background image

1-1 (E)

PWS-110RX1

1-1. Installation 

Procedure

The following flowchart shows the installation procedure 
of the unit.
For details of each work, refer to the relevant section.
The Operation Manual is also required for the items
marked with an asterisk (

*

).

1-3. Operating Environment and Installation Space
1-4. Power Supply

Determination of

installation place

Start

End

Unpacking

1-5. Installing an Optional Power Unit

(This process is not necessary if you don't install an optional power unit.)

1-6-3. Mounting to Rack (M5 Screw Holes)
            Refer to the Installation Manual for RMM-10.
           (This process is not necessary if you don't mount this unit into a rack.)
1-6-4. Mounting to Rack (Square Holes)
           (This process is not necessary if you don't mount this unit into a rack.)

1-6-5. Installing the Front Panel

1-7. Connector Input/Output Signals

1-8. Connectors and Cables

Check the operation of the unit depending on the configuration of the system.

1-6-1. Part Required
1-6-2. Removing the Front Panel

 Connection

 Operation check

Installing an optional power unit

Installing the main unit to the rack

Installing the front panel

Removing the front panel

Section 1

Installation

1-2. Accessories

.

 Operation Manual 

(1)

.

  Installation Manual (this manual) 

(1)

.

 Operation Guide 

(1)

.

  Screws for Rack Mount 

(4)

Summary of Contents for PWS-110RX1

Page 1: ...NETWORK RX STATION PWS 110RX1 OPTIONAL POWER SUPPLY PWSK 101 INSTALLATION MANUAL 1st Edition Serial No 120001 and Higher PWS 110RX1 SY ...

Page 2: ...r Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin de réduire les risques de décharge électrique d incendie ou de blessure n effectuer que les réparations indiquées dans le mode d emploi à moins d...

Page 3: ...of the equipment refer to the specifications of the Operation Manual 6 When performing the installation keep the following space away from walls in order to obtain proper exhaust and radiation of heat Right Left 4 cm 1 6 inches or more Rear 10 cm 3 9 inches or more 設置時には 通気やサービス性を考慮して設置スペース を確保してください ファンの排気部 リアパネル面 右側面後ろ側 トッ プパネル後ろ側 や通気孔 フロントパネル面 左側 面フロント側 をふさがない 通気のために セット周辺に空間をあける 作業エリアを確保するため セ...

Page 4: ......

Page 5: ...wer Supply 1 4 E 1 4 1 Power Supply Specifications 1 4 E 1 4 2 Recommended Power Cord 1 4 E 1 5 Installing an Optional Power Unit 1 5 E 1 6 Rack Mounting 1 6 E 1 6 1 Parts Required 1 7 E 1 6 2 Removing the Front Panel 1 8 E 1 6 3 Mounting to Rack M5 Screw Holes 1 8 E 1 6 4 Mounting to Rack Square Holes 1 8 E 1 6 5 Installing the Front Panel 1 10 E 1 7 Connector Input Output Signals 1 11 E 1 8 Conn...

Page 6: ...it Service Manual Available on request This manual describes service overview error messages periodic maintenance and inspection replacement of main parts and so on of the unit to provide information required for block level service Installation manual for RMM 10 Supplied with RMM 10 This is necessary to install the unit to a 19 inch equipment rack Trademarks Trademarks and registered trademarks d...

Page 7: ... to the Installation Manual for RMM 10 This process is not necessary if you don t mount this unit into a rack 1 6 4 Mounting to Rack Square Holes This process is not necessary if you don t mount this unit into a rack 1 6 5 Installing the Front Panel 1 7 Connector Input Output Signals 1 8 Connectors and Cables Check the operation of the unit depending on the configuration of the system 1 6 1 Part R...

Page 8: ...ted installation places Places exposed to direct sunlight or intense light Places near a heat source Dusty places or places subject to constant vibration Places in strong magnetic field Places subject to much electrical noise Places where electrostatic noise is likely to be generated Places where specified installation space cannot be provided Refer to 1 3 2 Installation Space Sealed places Maximu...

Page 9: ...rs or more of space above the unit is recommended for service operation 482 43 6 7 22 500 162 5 Unit mm 115 5 115 5 440 15 3 Mass of this unit not including option approx 9 8 kg Moreover an air flow that is effective in cooling the unit is essential If the ventilation is not enough the unit may be damaged because of an increase of the internal tempera ture n This unit is air cooled by the fans The...

