1-6 (E)
PWS-110RX1
1-6. Rack
Mounting
This process is not necessary if you do not mount this unit
into a rack.
This unit can be mounted to a 19-inch rack conforming to
the ANSI/EIA-310-D standard, which meets the following
conditions.
1. Hole pitch:
Universal pitch
2. Mounting hole: M5 screw hole or square hole (
□
9.2 to
□
10 mm)
3. Holes of the front and rear mount angles meet the
conditions 1 and 2 above.
4. The inner distance between these mount angles is
within a range of 600 to 750 mm.
5. A space of at least 10 mm is provided from the inner
end of each mount angle to the right and left sides
outward.
Rack unit
44.45 mm
Inside dimension
450 mm min.
Mounting dimension
465 mm ±1.6
Mounting hole
0RUVTXDUHKROHƑWRƑPP
15.875 mm
15.875 mm
This illustration is an example of M5 screw hole.
PP
Front View
Inner distance 600 to 750 mm
Inner end of mount angle
Inner end of mount angle
Top View
Inside dimension
450 mm min.
10 mm or greater
10 mm or greater
Mount angles
Mount angles
Clearance
Front
Rear
Be sure to mount this unit into a rack accurately following
the procedure and notes mentioned below.
w
.
To prevent toppling over the rack, fix it on the horizontal
and firm floor securely with bolts or some anchoring
materials.
c
.
More than two person for rack mount.
If you perform rack mount alone, you can hurt your back.
.
Use the specified rack mount kit.
The use of other kit of low strength may drop the unit
and cause the risk of injury.
.
Fix the rack to the floor.
When the rack turns over with the heaviness of the unit,
it causes the death and the serious injury.
.
After rack mounting, fix the unit to the rack securely.
If the screws of rack angle are not fastened, the unit may
slip down and dropped from the rack, and you may get
injured. After rack mounting, be sure to tighten the
screws.
.
Entrust the installation to a specialized contractor.
When mounting the unit to the rack, confirm the enough
strength, if not, the unit may be dropped and you may get
injured.
Installation to the rack, entrust to a specialized contrac-
tor.
n
.
When other equipment with built-in hard disk drive is
already mounted in the same rack to which this unit is
going to be mounted. Turn off the power of the equip-
ment before mounting this unit.
.
Do not install the unit to the rack without exterior parts.
.
Cables connected to the connector panel must be long
enough to pull out the unit from the rack.
.
To suppress the internal temperature rise of the unit,
reserve a space of 4 cm or more on both sides and 10 cm
or more on the rear side between the rack and the unit.
(Refer to Fig. 1)
To ensure proper airflow, keep at least one of the four
spaces (up, rear, right, and left) at the rear of the unit so
as not to block airflow. (Refer to Fig. 2)
.
Adjust the temperature inside the rack within the range
of the unit’s operating temperature.
(Refer to Section 1-3)