the following
messages appear, it is time to replace with new memory.
Specifically, if the “CONDITION x BAD” message
appears, it is best to replace with new memory as soon as
possible.
To clear a warning message
1
Display the Warning tab of the Maintenance screen of
the web menu.
2
Select [Warning Cancel].
3
Place a check mark in the messages whose settings you
want to change.
4
When finished, click the [OK] button.
For details, refer to the Service Manual.
Displaying the error log
You can check up to 99 detected error messages and
warning messages on the [Log] tab of the [Maintenance]
screen. You can also export the log to a file.
The error and warning messages are displayed in [Error/
Warning Table] on the [Maintenance] screen > [Log] tab.
To export the error log to a file
1
Click the [Log] tab on the [Maintenance] screen.
2
Click the [Create Error Log] button.
3
Right-click [Download Log File] and save the file.
The [Create Command Log 1/2] button and [Create
Storage Log 1/2] button are for maintenance use.
Code
Indication
Description
C10101
SLOT Mx CONDITION1 DOUBTFUL
(M1 COND1 DBT)
The number of errors when writing/reading is becoming larger.
Although all errors can be corrected, it is recommended that
you replace with new memory.
C10201
SLOT Mx CONDITION1 BAD
(M1 COND1 BAD)
The number of errors when writing/reading has become
extremely large.
Although all errors can be corrected, it is strongly
recommended that you replace with new memory.
C10301
SLOT Mx CONDITION2 DOUBTFUL
(M1 COND2 DBT)
The number of memory repetitive operations has become
large.
Although there is currently no problem, it is recommended that
you replace with new memory.
C10401
SLOT Mx CONDITION2 BAD
(M1 COND2 BAD)
The number of memory repetitive operations has become
extremely large.
Although there is currently no problem, it is strongly
recommended that you replace with new memory.
C10501
SLOT Mx CONDITION3 DOUBTFUL
(M1 COND3 DBT)
The swap space used to replace bad memory cells is
becoming smaller.
Although there is currently no problem, it is recommended that
you replace with new memory.
C10601
SLOT Mx CONDITION3 BAD
(M1 COND3 BAD)
The swap space used to replace bad memory cells has been
exhausted.
Although playback is still available, recording is no longer
possible.
It is strongly recommended that you replace with new memory.
Note
Summary of Contents for PWS-4500
Page 1: ...MULTI PORT AV STORAGE UNIT PWS 4500 OPERATION MANUAL English 1st Edition Revised 5 ...
Page 23: ...23 System Screen Chapter 4 Web Menu Remote tab Makes settings related to remote control ...
Page 33: ...33 Port Screen Chapter 4 Web Menu For output ports ...
Page 63: ...Sony Corporation PWS 4500 SYL 4 589 925 16 1 2015 ...