Page 10: ... of the AC power supply on the supply side may trip or the unit may malfunction 1 4 2 Recommended Power Cord This unit does not come with a power cord To get a power cord please contact your local Sony Sales Office Service Center w Use the approved Power Cord 3 core mains lead Appli ance Connector Plug with earthing contacts that con forms to the safety regulations of each country if appli cable U...

Page 11: ...he rear panel power Rear panel power assembly Rear panel power Blank panel power B3 8 B3 8 3 Insert the power unit n Make sure that the power unit has been locked after the insertion The power unit cannot be drawn out by pulling the handle without pulling up the lever Power unit 4 Align the hole to the boss attach the rear panel power and then tighten the four screws B3 x 8 n First tighten the scr...

Page 12: ...your back Use the specified rack mount kit The use of other kit of low strength may drop the unit and cause the risk of injury Fix the rack to the floor When the rack turns over with the heaviness of the unit it causes the death and the serious injury After rack mounting fix the unit to the rack securely If the screws of rack angle are not fastened the unit may slip down and dropped from the rack ...

Page 13: ...ack bracket 2 pcs Rack mount adaptor right 1 pc Including screw B4 x 6 7 682 560 09 2 pcs Rack mount adaptor left 1 pc Including screw B4 x 6 7 682 560 09 2 pcs Rack bracket attachment screw B4 x 6 7 682 560 09 6 pcs Adaptor attachment screw B4 x 10 7 682 560 10 6 pcs Screws for Rack Mount Screw for rack mount B5 x 12 7 682 576 04 4 pcs t These parts are supplied with this unit Parts for square ho...

Page 14: ...s at the tightening torque below Tightening torque 120 x 10 _2 N m 12 2 kgf cm 1 Attach the rack brackets in the side panels of the unit with the specified six screws B4 x 6 Rack bracket Rack bracket B4 6 B4 6 2 Remove the release paper of the plate nut M5 and stick the plate nut to the front of the adaptor n Align the adaptor with the plate nut M5 at the top edges and at the lateral edges Make su...

Page 15: ...ont Positioning plate Bosses Bosses Square Holes B4 10 B4 10 Positioning plate Viewed from inside the rack angle Rear 5 Tighten the length adjustment screws B4 x 6 two screws for each bracket which are loosened in step 3 6 Align the bent section of the each rack bracket on the side panels of the unit to the rail and then slide the unit backward t Each rack bracket covers the rails as shown in the ...

Page 16: ... the rail or trouble attaching the front panel to the unit adjust the position of positioning plate Positioning plate 1 6 5 Installing the Front Panel Attach the front panel to the main unit and tighten the two anti drop screws Anti drop screw Front panel Anti drop screw ...

Page 17: ...tive 3 SDI1 to 4 BNC 4 Impedance 75 Z 1 Voltage 0 8 V p p HD SMPTE ST 292 1 compatible SD SMPTE ST 259 compatible 4 USB Super Speed USB USB 3 0 Type A 4 Among four right lower connector supports to the power supply 900 mA Others do not support to the power supply 5 LAN1 2 RJ 45 8 pin 2 1000BASE T 100BASE TX 6 HDMI Type A 1 HDMI Ver 1 4a 1920 x 1200 maximum resolution 60 Hz 7 DisplayPort This conne...

Page 18: ...t No Remarks REF IN BNC 75 Z MALE 1 569 370 12 _ SDI 1 to 4 BNC 75 Z MALE 1 569 370 12 _ HDMI HDMI type A The HDMI cable use a product made in Sony Recommended HIGH SPEED HDMI cable DLC HE20XF 2 m _ _ USB Use a cable for super speed USB _ _ SYSTEM BNC 75 Ω MALE 1 569 370 12 _ LAN1 2 Network cable STP cable is recommended _ Commercially available STP Shielded Twisted Pair ...

Page 19: ...Onboard Switches 2 1 1 Settings of Onboard Switch n Be sure not to change the default settings of switches on the board Board Ref No Factory Setting Knob position MB 1204 S800 1 2 O N 3 4 5 6 7 8 S2201 CFG 1 2 O N 3 4 HPR 48 S4002 1 2 O N 3 4 5 6 7 8 ...

Page 20: ......

Page 21: ......

Page 22: ...Sony Corporation PWS 110RX1 SY J E 4 596 995 01 Printed in Japan 2016 8 08 2016 ...

Reviews: